Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 113
Filter
1.
J Periodontal Res ; 52(1): 122-126, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27018040

ABSTRACT

BACKGROUND AND OBJECTIVE: Periodontal disease has been described as playing a role in the atherosclerosis process, and its relation with intimal thickness and vascular endothelial function (EF) has been investigated. The present study sought to determine whether there are differences in parameters of arterial stiffness and EF between patients with and without severe periodontal disease (SPD). MATERIAL AND METHODS: Patients referred to the School of Dentistry University of Buenos Aires, were assessed. Demographic characteristics, atherogenic risk factors and concomitant pathologies were recorded. Patients with known cardiovascular pathology were excluded. Using carotid Doppler ultrasound an operator assessed arterial stiffness parameters: compliance, elastic modulus (EM), ß stiffness index (ßSI) and vascular EF by brachial artery flow-mediated dilatation. The patients were divided into two groups: with and without SPD. RESULTS: Forty patients were included; 60% were women; 15 were in the SPD group and 25 in the group without SPD. Respective results of the studied variables were: age 56.53 ± 17.58 vs. 51.12 ± 12.97 years (NS); probing depth 2.53 ± 1.30 (95% CI 1.81-3.25) vs. 1.25 ± 0.51 (95% CI 1.31-1.73) p = 0.02; clinical attachment level 4.80 ± 2.00 (95% CI 3.69-5.91) vs. 1.72 ± 0.93 (95% CI 1.33-2.11) p = 0.001; intimal thickness 0.10 ± 0.17 (95% CI 0.095-0.11) vs. 0.82 ± 0.18 (95% CI 0.074-0.98) (NS); EM 48.33 ± 12.53 vs. 38.86 ± 7.69 (p = 0.005); ßSI 4.21 ± 1.03 vs. 3.64 ± 1.02 (p = 0.004); EF 16.13 ± 5.02 vs. 22.76 ± 4.50 (p = 0.0003). Correlation between: EM and clinical attachment level r = 0.58 (p < 0.001), ßSI and clinical attachment level r = 0.66 (p < 0.001), EF and clinical attachment level 0.59 (p < 0.001). CONCLUSIONS: Parameters of arterial stiffness and EF were worse in patients with SPD and correlated moderately with clinical attachment level. Correlation with compliance and EF was negative.


Subject(s)
Periodontal Diseases/complications , Vascular Stiffness , Alveolar Bone Loss/complications , Alveolar Bone Loss/diagnostic imaging , Case-Control Studies , Female , Humans , Male , Middle Aged , Periodontal Attachment Loss/complications , Prospective Studies , Radiography, Dental
2.
Ultrasonics ; 54(8): 2099-108, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25041980

ABSTRACT

This study aims to bridge the gap between transport mechanisms of an improved ultrasound contrast agent (UCA) and its resulting behavior in a clinical imaging study. Phospholipid-shelled microbubbles nested within the aqueous core of a polymer microcapsule are examined for their use and feasibility as an improved UCA. The nested formulation provides contrast comparable to traditional formulations, specifically an SF6 microbubble coated by a DSPC PEG-3000 monolayer, with the advantage that contrast persists at least nine times longer in a mock clinical, in vitro setting. The effectiveness of the sample was measured using a contrast ratio in units of decibels (dB) which compares the brightness of the nested microbubbles to a reference value of a phantom tissue mimic. During a 40min imaging study, six nesting formulations with average outer capsule diameters of 1.95, 2.53, 5.55, 9.95, 14.95, and 20.51µm reached final contrast ratio values of 0.25, 2.35, 3.68, 4.51, 5.93, and 8.00dB, respectively. The starting contrast ratio in each case was approximately 8dB and accounts for the brightness attributed to the nesting shell. As compared with empty microcapsules (no microbubbles nested within), enhancement of the initial contrast ratio increased systematically with decreasing microcapsule size. The time required to reach a steady state in the temporal contrast ratio profile also varied with microcapsule diameter and was found to be 420s for each of the four smallest shell diameters and 210s and 150s, respectively, for the largest two shell diameters. All nested formulations were longer-lived and gave higher final contrast ratios than a control sample comprising un-nested, but otherwise equivalent, microbubbles. Specifically, the contrast ratio of the un-nested microbubbles decreased to a negative value after 4min of continuous ultrasound exposure with complete disappearance of the microbubbles after 15min whereas all nested formulations maintained positive contrast ratio values for the duration of the 40min trial. The results are consistent with two distinct stages of gas transport: in the first stage, passive diffusion occurs under ambient conditions across the microbubble monolayer within the first few minutes after formulation until the aqueous interior of the microcapsule is saturated with gas; in the second stage ultrasound drives additional gas dissolution even further due to pressure modulation. It is important to understand the chemistry and transport mechanisms of this contrast agent under the influence of ultrasound to attain better perspicacity for enhanced applications in imaging. Results from this study will facilitate future preclinical studies and clinical applications of nested microbubbles for therapeutic and diagnostic imaging.


