Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 312
Filter
1.
J Invasive Cardiol ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38718281

ABSTRACT

A 73-year-old man with a history of hypertension, hyperlipidemia, and obesity presented for cardiovascular evaluation. He was experiencing mild fatigue and dyspnea on exertion. Transthoracic echocardiogram (TTE) showed right ventricular dilation, which was otherwise unremarkable.

2.
J Am Coll Cardiol ; 83(19): 1917-1935, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38719371

ABSTRACT

Ventricular aneurysm represents a rare complication of transmural acute myocardial infarction, although other cardiac, congenital, or metabolic diseases may also predispose to such condition. Ventricular expansion includes all the cardiac layers, usually with a large segment involved. Adverse events include recurrent angina, reduced ventricular stroke volume with congestive heart failure, mitral regurgitation, thromboembolism, and ventricular arrhythmias. Multimodality imaging is paramount to provide comprehensive assessment, allowing for appropriate therapeutic decision-making. When indicated, surgical intervention remains the gold standard, although additional therapy (heart failure, anticoagulation, and advanced antiarrhythmic treatment) might be required. However, the STICH (Surgical Treatment for Ischemic Heart Failure) trial did not show any advantage from adding surgical ventricular reconstruction to coronary artery bypass surgery in terms of survival, rehospitalization or symptoms, compared with revascularization alone. Finally, implantable cardiac defibrillator may reduce the risk of fatal arrhythmias.


Subject(s)
Heart Aneurysm , Myocardial Infarction , Humans , Heart Aneurysm/etiology , Heart Aneurysm/surgery , Myocardial Infarction/etiology , Heart Ventricles/diagnostic imaging
3.
J Invasive Cardiol ; 2024 May 21.
Article in English | MEDLINE | ID: mdl-38776477

ABSTRACT

A 93-year-old woman with symptomatic severe aortic stenosis and normal biventricular function was referred for transcatheter aortic valve replacement (TAVR) evaluation. Cardiac computed tomography revealed safe coronary heights and multiple large calcified mobile mass-like structures attached to the aortic valve (AV), confirmed also by transesophageal echocardiography, which were thought to be prominent Lambl's excrescences.

4.
Article in English | MEDLINE | ID: mdl-38749898

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has undergone significant advances in recent years, with the development of improved pre-planning tools and devices. These advances have led to a reduction in the rate of paravalvular leak (PVL), a complication that is associated with poor outcomes even when mild. As some centers around the world are moving to solely fluoroscopy-focused implantation, we aimed to describe the clinical impact of intra-procedural transthoracic echocardiography (TTE) during TAVI in a high volume hospital. METHODS: Observational study during a 3-month period. A limited TTE examination was performed immediately after deployment to assess the existence of PVL and grade its severity. Complete TTE was performed a day after the procedure. In case of ≥mild PVL after valve deployment, a decision was made according to the severity of the PVL, patient anatomy and extent of annular calcification to preform balloon post-dilation. If done, an additional limited TTE was performed to assess possible complication and the degree of PVL post dilatation. RESULTS: 115 patient were included in the study. Intra-procedural TTE identified 16 patients (14 %) with at least mild PVL, three of them with moderate (3 %). Post balloon dilatation was performed in 10 patients (9 % of the cohort) with significant improvement in the degree of PVL. CONCLUSION: Intra-procedural TTE immediately after TAVI deployment can accurately identify PVL, allowing operators to perform post balloon dilatation with improvement in early echocardiographic results. Our findings support the routine use of TTE during procedures, without relying solely on fluoroscopy.

5.
J Invasive Cardiol ; 2024 May 23.
Article in English | MEDLINE | ID: mdl-38787923

ABSTRACT

An 83-year-old woman with symptomatic severe aortic stenosis was referred for transcatheter aortic valve replacement. Diagnostic left heart catheterization documented diffuse 3-vessel coronary artery disease.

6.
Article in English | MEDLINE | ID: mdl-38795109

ABSTRACT

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.

7.
J Am Coll Cardiol ; 83(18): 1779-1798, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38692829

ABSTRACT

Right ventricular infarction (RVI) complicates 50% of cases of acute inferior ST-segment elevation myocardial infarction, and is associated with high in-hospital morbidity and mortality. Ischemic right ventricular (RV) systolic dysfunction decreases left ventricular preload delivery, resulting in low-output hypotension with clear lungs, and disproportionate right heart failure. RV systolic performance is generated by left ventricular contractile contributions mediated by the septum. Augmented right atrial contraction optimizes RV performance, whereas very proximal occlusions induce right atrial ischemia exacerbating hemodynamic compromise. RVI is associated with vagal mediated bradyarrhythmias, both during acute occlusion and abruptly with reperfusion. The ischemic dilated RV is also prone to malignant ventricular arrhythmias. Nevertheless, RV is remarkably resistant to infarction. Reperfusion facilitates RV recovery, even after prolonged occlusion and in patients with severe shock. However, in some cases hemodynamic compromise persists, necessitating pharmacological and mechanical circulatory support with dedicated RV assist devices as a "bridge to recovery."


