1.
Resusc Plus ; 19: 100663, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38827273

ABSTRACT

Background: There is a lack of bench systems permitting to evaluate ventilation devices in the specific context of cardiac arrest. Objectives: The objective of the study is to assess if a new physiological manikin may permit to evaluate the performances of medical devices dedicated to ventilation during cardiopulmonary resuscitation (CPR). Methods: Specific CPR-related features required to reproduce realistic ventilation were implemented into the SAM (Sarthe Anjou Mayenne) manikin. In the first place, the manikin ability to mimic ventilation during CPR was assessed and compared to real-life tracings of airway pressure, flow and capnogram from three out of hospital cardiac arrest (OHCA) patients. In addition, to illustrate the interest of this manikin, ventilation was evaluated during mechanical continuous chest compressions with two devices dedicated to CPR: the Boussignac cardiac arrest device (B-card - Vygon; Ecouen France) and the Impedance Threshold Device (ITD - Zoll; Chelmsford, MA). Results: The SAM manikin enabled precise replication of ventilation tracings as observed in three OHCA patients during CPR, and it allowed for comparison between two distinct ventilation devices. B-card generated a mean, maximum and minimum intrathoracic pressure of 6.3 (±0.1) cmH2O, 18.9 (±1.1) cmH2O and -0.3 (±0.2) cmH2O respectively; while ITD generated a mean, maximum and minimum intrathoracic pressure of -1.6 (±0.0) cmH2O, 5.7 (±0.1) cmH2O and -4.8 (±0.1) cmH2O respectively during CPR. B-card allowed to increase passive ventilation compared to the ITD which resulted in a dramatic limitation of passive ventilation. Conclusion: The SAM manikin is an innovative model integrating specific physiological features that permit to accurately evaluate and compare ventilation devices during CPR.

2.
Ann Intensive Care ; 14(1): 1, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38180544

ABSTRACT

BACKGROUND: Various Positive End-Expiratory Pressure (PEEP) titration strategies have been proposed to optimize ventilation in patients with acute respiratory distress syndrome (ARDS). We aimed to compare PEEP titration strategies based on electrical impedance tomography (EIT) to methods derived from respiratory system mechanics with or without esophageal pressure measurements, in terms of PEEP levels and association with recruitability. METHODS: Nineteen patients with ARDS were enrolled. Recruitability was assessed by the estimated Recruitment-to-Inflation ratio (R/Iest) between PEEP 15 and 5 cmH2O. Then, a decremental PEEP trial from PEEP 20 to 5 cmH2O was performed. PEEP levels determined by the following strategies were studied: (1) plateau pressure 28-30 cmH2O (Express), (2) minimal positive expiratory transpulmonary pressure (Positive PLe), (3) center of ventilation closest to 0.5 (CoV) and (4) intersection of the EIT-based overdistension and lung collapse curves (Crossing Point). In addition, the PEEP levels determined by the Crossing Point strategy were assessed using different PEEP ranges during the decremental PEEP trial. RESULTS: Express and CoV strategies led to higher PEEP levels than the Positive PLe and Crossing Point ones (17 [14-17], 20 [17-20], 8 [5-11], 10 [8-11] respectively, p < 0.001). For each strategy, there was no significant association between the optimal PEEP level and R/Iest (Crossing Point: r2 = 0.073, p = 0.263; CoV: r2 < 0.001, p = 0.941; Express: r2 < 0.001, p = 0.920; Positive PLe: r2 = 0.037, p = 0.461). The PEEP level obtained with the Crossing Point strategy was impacted by the PEEP range used during the decremental PEEP trial. CONCLUSIONS: CoV and Express strategies led to higher PEEP levels than the Crossing Point and Positive PLe strategies. Optimal PEEP levels proposed by these four methods were not associated with recruitability. Recruitability should be specifically assessed in ARDS patients to optimize PEEP titration.