Subject(s)
Contrast Media/chemistry , Microbubbles , Phosphatidylethanolamines/chemistry , Ultrasonics , Phantoms, Imaging , Polymers/chemistry , Transducers
3.
Ultrasonics ; 53(2): 570-9, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23131337

ABSTRACT

The paper presents the modified multi-element synthetic transmit aperture (MSTA) method for ultrasound imaging. It is based on coherent summation of RF echo signals with apodization weights taking into account the finite size of the transmit subaperture and of the receive element. The work presents extension of the previous study where the modified synthetic transmit aperture (STA) method was considered and verified [1]. In the case of MSTA algorithm the apodization weights were calculated for each imaging point and all combinations of the transmit subaperture and receive element using their angular directivity functions (ADFs). The ADFs were obtained from the exact solution of the corresponding mixed boundary-value problem for periodic baffle system modeling the transducer array. Performance of the developed method was tested using Field II simulated synthetic aperture data of point reflectors for 4MHz 128-element transducer array with 0.3mm pitch and 0.02mm kerf to estimate the visualization depth and lateral resolution. Also experimentally determined data of the tissue-mimicking phantom (Dansk Fantom Service, model 571) obtained using 128 elements, 4MHz, linear transducer array (model L14-5/38) and Ultrasonix SonixTOUCH Research platform were used for qualitative assessment of imaging contrast improvement. Comparison of the results obtained by the modified and conventional MSTA algorithms indicated 15dB improvement of the noise reduction in the vicinity of transducer's surface (1mm depth), and concurrent increase in the visualization depth (86% augment of the scattered amplitude at the depth of 90mm). However, this increase was achieved at the expense of minor degradation of the lateral resolution of approximately 8% at the depth of 50mm and 5% at the depth of 90mm.


Subject(s)
Ultrasonography/methods , Phantoms, Imaging
4.
Ultrasonics ; 52(4): 475-81, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22225594

ABSTRACT

The purpose of this work was to evaluate ultrasound modality as a non-invasive tool for determination of impact of the degree of the atherosclerotic plaque located in human internal carotid arteries on the values of the parameters of the pulse wave. Specifically, the applicability of the method to such arteries as brachial, common, and internal carotid was examined. The method developed is based on analysis of two characteristic parameters: the value of the mean reflection coefficient modulus |Γ|(a) of the blood pressure wave and time delay Δt between the forward (travelling) and backward (reflected) blood pressure waves. The blood pressure wave was determined from ultrasound measurements of the artery's inner (internal) diameter, using the custom made wall tracking system (WTS) operating at 6.75 MHz. Clinical data were obtained from the carotid arteries measurements of 70 human subjects. These included the control group of 30 healthy individuals along with the patients diagnosed with the stenosis of the internal carotid artery (ICA) ranging from 20% to 99% or with the ICA occlusion. The results indicate that with increasing level of stenosis of the ICA the value of the mean reflection coefficient measured in the common carotid artery, significantly increases from |Γ|(a)=0.45 for healthy individuals to |Γ|(a)=0.61 for patients with stenosis level of 90-99%, or ICA occlusion. Similarly, the time delay Δt decreases from 52 ms to 25 ms for the respective groups. The method described holds promise that it might be clinically useful as a non-invasive tool for localization of distal severe artery narrowing, which can assist in identifying early stages of atherosclerosis especially in regions, which are inaccessible for the ultrasound probe (e.g. carotid sinus or middle cerebral artery).