Subject(s)
Heart Ventricles , Ventricular Dysfunction, Right , Humans , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/etiology , Heart Ventricles/physiopathology , Myocardial Infarction/physiopathology
8.
Article in English | MEDLINE | ID: mdl-38687616

ABSTRACT

OBJECTIVES: The study developed framework that leverages an open-source Large Language Model (LLM) to enable clinicians to ask plain-language questions about a patient's entire echocardiogram report history. This approach is intended to streamline the extraction of clinical insights from multiple echocardiogram reports, particularly in patients with complex cardiac diseases, thereby enhancing both patient care and research efficiency. MATERIALS AND METHODS: Data from over 10 years were collected, comprising echocardiogram reports from patients with more than 10 echocardiograms on file at the Mount Sinai Health System. These reports were converted into a single document per patient for analysis, broken down into snippets and relevant snippets were retrieved using text similarity measures. The LLaMA-2 70B model was employed for analyzing the text using a specially crafted prompt. The model's performance was evaluated against ground-truth answers created by faculty cardiologists. RESULTS: The study analyzed 432 reports from 37 patients for a total of 100 question-answer pairs. The LLM correctly answered 90% questions, with accuracies of 83% for temporality, 93% for severity assessment, 84% for intervention identification, and 100% for diagnosis retrieval. Errors mainly stemmed from the LLM's inherent limitations, such as misinterpreting numbers or hallucinations. CONCLUSION: The study demonstrates the feasibility and effectiveness of using a local, open-source LLM for querying and interpreting echocardiogram report data. This approach offers a significant improvement over traditional keyword-based searches, enabling more contextually relevant and semantically accurate responses; in turn showing promise in enhancing clinical decision-making and research by facilitating more efficient access to complex patient data.

9.
Am J Cardiol ; 221: 84-93, 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38649128

ABSTRACT

A substantial number of patients may experience systemic inflammatory response syndrome (SIRS) and related adverse events after transcatheter aortic valve implantation and endovascular aortic aneurysm repair. Although a clear etiology has not been established, endothelial disruption and tissue-ischemic response secondary to the foreign material may represent the trigger events. A latency period (0 to 48 hours) may occur between the initial injury and onset of symptoms mirroring an initial local response followed by a systemic response. Clinical presentation can be mild or severe depending on external triggers and characteristics of the patient. Diagnosis is challenging because it simulates an infection, but lack of response to antibiotics, negative cultures are supportive of SIRS. Increased in-hospital stay, readmissions, major cardiovascular events, and reduced durability of the device used are the main complications. Treatment includes non-steroidal anti-inflammatory drugs or corticosteroids. In conclusion, further studies are warranted to fully explore pathophysiologic mechanisms underpinning SIRS and the possibility of enhancing device material immune compatibility to reduce the inflammatory reaction of the host tissue.

11.
J Invasive Cardiol ; 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38547048

ABSTRACT

We report the case of an 80-year-old woman with known quadricuspid aortic valve (QAV), severe aortic stenosis, and moderate-to-severe regurgitation who recently underwent a transcatheter aortic valve replacement (TAVR).

12.
Circ Cardiovasc Interv ; 17(3): e013766, 2024 03.
Article in English | MEDLINE | ID: mdl-38502723

ABSTRACT

BACKGROUND: Redo-transcatheter aortic valve replacement (TAVR) can pin the index transcatheter heart valve leaflets open leading to sinus sequestration and restricting coronary access. The impact of initial implant depth and commissural alignment on redo-TAVR feasibility is unclear. We sought to determine the feasibility of redo-TAVR and coronary access after SAPIEN 3 (S3) TAVR stratified by implant depth and commissural alignment. METHODS: Consecutive patients with native valve aortic stenosis were evaluated using multidetector computed tomography. S3 TAVR simulations were done at 3 implant depths, sizing per manufacturer recommendation and assuming nominal expansion in all cases. Redo-TAVR was deemed unfeasible based on valve-to-sinotubular junction distance and valve-to-sinus height <2 mm, while the neoskirt plane of the S3 transcatheter heart valve estimated coronary access feasibility. RESULTS: Overall, 1900 patients (mean age, 80.2±8 years; STS-PROM [Society of Thoracic Surgeons Predicted Risk of Operative Mortality], 3.4%) were included. Redo-TAVR feasibility reduced significantly at shallower initial S3 implant depths (2.3% at 80:20 versus 27.5% at 100:0, P<0.001). Larger S3 sizes reduced redo-TAVR feasibility, but only in patients with a 100:0 implant (P<0.001). Commissural alignment would render redo-TAVR feasible in all patients, assuming the utilization of leaflet modification techniques to reduce the neoskirt height. Coronary access following TAV-in-TAV was affected by both index S3 implant depth and size. CONCLUSIONS: This study highlights the critical impact of implant depth, commissural alignment, and transcatheter heart valve size in predicting redo-TAVR feasibility. These findings highlight the necessity for individualized preprocedural planning, considering both immediate results and long-term prospects for reintervention as TAVR is increasingly utilized in younger patients with aortic stenosis.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Feasibility Studies , Prosthesis Design , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Risk Factors
13.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38456886

