Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 14(3): e0213339, 2019.
Article in English | MEDLINE | ID: mdl-30835766

ABSTRACT

PURPOSE: To compare the diagnostic performance and raters´confidence of radiography, radiography equivalent dose multi-detector computed tomography (RED-MDCT) and radiography equivalent dose cone beam computed tomography (RED-CBCT) for finger fractures. METHODS: Fractures were inflicted artificially and randomly to 10 cadaveric hands of body donors. Radiography as well as RED-MDCT and RED-CBCT imaging were performed at dose settings equivalent to radiography. Images were de-identified and analyzed by three radiologists regarding finger fractures, joint involvement and confidence with their findings. Reference standard was consensus reading by two radiologists of the fracturing protocol and high-dose multi-detector computed tomography (MDCT) images. Sensitivity and specificity were calculated and compared with Cochrane´s Q and post hoc analysis. Rater´s confidence was calculated with Friedman Test and post hoc Nemenyi Test. RESULTS: Rater´s confidence, inter-rater correlation, specificity for fractures and joint involvement were higher in RED-MDCT and RED-CBCT compared to radiography. No differences between the modalities were found regarding sensitivity. CONCLUSION: In this phantom study, radiography equivalent dose computed tomography (RED-CT) demonstrates a partly higher diagnostic accuracy than radiography. Implementing RED-CT in the diagnostic work-up of finger fractures could improve diagnostics, support correct classification and adequate treatment. Clinical studies should be performed to confirm these preliminary results.


Subject(s)
Cone-Beam Computed Tomography/methods , Finger Injuries/diagnosis , Fractures, Bone/diagnosis , Multidetector Computed Tomography/methods , Phantoms, Imaging , Radiography/methods , Finger Injuries/diagnostic imaging , Fractures, Bone/diagnostic imaging , Humans , Radiation Dosage
2.
Interact Cardiovasc Thorac Surg ; 24(5): 655-658, 2017 05 01.
Article in English | MEDLINE | ID: mdl-28453796

ABSTRACT

OBJECTIVES: Our goal was to describe a new standardized approach in patients with extensive obliterative arteriopathy aimed at distal revascularization and surgical kidney recruitment via descendo-bifemoral bypass grafting and renal artery revascularization. METHODS: Three patients with Leriche's syndrome and either a compromised single kidney or unilateral significant renal artery stenosis were treated with a standardized surgical approach, restoration of distal perfusion via descendo-bifemoral bypass with synchronous ( n = 2) left-sided renal artery revascularization or metachronous ( n = 1) right-sided renal artery revascularization. RESULTS: The intended surgical aim was achieved successfully in all 3 cases. All patients showed a decline in serum creatinine levels. One patient who needed substitution therapy was free from dialysis 3 months after surgery. Additionally, blood pressure management was substantially reduced because uncontrolled peak systolic episodes were no longer observed and pharmacotherapeutic agents could be partially withdrawn. CONCLUSIONS: Distal revascularization and surgical kidney recruitment via descendo-bifemoral bypass and renal artery revascularization is a promising option to treat complex obliterative arteriopathy.


Subject(s)
Aorta, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Femoral Artery/surgery , Kidney/blood supply , Leriche Syndrome/surgery , Renal Artery Obstruction/surgery , Renal Artery/surgery , Anastomosis, Surgical/methods , Computed Tomography Angiography , Female , Humans , Leriche Syndrome/complications , Leriche Syndrome/diagnosis , Male , Middle Aged , Renal Artery Obstruction/diagnosis , Treatment Outcome
3.
Neuroradiology ; 54(3): 215-23, 2012 Mar.
Article in English | MEDLINE | ID: mdl-21476020