3.
Crit Care ; 27(1): 343, 2023 09 04.
Article in English | MEDLINE | ID: mdl-37667379

ABSTRACT

BACKGROUND: Respiratory mechanics is a key element to monitor mechanically ventilated patients and guide ventilator settings. Besides the usual basic assessments, some more complex explorations may allow to better characterize patients' respiratory mechanics and individualize ventilation strategies. These advanced respiratory mechanics assessments including esophageal pressure measurements and complete airway closure detection may be particularly relevant in critically ill obese patients. This study aimed to comprehensively assess respiratory mechanics in obese and non-obese ICU patients with or without ARDS and evaluate the contribution of advanced respiratory mechanics assessments compared to basic assessments in these patients. METHODS: All intubated patients admitted in two ICUs for any cause were prospectively included. Gas exchange and respiratory mechanics including esophageal pressure and end-expiratory lung volume (EELV) measurements and low-flow insufflation to detect complete airway closure were assessed in standardized conditions (tidal volume of 6 mL kg-1 predicted body weight (PBW), positive end-expiratory pressure (PEEP) of 5 cmH2O) within 24 h after intubation. RESULTS: Among the 149 analyzed patients, 52 (34.9%) were obese and 90 (60.4%) had ARDS (65.4% and 57.8% of obese and non-obese patients, respectively, p = 0.385). A complete airway closure was found in 23.5% of the patients. It was more frequent in obese than in non-obese patients (40.4% vs 14.4%, p < 0.001) and in ARDS than in non-ARDS patients (30% vs. 13.6%, p = 0.029). Respiratory system and lung compliances and EELV/PBW were similarly decreased in obese patients without ARDS and obese or non-obese patients with ARDS. Chest wall compliance was not impacted by obesity or ARDS, but end-expiratory esophageal pressure was higher in obese than in non-obese patients. Chest wall contribution to respiratory system compliance differed widely between patients but was not predictable by their general characteristics. CONCLUSIONS: Most respiratory mechanics features are similar in obese non-ARDS and non-obese ARDS patients, but end-expiratory esophageal pressure is higher in obese patients. A complete airway closure can be found in around 25% of critically ill patients ventilated with a PEEP of 5 cmH2O. Advanced explorations may allow to better characterize individual respiratory mechanics and adjust ventilation strategies in some patients. Trial registration NCT03420417 ClinicalTrials.gov (February 5, 2018).


Subject(s)
Critical Illness , Respiratory Distress Syndrome , Humans , Body Weight , Obesity/complications , Respiration, Artificial , Respiratory Distress Syndrome/complications , Respiratory Distress Syndrome/therapy , Respiratory Mechanics
4.
Crit Care ; 27(1): 273, 2023 07 07.
Article in English | MEDLINE | ID: mdl-37420282

ABSTRACT

BACKGROUND: Airway opening pressure (AOP) detection and measurement are essential for assessing respiratory mechanics and adapting ventilation. We propose a novel approach for AOP assessment during volume assist control ventilation at a usual constant-flow rate of 60 L/min. OBJECTIVES: To validate the conductive pressure (Pcond) method, which compare the Pcond-defined on the airway pressure waveform as the difference between the airway pressure level at which an abrupt change in slope occurs at the beginning of insufflation and PEEP-to resistive pressure for AOP detection and measurement, and to compare its respiratory and hemodynamic tolerance to the standard low-flow insufflation method. METHODS: The proof-of-concept of the Pcond method was assessed on mechanical (lung simulator) and physiological (cadavers) bench models. Its diagnostic performance was evaluated in 213 patients, using the standard low-flow insufflation method as a reference. In 45 patients, the respiratory and hemodynamic tolerance of the Pcond method was compared with the standard low-flow method. MEASUREMENTS AND MAIN RESULTS: Bench assessments validated the Pcond method proof-of-concept. Sensitivity and specificity of the Pcond method for AOP detection were 93% and 91%, respectively. AOP obtained by Pcond and standard low-flow methods strongly correlated (r = 0.84, p < 0.001). Changes in SpO2 were significantly lower during Pcond than during standard method (p < 0.001). CONCLUSION: Determination of Pcond during constant-flow assist control ventilation may permit to easily and safely detect and measure AOP.


Subject(s)
Insufflation , Humans , Insufflation/methods , Lung , Respiratory Physiological Phenomena , Respiratory Mechanics , Respiration, Artificial/methods
5.
Crit Care ; 27(1): 262, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37403149

