Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Int Orthop ; 44(12): 2545-2551, 2020 12.
Article in English | MEDLINE | ID: mdl-33083903

ABSTRACT

BACKGROUND: The aims of our study were to compare the clinical, radiographic outcomes and survivals between second-generation metal-on-metal (Metasul) and ceramic-on-ceramic (Cerasul) bearings at a very long-term follow-up. METHODS: A prospective, randomized study was originally performed on a consecutive series of 250 cementless, 28-mm head and primary total hip arthroplasties between 1999 and 2002. For each bearing (Metasul or Cerasul), 125 THAs were initially included. All cases were evaluated both clinically and radiographically, and survival was assessed, considering revisions for aseptic loosening or for any reason as the end points for failure. RESULTS: At a mean 18-year follow-up, clinical and radiographic outcomes were similar. Harris Hip Score increased 30% in the Metasul group and 32% in the Cerasul group (p = 0.6). Survival free of aseptic loosening was higher for Cerasul (100%), than for Metasul (94% [CI 88-99.9]) (p = 0.04). Survival free of any revision was 91% ([CI 84-98%]) for Cerasul and 91% ([CI 84-98%]) for Metasul. Fractures of Cerasul insert occurred in four cases (3%) at a mean 12.5 ± 3.3 years (range, 6 to 17 years). CONCLUSION: At 18 years, Cerasul demonstrated higher survivorship than Metasul considering aseptic loosening as an end point. However, Cerasul liners had high rate of fracture because of its sandwich design (thin ceramic liner into polyethylene). These implants are no more available on the market.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Ceramics , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Prospective Studies , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome
2.
J Arthroplasty ; 28(2): 296-302, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22784488

ABSTRACT

The aims of our study were to compare metal-on-metal (Metasul) and ceramic-on-ceramic (Cerasul) bearings and to evaluate the clinical and radiographic results of these 2 different hard-on-hard bearings. We conducted a prospective, randomized study on a series of 250 cementless primary total hip arthroplasties. The prostheses were similar in all aspects except for the bearing surfaces: 50% of Metasul bearing and 50% of Cerasul bearing. All the patients were evaluated both clinically and radiographically. No patient was lost to follow-up. Clinical outcomes in both groups were similar. Considering aseptic loosening as the end point for failure, the 9-year survival rate was 100% for Cerasul and 98.4% for Metasul. Neither bearing outperformed the other both radiographically and clinically. The overall 9-year survival rate was 99.2% and 97.6% in the Cerasul and Metasul groups, respectively.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Joint/surgery , Hip Prosthesis , Joint Diseases/surgery , Aged , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Humans , Joint Diseases/diagnostic imaging , Male , Middle Aged , Prospective Studies , Radiography
3.
Foot Ankle Surg ; 15(4): 179-82, 2009.
Article in English | MEDLINE | ID: mdl-19840748

ABSTRACT

BACKGROUND: The public health cost impact of complex regional pain syndrome type I (CRPS I) is considerable in both emergency and scheduled orthopaedic surgery. We proposed to assess the effectiveness of vitamin C in prevention of CRPS I in foot and ankle surgery. METHODS: We carried out a "before-after" quasi-experimental study comparing two chronologically successive groups without (Group I: July 2002-June 2003) and with (Group II: July 2003-June 2004) preventive 1g daily vitamin C treatment. All patients having surgery on the foot or ankle were enrolled, with the exception of diabetic foot cases. Several factors were analysed: sex, age, type of pathology, history of CRPS I, psychological context, tourniquet time, and cast immobilisation time. RESULTS: 420 feet (392 patients) were included in the study: 185 in Group I, 235 in Group II. CRPS I occurred in 18 cases in Group I (9.6%) and 4 cases in Group II (1.7%) (p<10(-4)), with history of CRPS I as a significantly correlated factor (relative risk=10.4). The psychological context (anxio-depressive state) showed a (sub-significant) tendency to increase the risk of CRPS I (relative risk=2.6). CONCLUSION: Vitamin C has been shown to be effective in preventing CRPS I secondary to wrist fracture, but few data are available with respect to foot and ankle cases. The present study demonstrates the effectiveness of vitamin C in preventing CRPS I of the foot and ankle-a frequent complication in our control group (9.6%). The authors recommend preventive management by vitamin C.


Subject(s)
Ankle Injuries/surgery , Antioxidants/administration & dosage , Ascorbic Acid/administration & dosage , Foot Injuries/surgery , Orthopedic Procedures/adverse effects , Pain, Postoperative/prevention & control , Reflex Sympathetic Dystrophy/prevention & control , Adolescent , Adult , Aged , Dose-Response Relationship, Drug , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Reflex Sympathetic Dystrophy/etiology , Syndrome , Treatment Outcome , Young Adult
4.
J Arthroplasty ; 24(5): 710-5, 2009 Aug.
Article in English | MEDLINE | ID: mdl-18701251

ABSTRACT

Posterior cruciate ligament stretching after posterior cruciate ligament-retaining (CR) total knee arthroplasty (TKA) can lead to an increase in sagittal laxity, knee dysfunction, or accelerated damage to the tibial bearing surface. We conducted a prospective study on 74 consecutive mobile-bearing CR TKA to determine if knee laxity changed with time or if knees with large initial laxity experienced greater increases in laxity. Patients were studied with radiographic posterior and anterior drawer examinations at 3 and 23 months. Model-based shape-matching techniques were used to measure TKA kinematics. We found a 1-mm increase in posterior drawer. Knees with large postoperative drawers did not exhibit increased laxity at last follow-up. The use of a mobile-bearing CR TKA did not significantly modify the midterm knee sagittal laxity.


Subject(s)
Arthroplasty, Replacement, Knee , Joint Instability/physiopathology , Joint Instability/surgery , Knee Joint/surgery , Posterior Cruciate Ligament/physiopathology , Aged , Aged, 80 and over , Biomechanical Phenomena , Humans , Knee Joint/physiopathology , Knee Prosthesis , Middle Aged , Posterior Cruciate Ligament/surgery , Range of Motion, Articular
SELECTION OF CITATIONS
SEARCH DETAIL
...