Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Endovasc Ther ; 23(5): 762-72, 2016 10.
Article in English | MEDLINE | ID: mdl-27280802

ABSTRACT

PURPOSE: To evaluate midterm outcomes of endovascular repair of types II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients unsuitable for open surgery or fenestrated stent-grafts. METHODS: In the prospective, multicenter, nonrandomized STRATO trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (mean age 75.8 years; 19 men) with Crawford type II and III TAAA (mean diameter 6.5 cm) were implanted between April 2010 and February 2011. Outcomes included all-cause mortality and stable aneurysm thrombosis with associated branch vessel patency. RESULTS: Through 36 months, there were 7 deaths (none confirmed as aneurysm-related), and no cases of spinal cord injury, device migration or fracture, or respiratory, renal, or peripheral complications. Three patients were lost to follow-up and 2 devices were explanted. The device was patent in the 11 remaining patients at 3 years. Stable aneurysm thrombosis was achieved for 15 of 20 patients at 12 months, 12 of 13 at 24 months, and 10 of 11 at 36 months. The rate of branch patency was 96% at 12 months (primary patency), 100% at 24 months, and 97% at 36 months. Nine patients suffered from endoleaks (attachment site or device overlap); 9 patients underwent 11 reinterventions (3 surgical). Maximum aneurysm diameter was stable for 18 of 20 patients at 12 months, 11 of 13 at 24 months, and 9 of 11 at 36 months. For 10 patients with computed tomography at 36 months, the mean ratio of aneurysm flow volume to total volume had decreased by 83%; the mean ratio of thrombus volume to total volume increased by 159%. CONCLUSION: Through 3 years, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , France , Humans , Kaplan-Meier Estimate , Male , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Regional Blood Flow , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
2.
J Endovasc Ther ; 21(1): 85-95, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24502488

ABSTRACT

PURPOSE: To evaluate endovascular repair of type II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients with contraindications for open surgery and fenestrated stent-grafts. METHODS: In this prospective, multicenter, nonrandomized trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (19 men; mean age 75.8 years) with Crawford type II (43.5%) and III (56.5%) TAAA (mean diameter 6.5 cm) were treated with the MFM between April 2010 and February 2011. The primary efficacy outcome measure was stable aneurysm thrombosis with associated branch vessel patency at 12 months; the primary safety endpoint was 30-day and 12-month all-cause mortality. RESULTS: The rate of technical success was 100%. In 20 patients with computed tomography scans at 12 months, the primary efficacy outcome was met in 15 patients. The rate of primary patency of covered branch vessels was 96% (53/55); 1 patient with 2 occluded visceral branches underwent successful surgical reintervention. Endoleaks were identified in 5 patients (3 attachment site and 2 at device overlap), 4 of whom underwent reintervention (3 additional MFMs and 1 stent-graft implanted). At 12 months, aneurysm diameter was stable in 18 of 20 patients; the mean ratio of residual aneurysm flow volume to total volume had decreased by 28.9%, and the mean ratio of thrombus volume to total lumen volume had increased by 21.3% (n=17). There were no cases of device migration, loss of device integrity, spinal cord ischemia, or aneurysm rupture. CONCLUSION: At 1 year, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency. Follow-up is ongoing.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnosis , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Female , France , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/surgery , Humans , Male , Middle Aged , Prosthesis Design , Regional Blood Flow , Reoperation , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...