ABSTRACT

BACKGROUND: Several noninvasive ventilatory supports rely in their design on high oxygen consumption which may precipitate oxygen shortage, as experienced during the COVID-19 pandemic. In this bench-to-bedside study, we assessed the performance of a new continuous positive airway pressure (CPAP) device integrating a large reservoir ("Bag-CPAP") designed to minimize oxygen consumption, and compared it with other CPAP devices. METHODS: First, a bench study compared the performances of Bag-CPAP and four CPAP devices with an intensive care unit ventilator. Two FiO2 targets (40-60% and 80-100%) at a predefined positive end expiratory pressure (PEEP) level between 5 and 10 cm H2O were tested and fraction of inspired oxygen (FiO2) and oxygen consumption were measured. Device-imposed work of breathing (WOB) was also evaluated. Second, an observational clinical study evaluated the new CPAP in 20 adult patients with acute respiratory failure in two hospitals in France. Actual FiO2, PEEP, peripheral oxygen saturation, respiratory rate, and dyspnea score were assessed. RESULTS: All six systems tested in the bench study reached the minimal FiO2 target of 40% and four reached at least 80% FiO2 while maintaining PEEP in the predefined range. Device-delivered FiO2/consumed oxygen ratio was the highest with the new reservoir-based CPAP irrespective of FiO2 target. WOB induced by the device was higher with Bag-CPAP. In the clinical study, Bag-CPAP was well tolerated and could reach high (> 90%) and moderate (> 50%) FiO2 with an oxygen flow rate of 15 [15-16] and 8 [7-9] L/min, respectively. Dyspnea score improved significantly after introduction of Bag-CPAP, and SpO2 increased. CONCLUSIONS: In vitro, Bag-CPAP exhibited the highest oxygen saving properties albeit had increased WOB. It was well accepted clinically and reduced dyspnea. Bag-CPAP may be useful to treat patients with acute respiratory failure in the field, especially when facing constraints in oxygen delivery.


Subject(s)
COVID-19 , Respiratory Insufficiency , Adult , Humans , Continuous Positive Airway Pressure , COVID-19/therapy , Dyspnea , Oxygen , Oxygen Consumption , Pandemics , Respiratory Insufficiency/therapy
6.
Crit Care ; 26(1): 287, 2022 09 23.
Article in English | MEDLINE | ID: mdl-36151559

ABSTRACT

BACKGROUND: Cardiopulmonary resuscitation (CPR) decreases lung volume below the functional residual capacity and can generate intrathoracic airway closure. Conversely, large insufflations can induce thoracic distension and jeopardize circulation. The capnogram (CO2 signal) obtained during continuous chest compressions can reflect intrathoracic airway closure, and we hypothesized here that it can also indicate thoracic distension. OBJECTIVES: To test whether a specific capnogram may identify thoracic distension during CPR and to assess the impact of thoracic distension on gas exchange and hemodynamics. METHODS: (1) In out-of-hospital cardiac arrest patients, we identified on capnograms three patterns: intrathoracic airway closure, thoracic distension or regular pattern. An algorithm was designed to identify them automatically. (2) To link CO2 patterns with ventilation, we conducted three experiments: (i) reproducing the CO2 patterns in human cadavers, (ii) assessing the influence of tidal volume and respiratory mechanics on thoracic distension using a mechanical lung model and (iii) exploring the impact of thoracic distension patterns on different circulation parameters during CPR on a pig model. MEASUREMENTS AND MAIN RESULTS: (1) Clinical data: 202 capnograms were collected. Intrathoracic airway closure was present in 35%, thoracic distension in 22% and regular pattern in 43%. (2) Experiments: (i) Higher insufflated volumes reproduced thoracic distension CO2 patterns in 5 cadavers. (ii) In the mechanical lung model, thoracic distension patterns were associated with higher volumes and longer time constants. (iii) In six pigs during CPR with various tidal volumes, a CO2 pattern of thoracic distension, but not tidal volume per se, was associated with a significant decrease in blood pressure and cerebral perfusion. CONCLUSIONS: During CPR, capnograms reflecting intrathoracic airway closure, thoracic distension or regular pattern can be identified. In the animal experiment, a thoracic distension pattern on the capnogram is associated with a negative impact of ventilation on blood pressure and cerebral perfusion during CPR, not predicted by tidal volume per se.