ABSTRACT

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Subject(s)
Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Multidetector Computed Tomography
17.
Comput Biol Med ; 172: 108191, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38457932

ABSTRACT

Bicuspid aortic valve (BAV), the most common congenital heart disease, is prone to develop significant valvular dysfunction and aortic wall abnormalities such as ascending aortic aneurysm. Growing evidence has suggested that abnormal BAV hemodynamics could contribute to disease progression. In order to investigate BAV hemodynamics, we performed 3D patient-specific fluid-structure interaction (FSI) simulations with fully coupled blood flow dynamics and valve motion throughout the cardiac cycle. Results showed that the hemodynamics during systole can be characterized by a systolic jet and two counter-rotating recirculation vortices. At peak systole, the jet was usually eccentric, with asymmetric recirculation vortices and helical flow motion in the ascending aorta. The flow structure at peak systole was quantified using the vorticity, flow rate reversal ratio and local normalized helicity (LNH) at four locations from the aortic root to the ascending aorta. The systolic jet was evaluated with the peak velocity, normalized flow displacement, and jet angle. It was found that peak velocity and normalized flow displacement (rather than jet angle) gave a strong correlation with the vorticity and LNH in the ascending aorta, which suggests that these two metrics could be used for clinical noninvasive evaluation of abnormal blood flow patterns in BAV patients.


Subject(s)
Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Aortic Valve/abnormalities , Heart Valve Diseases/diagnostic imaging , Aorta , Hemodynamics/physiology
19.
Eur Heart J Cardiovasc Imaging ; 25(2): 267-277, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-37774491

ABSTRACT

AIMS: In patients with severe aortic stenosis (AS), low-flow low-gradient (LG) is a known predictor of worse outcomes. However, very LG may represent a distinct population with further cardiac dysfunction. It is unknown whether this population benefits from transcatheter aortic valve replacement (TAVR). We aimed to describe the patient characteristics and clinical outcomes of low-flow very LG severe AS. METHODS AND RESULTS: This single-centre study included all patients with low-flow severe AS between 2019 and 2021. Patients were divided into groups with very LG [mean pressure gradient (MPG) ≤ 20 mmHg], LG (20 < MPG < 40 mmHg), and high-gradient (HG) (MPG ≥ 40 mmHg). Composite endpoint of all-cause mortality and heart failure rehospitalization was compared. A total of 662 patients [very LG 130 (20%); LG 339 (51%); HG 193 (29%)] were included. Median follow-up was 12 months. Very LG cohort had a higher prevalence of comorbid conditions with lower left ventricular ejection fraction (45% vs. 57% vs. 60%; P < 0.001). There was a graded increase in the risk of composite endpoint in the lower MPG strata (P < 0.001). Among those who underwent TAVR, very LG was an independent predictor of the composite endpoint (adjusted HR 2.42 [1.29-4.55]). While LG and HG cohorts had decreased risk of composite endpoint after TAVR compared with conservative management, very LG was not associated with risk reduction (adjusted HR 0.69 [0.35-1.34]). CONCLUSION: Low-flow very LG severe AS represents a distinct population with significant comorbidities and worse outcomes. Further studies are needed to evaluate the short- and long-term benefits of TAVR in this population.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Severity of Illness Index
20.
Int J Cardiovasc Imaging ; 40(1): 81-82, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37983001

ABSTRACT

Leaflet thrombosis is usually an incidental finding and Cardiac CT is the gold standard for its diagnosis, but the classic features of hypoattenuation leaflet thickening (HALT) and hypoattenuation affecting motion (HAM) can also be seen on echocardiography and more specifically on trans-esophageal echocardiography. We describe a case of transcatheter aortic valve thrombosis where both the diagnosis and treatment were based exclusively on the echocardiographic evaluation, without the need of cardiac CT, with good outcome for the patient.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Predictive Value of Tests , Aortic Valve/surgery , Tomography, X-Ray Computed , Aortic Valve Stenosis/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...