Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 30(Pt 4): 695-707, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37163303

ABSTRACT

In August 2021, the SOLEIL storage ring was restarted after the summer shutdown with a new bending magnet made entirely of permanent magnets. Producing a magnetic field of 2.8 T, it replaced one of the 32 electromagnetic dipoles (magnetic field of 1.7 T) of the ring to allow the ROCK beamline to exploit more intense photon fluxes in the hard X-ray range, thus improving the time resolution performances of the beamline for experiments carried out above 20 keV. The reduction of the new dipole magnetic gap required to produce the higher field has led to the construction and installation of a new vacuum vessel. The realization of the new dipole with permanent magnets was a technological feat due to the very strong magnetic forces. The permanent-magnet assembly required dedicated tools to be designed and constructed. Thanks to accurate magnetic measurements, a precise modelization of the new dipole was performed to identify its effects on the electron beam dynamics. The first measurements carried out on the ROCK beamline have highlighted the expected increase in photon flux, and the operation performances remain unchanged for the other beamlines. Here, the major developments and results of this innovative project are described in terms of technology, electron beam dynamics and photon beam performance on the ROCK beamline.


Subject(s)
Magnets , Synchrotrons , X-Rays , Photons
2.
Rev Sci Instrum ; 88(5): 053703, 2017 May.
Article in English | MEDLINE | ID: mdl-28571450

ABSTRACT

The field of three-dimensional multi-modal X-ray nanoimaging relies not only on high-brilliance X-rays but also on high-precision mechanics and position metrology. Currently available state-of-the-art linear and rotary drives can provide 3D position accuracy within tens to hundreds of nm, which is often insufficient for high resolution imaging with nanofocused X-ray beams. Motion errors are especially troublesome in the case of rotation drives and their correction is more complicated and relies on the metrology grade reference objects. Here we present a method which allows the characterisation and correction of the radial and angular errors of the rotary drives without the need for a highly accurate metrology object. The method is based on multi-probe error separation using fiber-laser interferometry and uses a standard cylindrical sample holder as a reference. The obtained runout and shape measurements are then used to perform the position corrections using additional drives. We demonstrate the results of the characterization for a piezo-driven small rotation stage. The error separation allowed us to measure the axis runout to be approximately ±1.25 µm, and with active runout compensation this could be reduced down to ±42 nm.

3.
J Synchrotron Radiat ; 18(Pt 4): 546-9, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21685669

ABSTRACT

In order to deliver VUV (vacuum ultraviolet) photons under atmospheric pressure conditions, a differential pumping system has been built on the DISCO beamline at the SOLEIL synchrotron radiation facility. The system is made of four stages and is 840 mm long. The conductance-limiting body has been designed to allow practicable optical alignment. VUV transmission of the system was tested under air, nitrogen, argon and neon, and photons could be delivered down to 60 nm (20 eV).

SELECTION OF CITATIONS
SEARCH DETAIL
...