Subject(s)
Cardiopulmonary Resuscitation , Out-of-Hospital Cardiac Arrest , Animals , Cadaver , Carbon Dioxide , Humans , Lung , Swine
8.
Ann Intensive Care ; 11(1): 38, 2021 Mar 02.
Article in English | MEDLINE | ID: mdl-33655452

ABSTRACT

BACKGROUND: We describe a frugal approach (focusing on needs, performance, and costs) to manage a massive influx of COVID-19 patients with acute hypoxemic respiratory failure (AHRF) using the Boussignac valve protected by a filter ("Filter Frugal CPAP", FF-CPAP) in and out the ICU. METHODS: (1) A bench study measured the impact of two filters with different mechanical properties on CPAP performances, and pressures were also measured in patients. (2) Non-ICU healthcare staff working in COVID-19 intermediate care units were trained with a video tutorial posted on a massive open online course. (3) A clinical study assessed the feasibility and safety of using FF-CPAP to maintain oxygenation and manage patients out of the ICU during a massive outbreak. RESULTS: Bench assessments showed that adding a filter did not affect the effective pressure delivered to the patient. The resistive load induced by the filter variably increased the simulated patient's work of breathing (6-34%) needed to sustain the tidal volume, depending on the filter's resistance, respiratory mechanics and basal inspiratory effort. In patients, FF-CPAP achieved pressures similar to those obtained on the bench. The massive training tool provided precious information on the use of Boussignac FF-CPAP on COVID-19 patients. Then 85 COVID-19 patients with ICU admission criteria over a 1-month period were studied upon FF-CPAP initiation for AHRF. FF-CPAP significantly decreased respiratory rate and increased SpO2. Thirty-six (43%) patients presented with respiratory indications for intubation prior to FF-CPAP initiation, and 13 (36%) of them improved without intubation. Overall, 31 patients (36%) improved with FF-CPAP alone and 17 patients (20%) did not require ICU admission. Patients with a respiratory rate > 32 breaths/min upon FF-CPAP initiation had a higher cumulative probability of intubation (p < 0.001 by log-rank test). CONCLUSION: Adding a filter to the Boussignac valve does not affect the delivered pressure but may variably increase the resistive load depending on the filter used. Clinical assessment suggests that FF-CPAP is a frugal solution to provide a ventilatory support and improve oxygenation to numerous patients suffering from AHRF in the context of a massive outbreak.

9.
Ann Intensive Care ; 10(1): 166, 2020 Dec 09.
Article in English | MEDLINE | ID: mdl-33296045

ABSTRACT

BACKGROUND: Intensive Care Units (ICU) have sometimes been overwhelmed by the surge of COVID-19 patients. Extending ICU capacity can be limited by the lack of air and oxygen pressure sources available. Transport ventilators requiring only one O2 source may be used in such places. OBJECTIVE: To evaluate the performances of four transport ventilators and an ICU ventilator in simulated severe respiratory conditions. MATERIALS AND METHODS: Two pneumatic transport ventilators, (Oxylog 3000, Draeger; Osiris 3, Air Liquide Medical Systems), two turbine transport ventilators (Elisee 350, ResMed; Monnal T60, Air Liquide Medical Systems) and an ICU ventilator (Engström Carestation-GE Healthcare) were evaluated on a Michigan test lung. We tested each ventilator with different set volumes (Vtset = 350, 450, 550 ml) and compliances (20 or 50 ml/cmH2O) and a resistance of 15 cmH2O/l/s based on values described in COVID-19 Acute Respiratory Distress Syndrome. Volume error (percentage of Vtset) with P0.1 of 4 cmH2O and trigger delay during assist-control ventilation simulating spontaneous breathing activity with P0.1 of 4 cmH2O and 8 cmH2O were measured. RESULTS: Grouping all conditions, the volume error was 2.9 ± 2.2% for Engström Carestation; 3.6 ± 3.9% for Osiris 3; 2.5 ± 2.1% for Oxylog 3000; 5.4 ± 2.7% for Monnal T60 and 8.8 ± 4.8% for Elisee 350. Grouping all conditions (P0.1 of 4 cmH2O and 8 cmH2O), trigger delay was 50 ± 11 ms, 71 ± 8 ms, 132 ± 22 ms, 60 ± 12 and 67 ± 6 ms for Engström Carestation, Osiris 3, Oxylog 3000, Monnal T60 and Elisee 350, respectively. CONCLUSIONS: In surge situations such as COVID-19 pandemic, transport ventilators may be used to accurately control delivered volumes in locations, where only oxygen pressure supply is available. Performances regarding triggering function are acceptable for three out of the four transport ventilators tested.

