Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
AJNR Am J Neuroradiol ; 43(11): 1615-1620, 2022 11.
Article in English | MEDLINE | ID: mdl-36229166

ABSTRACT

BACKGROUND AND PURPOSE: Flow diversion has gradually become a standard treatment for intracranial aneurysms of the anterior circulation. Recently, the off-label use of the flow diverters to treat posterior circulation aneurysms has also increased despite initial concerns of rupture and the suboptimal results. This study aimed to explore the change in complication rates and treatment outcomes across time for posterior circulation aneurysms treated using flow diversion and to further evaluate the mechanisms and variables that could potentially explain the change and outcomes. MATERIALS AND METHODS: A retrospective review using a standardized data set at multiple international academic institutions was performed to identify patients with ruptured and unruptured posterior circulation aneurysms treated with flow diversion during a decade spanning January 2011 to January 2020. This period was then categorized into 4 intervals. RESULTS: A total of 378 procedures were performed during the study period. Across time, there was an increasing tendency to treat more vertebral artery and fewer large vertebrobasilar aneurysms (P = .05). Moreover, interventionalists have been increasingly using fewer overlapping flow diverters per aneurysm (P = .07). There was a trend toward a decrease in the rate of thromboembolic complications from 15.8% in 2011-13 to 8.9% in 2018-19 (P = .34). CONCLUSIONS: This multicenter experience revealed a trend toward treating fewer basilar aneurysms, smaller aneurysms, and increased usage of a single flow diverter, leading to a decrease in the rate of thromboembolic and hemorrhagic complications.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Endovascular Procedures/methods , Learning Curve , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Cohort Studies , Retrospective Studies , Embolization, Therapeutic/methods , Stents
2.
AJNR Am J Neuroradiol ; 42(1): 57-64, 2021 01.
Article in English | MEDLINE | ID: mdl-33243895

ABSTRACT

BACKGROUND AND PURPOSE: Clot perviousness in acute ischemic stroke is a potential CT imaging biomarker for mechanical thrombectomy efficacy. We investigated the association among perviousness, clot cellular composition, and first-pass effect. MATERIALS AND METHODS: In 40 mechanical thrombectomy-treated cases of acute ischemic stroke, we calculated perviousness as the difference in clot density on CT angiography and noncontrast CT. We assessed the proportion of fibrin/platelet aggregates, red blood cells, and white blood cells on clot histopathology. We tested for linear correlation between histologic components and perviousness, differences in components between "high" and "low" pervious clots defined by median perviousness, and differences in perviousness/composition between cases that did and did not achieve a first-pass effect. RESULTS: Perviousness significantly positively and negatively correlated with the percentage of fibrin/platelet aggregates (P = .001) and the percentage of red blood cells (P = .001), respectively. Higher pervious clots had significantly greater fibrin/platelet aggregate content (P = .042). Cases that achieved a first-pass effect (n = 14) had lower perviousness, though not significantly (P = .055). The percentage of red blood cells was significantly higher (P = .028) and the percentage of fibrin/platelet aggregates was significantly lower (P = .016) in cases with a first-pass effect. There was no association between clot density on NCCT and clot composition or first-pass effect. Receiver operating characteristic analysis indicated that clot composition was the best predictor of first-pass effect (area under receiver operating characteristic curve: percentage of fibrin/platelet aggregates = 0.731, percentage of red blood cells = 0.706, perviousness = 0.668). CONCLUSIONS: Clot perviousness on CT is associated with a higher percentage of fibrin/platelet aggregate content. Histologic data and, to a lesser degree, perviousness may have value in predicting first-pass outcome. Imaging metrics that more strongly reflect clot biology than perviousness may be needed to predict a first-pass effect with high accuracy.


Subject(s)
Ischemic Stroke/diagnostic imaging , Ischemic Stroke/surgery , Thrombosis/diagnostic imaging , Treatment Outcome , Aged , Blood Platelets/pathology , Computed Tomography Angiography/methods , Female , Fibrin/analysis , Humans , Ischemic Stroke/pathology , Male , Thrombectomy/methods , Thrombosis/pathology
3.
AJNR Am J Neuroradiol ; 41(2): 206-212, 2020 02.
Article in English | MEDLINE | ID: mdl-31948951

