Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-35055629

ABSTRACT

Dengue mortality remains high despite monitoring against warning signs (WS). The associations of WS at febrile phase (FP) and hemorrhage at defervescence with the levels and kinetics of ROTEM, platelet count, cortisol, and ferritin were analyzed. Patients with confirmed dengue serology and WS in two centers were screened (n = 275) and 62 eligible patients were recruited prospectively over 9 months. "Vomiting" was the commonest WS (62.9%), with shortened clotting time (CT) INTEM (p = 0.01). "Hematocrit increase" showed significant prolonged CT INTEM, EXTEM, and FIBTEM (p < 0.05). "Platelet decrease" showed reduced platelet function and reduced clot amplitude at 10 min (A10) and maximum clot firmness (MCF) in INTEM and EXTEM (p < 0.001). The kinetics were reduced in platelet count, CT EXTEM, and cortisol (p < 0.05) but increased in CT INTEM (p = 0.03). At FP, "vomiting", "hematocrit increase", and "platelet decrease" demonstrated impaired CT, clot strengths A10/MCF and platelet functions. Majority (60/62, 96.7%) had non-severe outcomes, consistent with increase in cortisol kinetics. In conclusion, "vomiting", "hematocrit increase" and "platelet decrease" at FP correlated with ROTEM. No conclusion could be made further regarding ferritin and cortisol. Larger study is required to study "hematocrit increase" with ROTEM as a potential marker for hemorrhage.


Subject(s)
Dengue , Hydrocortisone , Blood Coagulation Tests , Dengue/diagnosis , Humans , Platelet Count , Thrombelastography
2.
Sensors (Basel) ; 18(3)2018 Feb 26.
Article in English | MEDLINE | ID: mdl-29495352

ABSTRACT

A tri-enzyme system consisting of choline kinase/choline oxidase/horseradish peroxidase was used in the rapid and specific determination of the biomarker for bacterial sepsis infection, secretory phospholipase Group 2-IIA (sPLA2-IIA). These enzymes were individually immobilized onto the acrylic microspheres via succinimide groups for the preparation of an electrochemical biosensor. The reaction of sPLA2-IIA with its substrate initiated a cascading enzymatic reaction in the tri-enzyme system that led to the final production of hydrogen peroxide, which presence was indicated by the redox characteristics of potassium ferricyanide, K3Fe(CN)6. An amperometric biosensor based on enzyme conjugated acrylic microspheres and gold nanoparticles composite coated onto a carbon-paste screen printed electrode (SPE) was fabricated and the current measurement was performed at a low potential of 0.20 V. This enzymatic biosensor gave a linear range 0.01-100 ng/mL (R² = 0.98304) with a detection limit recorded at 5 × 10-3 ng/mL towards sPLA2-IIA. Moreover, the biosensor showed good reproducibility (relative standard deviation (RSD) of 3.04% (n = 5). The biosensor response was reliable up to 25 days of storage at 4 °C. Analysis of human serum samples for sPLA2-IIA indicated that the biosensor has potential for rapid bacterial sepsis diagnosis in hospital emergency department.


Subject(s)
Biosensing Techniques , Biomarkers , Electrodes , Enzymes, Immobilized , Gold , Humans , Hydrogen Peroxide , Metal Nanoparticles , Phospholipases , Reproducibility of Results , Sepsis
SELECTION OF CITATIONS
SEARCH DETAIL
...