ABSTRACT

INTRODUCTION: The aim of this study is to report our early clinical experience using C-arm cone beam computed tomography with fluoroscopic overlay for image guidance during percutaneous needle procedures of the spine and pelvis. METHODS: Twelve consecutive patients (four female and eight male patients; mean age, 64 years; range, 47-74 years; SD ± 7.6 years) who underwent percutaneous biopsy of the spine and pelvis for suspected metastasis (n = 12), spondylodiscitis (n = 6), abscess (n = 5) or bone tumour (n = 1) were prospectively included between March 2009 and November 2010. The procedures were performed on the Allura Xper FD20/20 (Philips, Best, the Netherlands) using cone beam computed tomography (XperCT) with the C-arm combined with fluoroscopic overlay for needle guidance. Based on an initial XperCT, entry and target points were defined using dedicated guidance software (XperGuide). The needle path was visualised in various reconstructed planes and could be adjusted when considered necessary. For percutaneous interventions, the entry view (overlay of entry and target point in the bull's eye fashion), the progression view (perpendicular to the entry view) as well as two additional views could automatically be piloted to with the C-arm system. Needle navigation was supported by a biopsy guidance device (Seestar, Radi, Uppsala, Sweden). Correct needle positioning was confirmed with a second XperCT acquisition. Technical success was defined as any target point reached via the planned needle trajectory with a distance of final needle tip within 5 mm of the planned target point in any direction. RESULTS: In all 12 patients, target areas could be defined based on XperCT data. In 11 of 12 (92%) cases, the target point was successfully reached on the planned trajectory with a mean error of 2.8 mm (range, 0.5-9.4 mm; SD, 2.4 mm). No peri- or post-interventional complications occurred. CONCLUSION: XperCT-guided interventions with the XperGuide system seem a safe and reliable tool for percutaneous needle interventions of the spine and pelvis. The advantage of the technique when compared to CT- or fluoroscopy-guided interventions needs to be determined in a comparative study of a larger scale.


Subject(s)
Abscess/pathology , Biopsy, Needle/methods , Bone Neoplasms/pathology , Cone-Beam Computed Tomography/methods , Discitis/pathology , Radiography, Abdominal/methods , Radiography, Interventional/methods , Abscess/diagnostic imaging , Aged , Bone Neoplasms/diagnostic imaging , Contrast Media , Discitis/diagnostic imaging , Female , Fluoroscopy , Humans , Male , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted
5.
Invest Radiol ; 43(10): 703-11, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18791412

ABSTRACT

OBJECTIVE: To compare the image quality of mono- versus bisegment reconstruction algorithms for dual-source computed tomography coronary angiography (CTCA). MATERIALS AND METHODS: Eighty consecutive patients (27 women; average age, 60 +/- 12 years) were randomly assigned to 2 different CTCA scanning protocols: 40 patients (group A) underwent dual-source CTCA with a heart rate (HR)-dependent pitch adaptation with datasets reconstructed using the monosegment algorithm; 40 patients (group B) underwent CTCA at a fixed pitch of 0.2 and datasets were reconstructed using both mono- and bisegment algorithms. The temporal resolution was 82 milliseconds for mono- and 42 to 83 milliseconds (58 +/- 14 milliseconds) for bisegment reconstruction, the latter depending on the HR during CTCA. Images were reconstructed in the reconstruction phase having least motion artifacts in the individual patient, primarily during mid-diastole at 70% of the R-R interval. The HR variability was defined as the standard deviation from the average HR. Two blinded observers independently assessed the image quality of each coronary segment using a 4-point scale (1: excellent to 4: nonevaluable). Effective radiation dose estimates were calculated. RESULTS: The overall image quality showed no significant differences between the 2 groups scanned with a fixed or a HR-adapted pitch (group A, score 1.21 +/- 0.63; group B, score 1.19 +/- 0.52). The overall image quality was superior when using monosegment (group A and B, score 1.21 +/- 0.63 and 1.19 +/- 0.52, respectively) when compared with the bisegment reconstruction algorithm (group B, score 1.33 +/- 0.72; P < 0.01). Image quality did not significantly correlate with average HR neither for monosegment (group A: r = 0.07; P = 0.35; group B: r = 0.06; P = 0.41) nor bisegment reconstructions (r = 0.07; P = 0.32). There was no significant correlation between image quality and HR variability using monosegment reconstructions (group A: r = 0.09; P = 0.22; group B: r = 0.05; P = 0.67), whereas a significant correlation was found for bisegment reconstructions (group B: r = 0.51; P < 0.01). The estimated effective radiation dose was significantly higher in group B (10.8 +/- 1.4 mSv) when compared with group A (9.0 +/- 0.8 mSv; P < 0.01). CONCLUSIONS: Although providing a higher temporal resolution at certain HRs, the use of bisegment reconstructions for dual-source CTCA does not result in an improved overall image quality when compared with the monosegment reconstruction algorithm.


Subject(s)
Algorithms , Coronary Angiography/instrumentation , Coronary Vessels/physiology , Image Processing, Computer-Assisted/instrumentation , Radiation Dosage , Tomography, X-Ray Computed/instrumentation , Adult , Aged , Aged, 80 and over , Coronary Vessels/pathology , Female , Humans , Image Enhancement/instrumentation , Linear Models , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...