EuroIntervention ; 16(11): e922-e929, 2020 Dec 04.
Article in English | MEDLINE | ID: mdl-32583804

ABSTRACT

AIMS: Neoatherosclerosis is a frequent finding after implantation of permanent metallic stents. Bioresorbable scaffolds (BRS) are considered to reduce the incidence of neoatherosclerosis owing to their dissolution and consequent vascular restoration. The aim of this study was to evaluate the formation of neoatherosclerosis between magnesium-based BRS and thick-strut metallic drug-eluting stents (DES) in a rabbit model of neoatherosclerosis and in proportion to the effect of high-dose statin medication. METHODS AND RESULTS: Fully bioresorbable magnesium scaffolds (BRS, n=45) and thick-strut permanent metallic DES of equivalent geometry and design (n=45) were implanted into the iliac arteries of New Zealand White rabbits (n=45) following endothelial balloon injury and exposure to a cholesterol diet. Endothelialisation was assessed in 12 animals after 35 days using scanning electron microscopy (SEM), showing significantly enhanced re-endothelialisation above struts in the BRS (n=13) compared to DES (n=10). Eleven (11) animals were terminated for baseline assessment after 91 days while the remaining 22 animals were randomised to receive high-dose statin treatment (3 mg/kg) or placebo. BRS-treated vessels showed a significant reduction in foam cell infiltration as a sign of early neoatherosclerosis by histology and OCT when compared to thick-strut DES-treated vessels. Statin treatment resulted in significant reduction of foam cell infiltration in BRS and DES by histology. CONCLUSIONS: Our findings suggest reduced neoatherosclerosis formation in magnesium-based BRS relative to thick-strut DES. High-dose statin treatment may be a promising measure to reduce neoatherosclerosis progression, both on its own and in synergy with site-targeted device-based treatment.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Animals , Coronary Vessels , Magnesium , Prosthesis Design , Rabbits , Stents , Tomography, Optical Coherence
2.
JACC Cardiovasc Interv ; 11(14): 1340-1350, 2018 07 23.
Article in English | MEDLINE | ID: mdl-30025727

ABSTRACT

OBJECTIVES: The purpose of this study was to assess neoatherosclerosis in a registry of prospectively enrolled patients presenting with stent thrombosis using optical coherence tomography. BACKGROUND: In-stent neoatherosclerosis was recently identified as a novel disease manifestation of atherosclerosis after coronary stent implantation. METHODS: Angiography and intravascular optical coherence tomography were used to investigate etiologic factors of neoatherosclerosis in patients presenting with stent thrombosis >1 year after implantation (very late stent thrombosis [VLST]). Clinical data were collected according to a standardized protocol. Optical coherence tomographic acquisitions were analyzed in a core laboratory. Cox regression analysis was performed to identify factors associated with the formation of neoatherosclerosis and plaque rupture as a function of time. RESULTS: Optical coherence tomography was performed in 134 patients presenting with VLST. A total of 58 lesions in 58 patients with neoatherosclerosis were compared with 76 lesions in 76 patients without neoatherosclerosis. Baseline characteristics were similar between groups. In-stent plaque rupture was the most frequent cause (31%) in all patients presenting with VLST. In patients with neoatherosclerosis, in-stent plaque rupture was identified as the cause of VLST in 40 cases (69%), whereas uncovered stent struts (n = 22 [29%]) was the most frequent cause in patients without neoatherosclerosis. Macrophage infiltration was significantly more frequent in optical coherence tomographic frames with plaque rupture compared with those without (50.2% vs. 22.2%; p < 0.0001), whereas calcification was more often observed in frames without plaque rupture (17.2% vs. 4%; p < 0.0001). Implantation of a drug-eluting stent was significantly associated with the formation of neoatherosclerosis (p = 0.02), whereas previous myocardial infarction on index percutaneous coronary intervention was identified as a significant risk factor for plaque rupture in patients with neoatherosclerosis (p = 0.003). No significant difference was observed in thrombus composition between patients with or without neoatherosclerosis. CONCLUSIONS: Neoatherosclerosis was frequently observed in patients with VLST. Implantation of a drug-eluting stent was significantly associated with neoatherosclerosis formation. In-stent plaque rupture was the prevailing pathological mechanism and often occurred in patients with neoatherosclerosis and previous myocardial infarction at index percutaneous coronary intervention. Increased macrophage infiltration heralded plaque vulnerability in our study and might serve as an important indicator.


Subject(s)
Coronary Artery Disease/therapy , Coronary Thrombosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Stents , Tomography, Optical Coherence , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Thrombosis/pathology , Coronary Vessels/pathology , Drug-Eluting Stents , Europe , Female , Humans , Male , Metals , Middle Aged , Neointima , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Rupture, Spontaneous , Time Factors