ABSTRACT

BACKGROUND AND PURPOSE: Brain CTP is used to estimate infarct and penumbra volumes to determine endovascular treatment eligibility for patients with acute ischemic stroke. We aimed to assess the accuracy of a Bayesian CTP algorithm in determining penumbra and final infarct volumes. MATERIALS AND METHODS: Data were retrospectively collected for 105 patients with acute ischemic stroke (55 patients with successful recanalization [TICI 2b/2c/3] and large-vessel occlusions and 50 patients without interventions). Final infarct volumes were calculated using DWI and FLAIR 24 hours following CTP imaging. RAPID and the Vitrea Bayesian CTP algorithm (with 3 different settings) predicted infarct and penumbra volumes for comparison with final infarct volumes to assess software performance. Vitrea settings used different combinations of perfusion maps (MTT, TTP, CBV, CBF, delay time) for infarct and penumbra quantification. Patients with and without interventions were included for assessment of predicted infarct and penumbra volumes, respectively. RESULTS: RAPID and Vitrea default setting had the most accurate final infarct volume prediction in patients with interventions ([Spearman correlation coefficient, mean infarct difference] default versus FLAIR: [0.77, 4.1 mL], default versus DWI: [0.72, 4.7 mL], RAPID versus FLAIR: [0.75, 7.5 mL], RAPID versus DWI: [0.75, 6.9 mL]). Default Vitrea and RAPID were the most and least accurate in determining final infarct volume for patients without an intervention, respectively (default versus FLAIR: [0.76, -0.4 mL], default versus DWI: [0.71, -2.6 mL], RAPID versus FLAIR: [0.68, -49.3 mL], RAPID versus DWI: [0.65, -51.5 mL]). CONCLUSIONS: Compared with RAPID, the Vitrea default setting was noninferior for patients with interventions and superior in penumbra estimation for patients without interventions as indicated by mean infarct differences and correlations with final infarct volumes.


Subject(s)
Algorithms , Image Interpretation, Computer-Assisted/methods , Neuroimaging/methods , Perfusion Imaging/methods , Stroke/diagnostic imaging , Adult , Aged , Aged, 80 and over , Bayes Theorem , Brain Ischemia/diagnostic imaging , Brain Ischemia/pathology , Diffusion Magnetic Resonance Imaging/methods , Female , Humans , Male , Middle Aged , Retrospective Studies , Stroke/pathology , Tomography, X-Ray Computed/methods
4.
AJNR Am J Neuroradiol ; 40(7): 1197-1200, 2019 07.
Article in English | MEDLINE | ID: mdl-31171521

ABSTRACT

Traditional digital subtraction angiography provides rather limited evaluation of contrast flow dynamics when studying and treating intracranial brain aneurysms. A 1000-frames-per-second photon-counting x-ray detector was used to image detailed iodine-contrast flow patterns in an internal carotid artery aneurysm of a 3D-printed vascular phantom. High-speed imaging revealed differences in vortex and inflow patterns with and without a Pipeline Embolization Device flow diverter in more detail and clarity than could be seen in standard pulsed angiography. Improved temporal imaging has the potential to impact the outcomes of endovascular interventions by allowing clinicians to better understand and act on flow dynamics in real-time.


Subject(s)
Angiography, Digital Subtraction/methods , Cerebral Angiography/methods , Intracranial Aneurysm/diagnostic imaging , Models, Neurological , Neuroimaging/methods , Blood Vessel Prosthesis , Female , Humans , Male , Middle Aged , Phantoms, Imaging
5.
AJNR Am J Neuroradiol ; 40(2): 288-294, 2019 02.
Article in English | MEDLINE | ID: mdl-30679216

ABSTRACT

BACKGROUND AND PURPOSE: Incompletely occluded flow diverter treated aneurysms remain at risk of rupture and thromboembolic complications. Our aim was to identify the potential for incomplete occlusion of intracranial aneurysms treated by flow diverters. We investigated whether aneurysm ostium size in relation to parent artery size affects angiographic outcomes of flow diverter-treated sidewall aneurysms. MATERIALS AND METHODS: Flow diverter-treated sidewall aneurysms were divided into "occluded" and "residual" (incomplete occlusion) groups based on 6-month angiographic follow-up. We calculated the ostium ratio, a new parameter defined as the aneurysm ostium surface area versus the circumferential surface area of the parent artery. We also calculated the neck ratio, defined as clinical aneurysm neck diameter versus parent artery diameter from pretreatment 2D DSA, as a 2D surrogate. We compared the performance of these ratios with existing aneurysm morphometrics (size, neck diameter, volume, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, bottleneck factor, aneurysm angle, and parent vessel angle) and flow diverter-related parameters (metal coverage rate and pore density). Statistical tests and receiver operating characteristic analyses were performed to identify significantly different parameters between the 2 groups and test their predictive performances. RESULTS: We included 63 flow diverter-treated aneurysms, 46 occluded and 17 residual. The ostium ratio and neck ratio were significantly higher in the residual group than in the occluded group (P < .001 and P = .02, respectively), whereas all other parameters showed no statistical difference. As discriminating parameters for occlusion, ostium ratio and neck ratio achieved areas under the curve of 0.912 (95% CI, 0.838-0.985) and 0.707 (95% CI, 0.558-0.856), respectively. CONCLUSIONS: High ostium ratios and neck ratios could predict incomplete occlusion of flow diverter-treated sidewall aneurysms. Neck ratio can be easily calculated by interventionists to predict flow-diverter treatment outcomes.


