1.
Braz Dent J ; 34(3): 66-72, 2023.
Article in English | MEDLINE | ID: mdl-37466527

ABSTRACT

The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of non-decalcified histological sections and evaluation of the bone implant contact (% BIC) as well as the fraction of bone tissue area between the implant threads (% BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) and % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.


Subject(s)
Dental Implants , Osseointegration , Animals , Rabbits , Surface Properties , Hydrophobic and Hydrophilic Interactions , Bone and Bones , Titanium , Torque
2.
Braz. dent. j ; 34(3): 66-72, May-June 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1447593

ABSTRACT

Abstract The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of non-decalcified histological sections and evaluation of the bone implant contact (% BIC) as well as the fraction of bone tissue area between the implant threads (% BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) and % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.


Resumo O objetivo deste estudo foi avaliar a osseointegração de uma superfície hidrofílica (jateamento + ataque ácido + imersão em solução isotônica) em comparação com uma superfície controle (jateamento + ataque ácido) usando um modelo experimental de osso de baixa densidade. Para realizar o estudo, 24 coelhos foram submetidos a instalação de 4 implantes bilateralmente no osso ilíaco: 2 implantes com superfície controle e 2 implantes com superfície hidrofílica. Os coelhos foram eutanasiados com 2, 4 e 8 semanas após a instalação dos implantes. Após a eutanásia, um implante de cada superfície foi usado para avaliar o torque de remoção, e o outro implante foi utilizado para execução de cortes histológicos não descalcificados e avaliação de contato osso implante (% BIC) bem como a fração da área tecido ósseo entre as roscas do implante (% BBT). Os implantes com superfície hidrofílica apresentaram maior %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) e % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) no período de 2 semanas. Além disso, a superfície hidrofílica apresentou maior torque de remoção no período de 8 semana (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implantes com a superfície hidrofílica apresentaram aceleração no processo de osseointregração, culminando em melhor estabilidade secundária no osso de baixa densidade em relação a implantes com superfície controle.

3.
Clin Oral Implants Res ; 32(6): 767-775, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33749041

ABSTRACT

OBJECTIVES: To assess the influence of two different implant surfaces on osseointegration in maxillary sinuses of rabbits previously grafted with deproteinized bovine bone (DBB) associated or not with fresh bone marrow (BM). MATERIAL AND METHODS: Sixteen New Zealand albino rabbits (males, 3.5/4.5 kg and 9-12 months old) were randomly divided into two groups with 8 rabbits each, according to the type of association of biomaterials used to fill the animals' maxillary sinuses: DBB (Deproteinized Bovine Bone) and DBB/BM (Deproteinized bovine bone associated with fresh autologous bone marrow). Ninety (90) days following the grafting procedure, the animals received implants in the area with two different microstructures (SA-Sandblasting + acid attack and SA-H-Sandblasting + acid attack + immersion in 0.9% sodium chloride isotonic solution). All rabbits were euthanized 90 days after implant placement. The microtomographic analysis was performed to verify the number of mineralized tissues around the implants throughout their length (%BV/TV), while the histomorphometric analysis was performed to verify the percentage of bone-implant contact around the implants throughout their length (%BIC). RESULTS: We observed no differences in the quantity for %BV/TV (DBB-SA:33.25 ± 19.67; DBB-SA-H:35.15 ± 22.17; DBB/BM-SA:39.71 ± 24.21; DBB/BM-SA-H:36.40 ± 23.07) and %BIC (DBB-SA:58.94 ± 24.37; DBB-SA-H:52.52 ± 24.36; DBB/BM-SA: 61.66 ± 14.60; DBB/BM-SA-H: 64.06 ± 23.30) between the groups assessed. CONCLUSIONS: The addition of BM and the type of surface did not influence the osseointegration of implants installed in areas grafted with sintered deproteinized bovine bone at high temperatures in the late period assessed.


Subject(s)
Bone Substitutes , Dental Implants , Animals , Bone Marrow , Cattle , Male , Maxillary Sinus , Osseointegration , Rabbits
4.
Materials (Basel) ; 13(7)2020 Mar 26.
Article in English | MEDLINE | ID: mdl-32224982

ABSTRACT

The objective of this study was to assess the primary stability and the osseointegration process in implants with different macrostructures (Cylindrical vs. Hybrid Conical) in rabbit tibiae. Twenty-four (24) rabbits were used, divided into 3 experimental periods (2, 4 and 8 weeks) with 8 animals each. Each animal bilaterally received 2 implants from each group in the tibial metaphysis: Cylindrical Implant (CI) and Hybrid Conical Implant (HCI). All implants were assessed for insertion torque. After the experimental periods, one of the implants in each group was submitted to the removal counter-torque test and descriptive histological analysis while the other implant was used for microtomographic and histometric analysis (%Bone-Implant Contact). HCI implants showed higher insertion torque (32.93 ± 10.61 Ncm vs. 27.99 ± 7.80 Ncm) and higher % of bone-implant contact in the 8-week period (79.08 ± 11.31% vs. 59.72 ± 11.29%) than CI implants. However, CI implants showed higher values of removal counter-torque than HCI implants in the 8-week period (91.05 ± 9.32 Ncm vs. 68.62 ± 13.70 Ncm). There were no differences between groups regarding microtomographic data. It can be concluded that HCI implants showed greater insertion torque and bone-implant contact in relation to CI implants in the period of 8 weeks when installed in cortical bone of rabbits.

SELECTION OF CITATIONS
SEARCH DETAIL
...