Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Med Mycol ; 2022 Jun 14.
Article in English | MEDLINE | ID: mdl-35700147

ABSTRACT

We compared PneumID PCR with Amplex eazyplex LAMP assay for the diagnosis of Pneumocystis jirovecii pneumonia (PJP). Both assays enable accurate diagnosis of definite PJP. Cut-off cycle threshold of the PneumID assay was < 26.68 while the cut-off time-to-positivity of the eazyplex assay was 16:02 (minutes:seconds). The positive and negative percentage agreement of eazyplex assay with PneumID assay was 75.0% and 100.0% respectively, while the overall agreement was substantial with kappa = 0.80. For both assays, establishment of cut-off values to differentiate probable PJP from colonization was not feasible as results overlapped.


Both PneumID PCR and Amplex eazyplex LAMP assay enable accurate diagnosis of definite Pneumocystis jirovecii pneumonia (PJP). PneumID assay was more sensitive than eazyplex assay for detection of P. jirovecii. However, differentiation between probable PJP from colonization was not feasible.

3.
J Med Virol ; 93(3): 1824-1827, 2021 03.
Article in English | MEDLINE | ID: mdl-33165945

ABSTRACT

We describe the timely adaption of both published WHO E-gene protocol and commercially available LightMix Modular E-gene assay to the test platform (ABI 7900 Fast real-time analyzer and TaqMan Fast One-step Virus Master Mix) available in an accredited tertiary hospital laboratory with an on-going evaluation to ensure the provision of quality service within the time constraint. The LightMix Modular E-gene was slightly more sensitive when compared to the WHO E-gene, both analytically and diagnostically. The assay was recommended for screening of SARS-CoV-2 infection. With the availability of technically competent staff through continuous training, the provision of round-the-clock service is feasible despite the test is of high complexity. The thermal cycling duration of the adapted LightMix E-gene and WHO E-gene is shortened by half and one hour respectively and allows the number of runs to double when 24-h round-the-clock service is provided. An increase in testing capacity could support surges in testing demand, which is essential to control the current SARS-CoV-2 pandemic, to prevent potential overwhelming of the healthcare system, and to optimize utilization of the isolation beds.


Subject(s)
COVID-19/diagnosis , COVID-19/virology , Coronavirus Envelope Proteins/genetics , Genes, env/genetics , SARS-CoV-2/genetics , COVID-19 Testing/methods , Clinical Laboratory Techniques/methods , Hospitals , Humans , Pandemics/prevention & control , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction/methods , Reverse Transcriptase Polymerase Chain Reaction/methods , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...