Subject(s)
Intracranial Aneurysm/pathology , Intracranial Aneurysm/therapy , Stents , Treatment Outcome , Aged , Algorithms , Animals , Female , Humans , Male , Middle Aged
6.
AJNR Am J Neuroradiol ; 39(7): 1303-1309, 2018 07.
Article in English | MEDLINE | ID: mdl-29880475

ABSTRACT

BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device is increasingly used for endovascular treatment of intracranial aneurysms due to high reported obliteration rates and low associated morbidity. While obliteration of covered branches in the anterior circulation is generally asymptomatic, this has not been studied within the posterior circulation. The aim of this study was to evaluate the association between branch coverage and occlusion, as well as associated ischemic events in a cohort of patients with posterior circulation aneurysms treated with the Pipeline Embolization Device. MATERIALS AND METHODS: A retrospective review of prospectively maintained databases at 8 academic institutions from 2009 to 2016 was performed to identify patients with posterior circulation aneurysms treated with the Pipeline Embolization Device. Branch coverage following placement was evaluated, including the posterior inferior cerebellar artery, anterior inferior cerebellar artery, superior cerebellar artery, and posterior cerebral artery. If the Pipeline Embolization Device crossed the ostia of the contralateral vertebral artery, its long-term patency was assessed as well. RESULTS: A cohort of 129 consecutive patients underwent treatment of 131 posterior circulation aneurysms with the Pipeline Embolization Device. Adjunctive coiling was used in 40 (31.0%) procedures. One or more branches were covered in 103 (79.8%) procedures. At a median follow-up of 11 months, 11% were occluded, most frequently the vertebral artery (34.8%). Branch obliteration was most common among asymptomatic aneurysms (P < .001). Ischemic complications occurred in 29 (22.5%) procedures. On multivariable analysis, there was no significant difference in ischemic complications in cases in which a branch was covered (P = .24) or occluded (P = .16). CONCLUSIONS: There was a low occlusion incidence in end arteries following branch coverage at last follow-up. The incidence was higher in the posterior cerebral artery and vertebral artery where collateral supply is high. Branch occlusion was not associated with a significant increase in ischemic complications.


Subject(s)
Brain Ischemia/epidemiology , Brain Ischemia/etiology , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/therapy , Adult , Aged , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Humans , Incidence , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Treatment Outcome
7.
AJNR Am J Neuroradiol ; 39(4): 734-741, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29449282

ABSTRACT

BACKGROUND AND PURPOSE: The ROI-dose-reduced intervention technique represents an extension of ROI fluoroscopy combining x-ray entrance skin dose reduction with spatially different recursive temporal filtering to reduce excessive image noise in the dose-reduced periphery in real-time. The aim of our study was to compare the image quality of simulated neurointerventions with regular and reduced radiation doses using a standard flat panel detector system. MATERIALS AND METHODS: Ten 3D-printed intracranial aneurysm models were generated on the basis of a single patient vasculature derived from intracranial DSA and CTA. The incident dose to each model was reduced using a 0.7-mm-thick copper attenuator with a circular ROI hole (10-mm diameter) in the middle mounted inside the Infinix C-arm. Each model was treated twice with a primary coiling intervention using ROI-dose-reduced intervention and regular-dose intervention protocols. Eighty images acquired at various intervention stages were shown twice to 2 neurointerventionalists who independently scored imaging qualities (visibility of aneurysm-parent vessel morphology, associated vessels, and/or devices used). Dose-reduction measurements were performed using an ionization chamber. RESULTS: A total integral dose reduction of 62% per frame was achieved. The mean scores for regular-dose intervention and ROI dose-reduced intervention images did not differ significantly, suggesting similar image quality. Overall intrarater agreement for all scored criteria was substantial (Kendall τ = 0.62887; P < .001). Overall interrater agreement for all criteria was fair (κ = 0.2816; 95% CI, 0.2060-0.3571). CONCLUSIONS: Substantial dose reduction (62%) with a live peripheral image was achieved without compromising feature visibility during neuroendovascular interventions.


