1.
Phys Rev Lett
; 96(9): 096101, 2006 Mar 10.
Article
in English
| MEDLINE
| ID: mdl-16606280
ABSTRACT
Inelastic electron tunneling spectroscopy (IETS) performed with the scanning tunneling microscope (STM) has been deemed as the ultimate tool for identifying chemicals on the atomic scale. However, IETS-based chemical analysis is error-prone due to the numerous degrees of freedom of chemisorbed molecular systems. First-principles simulations of IETS are presented that, by quantitative comparison with the experimental spectra, permit one to determine the final products of an STM-induced reaction on chemisorbed benzene. Our simulations reveal that IETS possesses an enhanced sensitivity to atomic structure as compared to topographic imaging due to both its energy and space resolution.