Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Front Digit Health ; 5: 1258915, 2023.
Article in English | MEDLINE | ID: mdl-38111608

ABSTRACT

Introduction: Respiratory diseases such as chronic obstructive pulmonary disease, obstructive sleep apnea syndrome, and COVID-19 may cause a decrease in arterial oxygen saturation (SaO2). The continuous monitoring of oxygen levels may be beneficial for the early detection of hypoxemia and timely intervention. Wearable non-invasive pulse oximetry devices measuring peripheral oxygen saturation (SpO2) have been garnering increasing popularity. However, there is still a strong need for extended and robust clinical validation of such devices, especially to address topical concerns about disparities in performances across racial groups. This prospective clinical validation aimed to assess the accuracy of the reflective pulse oximeter function of the EmbracePlus wristband during a controlled hypoxia study in accordance with the ISO 80601-2-61:2017 standard and the Food & Drug Administration (FDA) guidance. Methods: Healthy adult participants were recruited in a controlled desaturation protocol to reproduce mild, moderate, and severe hypoxic conditions with SaO2 ranging from 100% to 70% (ClinicalTrials.gov registration #NCT04964609). The SpO2 level was estimated with an EmbracePlus device placed on the participant's wrist and the reference SaO2 was obtained from blood samples analyzed with a multiwavelength co-oximeter. Results: The controlled hypoxia study yielded 373 conclusive measurements on 15 subjects, including 30% of participants with dark skin pigmentation (V-VI on the Fitzpatrick scale). The accuracy root mean square (Arms) error was found to be 2.4%, within the 3.5% limit recommended by the FDA. A strong positive correlation between the wristband SpO2 and the reference SaO2 was observed (r = 0.96, P < 0.001), and a good concordance was found with Bland-Altman analysis (bias, 0.05%; standard deviation, 1.66; lower limit, -4.7%; and upper limit, 4.8%). Moreover, acceptable accuracy was observed when stratifying data points by skin pigmentation (Arms 2.2% in Fitzpatrick V-VI, 2.5% in Fitzpatrick I-IV), and sex (Arms 1.9% in females, and 2.9% in males). Discussion: This study demonstrates that the EmbracePlus wristband could be used to assess SpO2 with clinically acceptable accuracy under no-motion and high perfusion conditions for individuals of different ethnicities across the claimed range. This study paves the way for further accuracy evaluations on unhealthy subjects and during prolonged use in ambulatory settings.

2.
JMIR Form Res ; 6(7): e37832, 2022 Jul 29.
Article in English | MEDLINE | ID: mdl-35852933

ABSTRACT

BACKGROUND: The SARS-CoV-2 (COVID-19) pandemic may accelerate the adoption of digital, decentralized clinical trials. Conceptual recommendations for digitalized and remote clinical studies and technology are available to enable digitalization. Fully remote studies may break down some of the participation barriers in traditional trials. However, they add logistical complexity and offer fewer opportunities to intervene following a technical failure or adverse event. OBJECTIVE: Our group designed an end-to-end digitalized clinical study protocol, using the Food and Drug Administration (FDA)-cleared Current Health (CH) remote monitoring platform to collect symptoms and continuous physiological data of individuals recently infected with COVID-19 in the community. The purpose of this work is to provide a detailed example of an end-to-end digitalized protocol implementation based on conceptual recommendations by describing the study setup in detail, evaluating its performance, and identifying points of success and failure. METHODS: Primary recruitment was via social media and word of mouth. Informed consent was obtained during a virtual appointment, and the CH-monitoring kit was shipped directly to the participants. The wearable continuously recorded pulse rate (PR), respiratory rate (RR), oxygen saturation (SpO2), skin temperature, and step count, while a tablet administered symptom surveys. Data were transmitted in real time to the CH cloud-based platform and displayed in the web-based dashboard, with alerts to the study team if the wearable was not charged or worn. The study duration was up to 30 days. The time to recruit, screen, consent, set up equipment, and collect data was quantified, and advertising engagement was tracked with a web analytics service. RESULTS: Of 13 different study advertisements, 5 (38.5%) were live on social media at any one time. In total, 38 eligibility forms were completed, and 19 (50%) respondents met the eligibility criteria. Of these, 9 (47.4%) were contactable and 8 (88.9%) provided informed consent. Deployment times ranged from 22 to 110 hours, and participants set up the equipment and started transmitting vital signs within 7.6 (IQR 6.3-10) hours of delivery. The mean wearable adherence was 70% (SD 19%), and the mean daily survey adherence was 88% (SD 21%) for the 8 participants. Vital signs were in normal ranges during study participation, and symptoms decreased over time. CONCLUSIONS: Evaluation of clinical study implementation is important to capture what works and what might need to be modified. A well-calibrated approach to online advertising and enrollment can remove barriers to recruitment and lower costs but remains the most challenging part of research. Equipment was effectively and promptly shipped to participants and removed the risk of illness transmission associated with in-person encounters during a pandemic. Wearable technology incorporating continuous, clinical-grade monitoring offered an unprecedented level of detail and ecological validity. However, study planning, relationship building, and troubleshooting are more complex in the remote setting. The relevance of a study to potential participants remains key to its success.

3.
JMIR Form Res ; 6(7): e37567, 2022 Jul 05.
Article in English | MEDLINE | ID: mdl-35671408

ABSTRACT

BACKGROUND: During the COVID-19 pandemic, individuals with a positive viral test were enrolled in a study, within 48 hours, to remotely monitor their vital signs to characterize disease progression and recovery. A virtual trial design was adopted to reduce risks to participants and the research community in a study titled Risk Stratification and Early Alerting Regarding COVID-19 Hospitalization (RiskSEARCH). The Food and Drug Administration-cleared Current Health platform with a wearable device is a continuous remote patient monitoring technology that supports hospital-at-home care and is used as a data collection tool. Enrolled participants wore the Current Health wearable device continuously for up to 30 days and took a daily symptom survey via a tablet that was provided. A qualitative substudy was conducted in parallel to better understand virtual trial implementation, including barriers and facilitators for participants. OBJECTIVE: This study aimed to understand the barriers and facilitators of the user experience of interacting with a virtual care platform and research team, while participating in a fully virtual study using qualitative and quantitative data. METHODS: Semistructured interviews were conducted to understand participants' experience of participating in a virtual study during a global pandemic. The schedule included their experience of enrollment and their interactions with equipment and study staff. A total of 3 RiskSEARCH participants were interviewed over telephone, and transcriptions were inductively coded and analyzed using thematic analysis. Themes were mapped onto the Theoretical Domains Framework (TDF) to identify and describe the factors that influenced study adherence. Quantitative metrics, including adherence to wearable and scheduled tasks collected as part of the RiskSEARCH main study, were paired with the interviews to present an overall picture of participation. RESULTS: All participants exceeded our definition of a fully adherent participant and reported that participation was feasible and had a low burden. The symptoms progressively resolved during the trial. Inductive thematic analysis identified 13 main themes from the interview data, which were deductively mapped onto 11 of the 14 TDF domains, highlighting barriers and facilitators for each. CONCLUSIONS: Participants in the RiskSEARCH substudy showed high levels of adherence and engagement throughout participation. Although participants experienced some challenges in setting up and maintaining the Current Health kit (eg, charging devices), they reported feeling that the requirements of participation were both reasonable and realistic. We demonstrated that the TDF can be used for inductive thematic analysis. We anticipate expanding this work in future virtual studies and trials to identify barriers and enabling factors for implementation.

SELECTION OF CITATIONS
SEARCH DETAIL
...