Subject(s)
Angiography, Digital Subtraction/methods , Cerebral Angiography/methods , Intracranial Aneurysm/diagnostic imaging , Humans , Phantoms, Imaging , Radiation Dosage
8.
AJNR Am J Neuroradiol ; 38(12): 2270-2276, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29025724

ABSTRACT

BACKGROUND AND PURPOSE: Patient selection for endovascular therapy remains a great challenge in clinic practice. We sought to determine the effect of baseline CT and angiography on outcomes in the Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment for Acute Ischemic Stroke (SWIFT PRIME) trial and to identify patients who would benefit from endovascular stroke therapy. MATERIALS AND METHODS: The primary end point was a 90-day modified Rankin Scale score of 0-2. Subgroup and classification and regression tree analysis was performed on baseline ASPECTS, site of occlusion, clot length, collateral status, and onset-to-treatment time. RESULTS: Smaller baseline infarct (n = 145) (ASPECTS 8-10) was associated with better outcomes in patients treated with thrombectomy versus IV tPA alone (66% versus 41%; rate ratio, 1.62) compared with patients with larger baseline infarcts (n = 44) (ASPECTS 6-7) (42% versus 21%; rate ratio, 1.98). The benefit of thrombectomy over IV tPA alone did not differ significantly by ASPECTS. Stratification by occlusion location also showed benefit with thrombectomy across all groups. Improved outcomes after thrombectomy occurred in patients with clot lengths of ≥8 mm (71% versus 43%; rate ratio, 1.67). Outcomes stratified by collateral status had a benefit with thrombectomy across all groups: none-fair collaterals (33% versus 0%), good collaterals (58% versus 44%), and excellent collaterals (82% versus 28%). Using a 3-level classification and regression tree analysis, we observed optimal outcomes in patients with favorable baseline ASPECTS, complete/near-complete recanalization (TICI 2b/3), and early treatment (mean mRS, 1.35 versus 3.73), while univariate and multivariate logistic regression showed significantly better results in patients with higher ASPECTS. CONCLUSIONS: While benefit was seen with endovascular therapy across multiple subgroups, the greatest response was observed in patients with a small baseline core infarct, excellent collaterals, and early treatment.


Subject(s)
Patient Selection , Stroke/diagnostic imaging , Stroke/pathology , Aged , Aged, 80 and over , Computed Tomography Angiography , Endovascular Procedures/methods , Female , Humans , Male , Middle Aged , Regression Analysis , Stroke/surgery , Thrombectomy/methods , Tomography, X-Ray Computed , Treatment Outcome
9.
AJNR Am J Neuroradiol ; 38(12): 2295-2300, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28912285

ABSTRACT

BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device (PED) for the treatment of intracranial aneurysms is associated with a high rate of aneurysm occlusion. However, clinical and radiographic predictors of incomplete aneurysm occlusion are poorly defined. In this study, predictors of incomplete occlusion at last angiographic follow-up after PED treatment were assessed. MATERIALS AND METHODS: A retrospective analysis of consecutive aneurysms treated with the PED between 2009 and 2016, at 3 academic institutions in the United States, was performed. Cases with angiographic follow-up were selected to evaluate factors predictive of incomplete aneurysm occlusion at last follow-up. RESULTS: We identified 465 aneurysms treated with the PED; 380 (81.7%) aneurysms (329 procedures; median age, 58 years; female/male ratio, 4.8:1) had angiographic follow-up, and were included. Complete occlusion (100%) was achieved in 78.2% of aneurysms. Near-complete (90%-99%) and partial (<90%) occlusion were collectively achieved in 21.8% of aneurysms and defined as incomplete occlusion. Of aneurysms followed for at least 12 months (211 of 380), complete occlusion was achieved in 83.9%. Older age (older than 70 years), nonsmoking status, aneurysm location within the posterior communicating artery or posterior circulation, greater aneurysm maximal diameter (≥21 mm), and shorter follow-up time (<12 months) were significantly associated with incomplete aneurysm occlusion at last angiographic follow-up on univariable analysis. However, on multivariable logistic regression, only age, smoking status, and duration of follow-up were independently associated with occlusion status. CONCLUSIONS: Complete occlusion following PED treatment of intracranial aneurysms can be influenced by several factors related to the patient, aneurysm, and treatment. Of these factors, older age (older than 70 years) and nonsmoking status were independent predictors of incomplete occlusion. While the physiologic explanation for these findings remains unknown, identification of factors predictive of incomplete aneurysm occlusion following PED placement can assist in patient selection and counseling and might provide insight into the biologic factors affecting endothelialization.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm/therapy , Treatment Outcome , Adult , Aged , Embolization, Therapeutic/instrumentation , Female , Humans , Male , Middle Aged , Retrospective Studies
10.
AJNR Am J Neuroradiol ; 38(8): 1605-1609, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28522668