10.
JACC Cardiovasc Imaging ; 13(12): 2619-2631, 2020 12.
Article in English | MEDLINE | ID: mdl-32828786

ABSTRACT

OBJECTIVES: Among all patients presenting with myocardial infarction with nonobstructive coronary arteries (MINOCA), epicardial causes may be suspected when there is a correlation between electrocardiogram (ECG) changes and regional wall motion abnormalities (WMAs). We evaluated the diagnostic yield of intravascular optical coherence tomography (OCT) and cardiac magnetic resonance (CMR) in this specific setting. BACKGROUND: OCT is able to identify different morphologic features of coronary plaques that are well known causes of MINOCA. Furthermore, CMR has become the gold standard for detection of myocardial infarction in the setting of MINOCA. METHODS: In a prospective 2-center study, consecutive patients with MINOCA including ECG features of ischemia associated with corresponding WMAs underwent OCT and CMR. RESULTS: Forty patients (mean age: 50 ± 11 years, 62.5% male, 32.5% with ST-segment elevation) were enrolled. Coronary arteries were normal on coronary angiography in 10 patients (25%); 18 patients (45%) presented minimal lumen irregularities, whereas the remaining 12 patients (30%) showed mild to moderate (≥30% but <50%) coronary lesions. Plaque rupture, eruptive calcific nodule, plaque erosion, lone thrombus, and spontaneous coronary artery dissection were found in 14 (35%), 1 (2.5%), 12 (30%), 3 (7.5%), and 2 (5%) patients, respectively. Acute myocardial infarction was evident at CMR in 31 of 40 patients (77.5%). Twenty-three patients (57.5%) had a substrate and/or diagnosis supported by both techniques with an evident relationship between the findings obtained by the 2 techniques. By coupling OCT with CMR, a substrate and/or diagnosis was found in 100% of cases. CONCLUSIONS: OCT coupled with CMR can provide a clear substrate and/or diagnosis in the vast majority of patients presenting with MINOCA including ECG features of ischemia associated with corresponding WMAs.


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Adult , Coronary Angiography , Coronary Vessels , Female , Humans , Magnetic Resonance Spectroscopy , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Tomography, Optical Coherence
11.
Resuscitation ; 146: 111-117, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31730897

ABSTRACT

INTRODUCTION: Bag-valve-mask ventilation is the first-line ventilation method during cardiopulmonary resuscitation (CPR). Risks include excessive volume delivery and gastric insufflation, the latter increasing the risk of pneumonia. The efficacy of ventilation can also be reduced by airway closure. We hypothesized that continuous chest compression (CC) could limit the risk of gastric insufflation compared to the recommended 30:2 interrupted CC strategy. This experimental study was performed in human "Thiel" cadavers to assess the respective impact of discontinuous vs. continuous chest compressions on gastric insufflation and ventilation during CPR. METHODS: The 30:2 interrupted CC technique was compared to continuous CC in 5 non-intubated cadavers over a 6 min-period. Flow and Airway Pressure were measured at the mask. A percutaneous gastrostomy allowed measuring the cumulative gastric insufflated volume. Two additional cadavers were equipped with esophageal and gastric catheters instead of the gastrostomy. RESULTS: For the 7 cadavers studied (4 women) median age of death was 79 [74-84] years. After 6 min of CPR, the cumulative gastric insufflation measured in 5 cadavers was markedly reduced during continuous CC compared to the interrupted CC strategy: (1.0 [0.8-4.1] vs. 5.9 [4.0-5.6] L; p < 0.05) while expired minute ventilation was slightly higher during continuous than interrupted CC (1.9 [1.4-2.8] vs. 1.6 [1.1-2.7] L/min; P < 0.05). In 2 additional cadavers, the progressive rise in baseline gastric pressure was lower during continuous CC than interrupted CC (1 and 2 cmH2O vs. 12 and 5.8 cmH2O). CONCLUSION: Continuous CC significantly reduces the volume of gas insufflated in the stomach compared to the recommended 30:2 interrupted CC strategy. Ventilation actually delivered to the lung is also slightly increased by the strategy.


Subject(s)
Cardiopulmonary Resuscitation/methods , Heart Arrest/therapy , Heart Massage/methods , Noninvasive Ventilation , Pulmonary Ventilation , Aged , Cadaver , Female , Gastric Dilatation/diagnosis , Gastric Dilatation/etiology , Gastric Dilatation/prevention & control , Humans , Male , Noninvasive Ventilation/adverse effects , Noninvasive Ventilation/methods , Research Design
SELECTION OF CITATIONS