ABSTRACT

BACKGROUND AND PURPOSE: Tandem aneurysms are defined as multiple aneurysms located in close proximity on the same parent vessel. Endovascular treatment of these aneurysms has rarely been reported. Our aim was to evaluate the safety and efficacy of a single Pipeline Embolization Device for the treatment of tandem aneurysms of the internal carotid artery. MATERIALS AND METHODS: A retrospective analysis of consecutive aneurysms treated with the Pipeline Embolization Device between 2009 and 2016 at 3 institutions in the United States was performed. Cases included aneurysms of the ICA treated with a single Pipeline Embolization Device, and they were divided into tandem versus solitary. Angiographic and clinical outcomes were compared. RESULTS: The solitary group (median age, 58 years) underwent 184 Pipeline Embolization Device procedures for 184 aneurysms. The tandem group (median age, 50.5 years) underwent 34 procedures for 78 aneurysms. Aneurysms were primarily located along the paraophthalmic segment of the ICA in both the single and tandem groups (72.3% versus 78.2%, respectively, P = .53). The median maximal diameters in the solitary and tandem groups were 6.2 and 6.7 mm, respectively. Complete occlusion on the last angiographic follow-up was achieved in 75.1% of aneurysms in the single compared with 88.6%% in the tandem group (P = .06). Symptomatic thromboembolic complications were encountered in 2.7% and 8.8% of procedures in the single and tandem groups, respectively (P = .08). CONCLUSIONS: Tandem aneurysms of the ICA can be treated with a single Pipeline Embolization Device with high rates of complete occlusion. While there appeared to be a trend toward higher thromboembolic complication rates, this did not reach statistical significance.


Subject(s)
Carotid Artery Diseases/therapy , Carotid Artery, Internal/diagnostic imaging , Embolization, Therapeutic/instrumentation , Embolization, Therapeutic/methods , Intracranial Aneurysm/therapy , Adult , Aged , Aged, 80 and over , Carotid Artery Diseases/diagnostic imaging , Cerebral Angiography , Embolization, Therapeutic/adverse effects , Female , Humans , Intracranial Aneurysm/diagnostic imaging , Intraoperative Complications/epidemiology , Male , Middle Aged , Postoperative Complications/epidemiology , Retrospective Studies , Safety , Treatment Outcome , Young Adult
11.
AJNR Am J Neuroradiol ; 37(6): 1127-31, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26767709

ABSTRACT

Flow diversion to treat cerebral aneurysms has revolutionized neurointerventional surgery. Because the addition of coils potentially increases the time and complexity of endovascular procedures, we sought to determine whether adjunctive coil use is associated with an increase in complications. Patients in the International Retrospective Study of Pipeline Embolization Device registry were divided into those treated with the Pipeline Embolization Device alone (n = 689 patients; n = 797 aneurysms; mean aneurysm size, 10.3 ± 7.6 mm) versus those treated with the Pipeline Embolization Device and concurrent coil embolization (n = 104 patients; n = 109 aneurysms; mean aneurysm size, 13.6 ± 7.8 mm). Patient demographics and aneurysm characteristics were examined. Rates of neurologic morbidity and mortality were compared between groups. The Pipeline Embolization Device with versus without coiling required a significantly longer procedure time (135.8 ± 63.9 versus 96.7 ± 46.2 min; P < .0001) and resulted in higher neurological morbidity (12.5% versus 7.8%; P = .13). These data suggest that either strategy represents an acceptable risk profile in the treatment of complex cerebral aneurysms and warrants further investigation.


Subject(s)
Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Blood Vessel Prosthesis , Female , Humans , Male , Middle Aged , Registries , Retrospective Studies , Treatment Outcome
12.
AJNR Am J Neuroradiol ; 37(4): 667-72, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26564442

ABSTRACT

BACKGROUND AND PURPOSE: Mechanical thrombectomy is beneficial for patients with acute ischemic stroke and a proximal anterior occlusion, but it is unclear if these results can be extrapolated to patients with an M2 occlusion. The purpose of this study was to examine the technical aspects, safety, and outcomes of mechanical thrombectomy with a stent retriever in patients with an isolated M2 occlusion who were included in 3 large multicenter prospective studies. MATERIALS AND METHODS: We included patients from the Solitaire Flow Restoration Thrombectomy for Acute Revascularization (STAR), Solitaire With the Intention For Thrombectomy (SWIFT), and Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment (SWIFT PRIME) studies, 3 large multicenter prospective studies on thrombectomy for ischemic stroke. We compared outcomes and technical details of patients with an M2 with those with an M1 occlusion. All patients were treated with a stent retriever. Imaging data and outcomes were scored by an independent core laboratory. Successful reperfusion was defined as modified Thrombolysis in Cerebral Infarction score of 2b/3. RESULTS: We included 50 patients with an M2 and 249 patients with an M1 occlusion. Patients with an M2 occlusion were older (mean age, 71 versus 67 years; P = .04) and had a lower NIHSS score (median, 13 versus 17; P < .001) compared with those with an M1 occlusion. Procedural time was nonsignificantly shorter in patients with an M2 occlusion (median, 29 versus 35 minutes; P = .41). The average number of passes with a stent retriever was also nonsignificantly lower in patients with an M2 occlusion (mean, 1.4 versus 1.7; P = .07). There were no significant differences in successful reperfusion (85% versus 82%, P = .82), symptomatic intracerebral hemorrhages (2% versus 2%, P = 1.0), device-related serious adverse events (6% versus 4%, P = .46), or modified Rankin Scale score 0-2 at follow-up (60% versus 56%, P = .64). CONCLUSIONS: Endovascular reperfusion therapy appears to be feasible in selected patients with ischemic stroke and an M2 occlusion.


Subject(s)
Infarction, Middle Cerebral Artery/surgery , Thrombectomy/methods , Aged , Aged, 80 and over , Animals , Brain Ischemia/surgery , Cerebral Hemorrhage/epidemiology , Cerebral Revascularization/methods , Dogs , Female , Humans , Infarction, Middle Cerebral Artery/pathology , Male , Middle Aged , Multicenter Studies as Topic , Postoperative Complications/epidemiology , Prospective Studies , Reperfusion , Stents/adverse effects , Stroke/surgery , Thrombectomy/adverse effects , Treatment Outcome
13.
Article in English | MEDLINE | ID: mdl-26683822

ABSTRACT

Acute ischemic stroke (AIS) is the leading cause of long-term disability and the second cause of death worldwide. Intravenous (IV) tissue plasminogen activator (tPA) remains the only FDA-approved treatment for AIS. The use of IV tPA in AIS related to large-vessel occlusion (LVO) has shown low recanalization rates and poor clinical outcomes. Over the last decade, endovascular treatment has demonstrated safety and effectiveness in the management of LVO-associated AIS due to the evolution of endovascular techniques and technologies, beginning with intraarterial thrombolysis, aspiration, self- expanding intracranial stents, and now retrievable stents. With the recent publication of the results of 5 randomized controlled studies, mechanical thrombectomy in combination with IV tPA demonstrated significant radiographic and clinical benefit over traditional strategies with IV tPA alone. In light of these results, endovascular therapy has been placed at the forefront of stroke treatment, redefining the standard of care. This review presents the evolution of endovascular treatment of AIS resulting from LVO; provides an analysis of the initial and latest RCTs; and discusses the association between endovascular mechanical thrombectomy and clinical outcomes, functional outcomes, and rates of revascularization, intracranial hemorrhage, morbidity, and mortality. Finally, shortcomings of the recent technological advances, such as clot fragmentation, and potential solutions to overcome these drawbacks are presented.

14.
J Neurosurg Sci ; 59(1): 63-71, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25423134

ABSTRACT

Carotid artery revascularization is an effective means of stroke prevention in selected patients with carotid stenosis. Traditionally, carotid endarterectomy (CEA) was performed to achieve this goal. With the development of endovascular techniques and technologies, carotid artery stenting (CAS) has become a viable alternative to CEA, particularly in patients considered high risk for CEA. The Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy (SAPPHIRE) study single-handedly catapulted CAS to the forefront of therapeutic options for high-risk patients. This study directly compared CAS to CEA in high-risk patients, finding CAS to be equally effective. Since SAPPHIRE, several studies have confirmed the safety and efficacy of CAS in high-risk patients, demonstrating acceptable 1-year morbidity (1-11.3%) and durable target-vessel patency (97.6-98.7%).


Subject(s)
Carotid Stenosis/surgery , Cerebral Revascularization/methods , Endarterectomy, Carotid , Humans , Stents , Treatment Outcome
15.
AJNR Am J Neuroradiol ; 36(3): 547-51, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25376809

ABSTRACT

BACKGROUND AND PURPOSE: A new in vitro cerebrovascular occlusion model of the intracranial circulation was developed recently for testing thrombectomy devices. Using this model, we compared recanalization success associated with different modern endovascular thrombectomy approaches. MATERIALS AND METHODS: Model experiments were performed in 4 thrombectomy test groups: 1) primary or direct Stentriever thrombectomy with a conventional guide catheter (control group), 2) primary Stentriever thrombectomy with a balloon-guide catheter, 3) combined Stentriever-continuous aspiration approach, and 4) direct aspiration alone. Successful recanalization was defined as a TICI score of 2b or 3. RESULTS: Seventy-one thrombectomy experiments were conducted. Similar rates of TICI 2b-3 scores were achieved with balloon-guide and conventional guide catheters (P = .34). The combined Stentriever plus aspiration approach and the primary aspiration thrombectomy resulted in significantly higher rates of TICI 2b or 3 than the conventional guide-catheter approach in the control group (P = .008 and P = .0001, respectively). The primary Stentriever thrombectomy with the conventional guide catheter showed the highest rate of embolization to new territories (53%). CONCLUSIONS: Data from our in vitro model experiments show that the Stentriever thrombectomy under continuous aspiration and primary aspiration thrombectomy approaches led to the highest degree of recanalization.


Subject(s)
Intracranial Thrombosis/surgery , Stroke/surgery , Thrombectomy/methods , Female , Humans , Thrombectomy/instrumentation , Treatment Outcome
16.
Int J Stroke ; 9(5): 658-68, 2014 Jul.
Article in English | MEDLINE | ID: mdl-23130938

ABSTRACT

RATIONALE: Self-expanding stent retrievers are a promising new device class designed for rapid flow restoration in acute cerebral ischaemia. The SOLITAIRE™ Flow Restoration device (SOLITAIRE) has shown high rates of recanalization in preclinical models and in uncontrolled clinical series. AIMS: (1) To demonstrate non-inferiority of SOLITAIRE compared with a legally marketed device, the MERCI Retrieval System®; (2) To demonstrate safety, feasibility, and efficacy of SOLITAIRE in subjects requiring mechanical thrombectomy diagnosed with acute ischaemic stroke. DESIGN : Multicenter, randomized, prospective, controlled trial with blinded primary end-point ascertainment. STUDY PROCEDURES: Key entry criteria include: age 22-85; National Institute of Health Stroke Scale (NIHSS) ≥8 and <30; clinical and imaging findings consistent with acute ischaemic stroke; patient ineligible or failed intravenous tissue plasminogen activator; accessible occlusion in M1 or M2 middle cerebral artery, internal carotid artery, basilar artery, or vertebral artery; and patient able to be treated within 8 h of onset. Sites first participate in a roll-in phase, treating two patients with the SOLITAIRE device, before proceeding to the randomized phase. In patients unresponsive to the initially assigned therapy, after the angiographic component of the primary end-point is ascertained (reperfusion with the initial assigned device), rescue therapy with other reperfusion techniques is permitted. OUTCOMES: The primary efficacy end-point is successful recanalization with the assigned study device (no use of rescue therapy) and with no symptomatic intracranial haemorrhage. Successful recanalization is defined as achieving Thrombolysis In Myocardial Ischemia 2 or 3 flow in all treatable vessels. The primary safety end-point is the incidence of device-related and procedure-related serious adverse events. A major secondary efficacy end-point is time to achieve initial recanalization. Additional secondary end-points include clinical outcomes at 90 days and radiologic haemorrhagic transformation.


Subject(s)
Brain Ischemia/surgery , Clinical Protocols , Stents , Stroke/surgery , Thrombectomy/instrumentation , Brain/diagnostic imaging , Brain/surgery , Brain Ischemia/diagnostic imaging , Humans , Outcome Assessment, Health Care/methods , Patient Selection , Prospective Studies , Radiography , Stents/adverse effects , Stroke/diagnostic imaging , Thrombectomy/adverse effects , Thrombectomy/methods
17.
AJNR Am J Neuroradiol ; 33(9): E117-9, 2012 Oct.
Article in English | MEDLINE | ID: mdl-21757517

ABSTRACT

The Outreach DAC is an intermediate-sized catheter designed for use with the Merci clot retriever in acute stroke. We investigated its utility as an adjunctive device during AVM pedicle embolization. In the authors' opinion, the DAC provided additional guide-catheter and microcatheter support, improved selective angiographic visualization of AVM angioarchitecture, aided microcatheter removal from its embedded position in the AVM Onyx cast, and enhanced local microcatheter control and safety, compared with embolization with the guide and microcatheter alone.


Subject(s)
Embolization, Therapeutic/instrumentation , Intracranial Arteriovenous Malformations/therapy , Polyvinyls/administration & dosage , Tantalum/administration & dosage , Vascular Access Devices , Drug Combinations , Embolization, Therapeutic/methods , Equipment Design , Equipment Failure Analysis , Hemostatics/administration & dosage , Humans , Male , Miniaturization , Treatment Outcome , Young Adult
18.
AJNR Am J Neuroradiol ; 32(8): 1399-407, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21757527

ABSTRACT

BACKGROUND AND PURPOSE: The self-expanding V-POD is a second-generation flow-diverting device with a low-porosity PTFE patch on a self-expanding microstent. The authors evaluated this device for the treatment of elastase-induced aneurysms in rabbits. MATERIALS AND METHODS: Three V-POD types (A, circumferential patch closed-cell stent [n = 9]; B, asymmetric patch closed-cell stent [n = 7]; and C, asymmetric patch open-cell stent [n = 4]) were evaluated by using angiography, conebeam micro-CT, histology, and SEM. Aneurysm flow modifications were expressed in terms of immediate poststent/prestent ratios of maximum CA volume entering the aneurysm dome tracked on procedural angiograms. Flow modifications were correlated with 4 weeks' follow-up angiographic, micro-CT, histologic, and SEM results. RESULTS: Mechanical stent-deployment difficulties in 4 aneurysms (1 type A; 3 type B) led to suboptimal results and exclusion from analysis. Of the remaining 16 aneurysms, 4-week post-treatment angiograms showed no aneurysm filling in 10 (63%), 3 (∼19%) had no filling with a small remnant neck, and 3 (∼19%) had <0.25 filling. Successfully treated aneurysms (n = 16) demonstrated an immediate poststent/prestent CA maximum volume ratio of 0.13 ± 0.18% (0.0%-0.5%). Favorable contrast-flow modification on immediate angiography after deployment correlated significantly with aneurysm occlusion on follow-up angiography, micro-CT, and histology. The occlusion percentage derived from micro-CT was 96 ± 6.8%. Histology indicated advanced healing (grade ≥3) in the aneurysm dome in 13 of 16 cases. SEM revealed 15 of 16 stents in an advanced state of endothelialization. CONCLUSIONS: This study showed the feasibility and effectiveness of V-POD for aneurysm healing in a rabbit elastase model.


Subject(s)
Intracranial Aneurysm/surgery , Stents , Animals , Disease Models, Animal , Equipment Design , Intracranial Aneurysm/chemically induced , Pancreatic Elastase/administration & dosage , Porosity , Rabbits
19.
J Neurosurg Sci ; 55(2): 151-60, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21623327

ABSTRACT

Endovascular intraarterial (IA) strategies have emerged as important treatment options for patients with acute ischemic stroke who are ineligible for intravenous (IV) tissue plasminogen activator (tPA) or in whom such therapy has failed. The goal of this article is to provide a comprehensive review of percutaneous IA endovascular techniques aimed at revascularization in the setting of acute ischemic stroke from IA thrombolysis, mechanical thrombectomy, and primary intracranial stenting to retrievable-stent technology. For each modality, we focus on the existing clinical data, including our institutional experience and techniques.


Subject(s)
Angioplasty/methods , Brain Ischemia/surgery , Stents , Stroke/surgery , Thrombectomy/methods , Thrombolytic Therapy/methods , Acute Disease , Brain Ischemia/diagnostic imaging , Brain Ischemia/therapy , Humans , Infusions, Intra-Arterial , Radiography , Stroke/diagnostic imaging , Stroke/therapy
20.
AJNR Am J Neuroradiol ; 30(8): 1532-3, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19279279

ABSTRACT

Intracranial stent placement is emerging as an effective treatment for acute stroke. As a means to avoid stent-associated complications and capitalize on stent-placement-related advantages, the concept of a "temporary endovascular bypass" (TEB) for stroke therapy was recently reported. In this technique, a stent is temporarily deployed for instant recanalization. Once sufficient flow is established to maintain vessel patency, the stent is recaptured and withdrawn. We report a second case to further characterize the merits of TEB.


Subject(s)
Blood Vessel Prosthesis , Stents , Stroke/surgery , Vascular Surgical Procedures/instrumentation , Vascular Surgical Procedures/methods , Acute Disease , Adult , Device Removal/methods , Humans , Male , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...