Subject(s)
Brachial Artery/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Ultrasonography, Doppler/methods , Aged , Aged, 80 and over , Blood Pressure , Brachial Artery/physiopathology , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/physiopathology , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/physiopathology , Case-Control Studies , Elastic Modulus , Feasibility Studies , Female , Humans , Male , Middle Aged , Models, Statistical , Plaque, Atherosclerotic/physiopathology , Statistics, Nonparametric
5.
Ultrasonics ; 52(2): 333-42, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21999938

ABSTRACT

The modified synthetic transmit aperture (STA) algorithm is described. The primary goal of this work was to assess the possibility to improve the image quality achievable using synthetic aperture (SA) approach and to evaluate the performance and the clinical applicability of the modified algorithm using phantoms. The modified algorithm is based on the coherent summation of back-scattered RF echo signals with weights calculated for each point in the image and for all possible combinations of the transmit-receive pairs. The weights are calculated using the angular directivity functions of the transmit-receive elements, which are approximated by a far-field radiation pattern of a narrow strip transducer element vibrating with uniform pressure amplitude over its width. In this way, the algorithm takes into account the finite aperture of each individual element in the imaging transducer array. The performance of the approach developed was tested using FIELD II simulated synthetic aperture data of the point reflectors, which allowed the visualization (penetration) depth and lateral resolution to be estimated. Also, both simulated and measured data of cyst phantom were used for qualitative assessment of the imaging contrast improvement. The experimental data were obtained using 128 elements, 4MHz, linear transducer array of the Ultrasonix research platform. The comparison of the results obtained using the modified and conventional (unweighted) STA algorithms revealed that the modified STA exhibited an increase in the penetration depth accompanied by a minor, yet discernible upon the closer examination, degradation in lateral resolution, mainly in the proximity of the transducer aperture. Overall, however, a considerable (12dB) improvement in the image quality, particularly in the immediate vicinity of the transducer's surface was demonstrated. The modified STA method holds promise to be of clinical importance, especially in the applications where the quality of the "near-field" image, that is the image in the immediate vicinity of the scanhead is of critical importance such as for instance in skin- and breast-examinations.


Subject(s)
Ultrasonography/methods , Algorithms , Biomedical Enhancement , Contrast Media , Microbubbles , Polyvinyl Alcohol
6.
J Electromyogr Kinesiol ; 20(3): 465-76, 2010 Jun.
Article in English | MEDLINE | ID: mdl-19811934

ABSTRACT

An inability to perform tasks involving reaching is a common problem for stroke patients. This paper provides an insight into mechanisms associated with recovery of upper limb function by examining how stroke participants' upper limb muscle activation patterns differ from those of neurologically intact participants, and how they change in response to an intervention. In this study, five chronic stroke participants undertook nine tracking tasks in which trajectory (orientation and length), speed and resistance to movement were varied. During these tasks, EMG signals were recorded from triceps, biceps, anterior deltoid, upper, middle and lower trapezius and pectoralis major. Data collection was performed in sessions both before, and after, an intervention in which participants performed a similar range of tracking tasks with the addition of responsive electrical stimulation applied to their triceps muscle. The intervention consisted of eighteen one hour treatment sessions, with two participants attending an additional seven sessions. During all sessions, each participant's arm was supported by a hinged arm-holder which constrained their hand to move in a two dimensional plane. Analysis of the pre intervention EMG data showed that timing and amplitude of peak EMG activity for all stroke participants differed from neurologically intact participants. Analysis of post intervention EMG data revealed that statistically significant changes in these quantities had occurred towards those of neurologically intact participants.


Subject(s)
Elbow Joint/physiopathology , Muscle Contraction , Muscle, Skeletal/physiopathology , Shoulder Joint/physiopathology , Stroke/physiopathology , Task Performance and Analysis , Adult , Aged , Female , Humans , Male , Middle Aged , Movement
7.
Neurorehabil Neural Repair ; 23(6): 559-68, 2009.
Article in English | MEDLINE | ID: mdl-19190087

ABSTRACT

BACKGROUND: An inability to perform tasks involving reaching is a common problem following stroke. Evidence supports the use of robotic therapy and functional electrical stimulation (FES) to reduce upper limb impairments, but current systems may not encourage maximal voluntary contribution from the participant because assistance is not responsive to performance. OBJECTIVE: This study aimed to investigate whether iterative learning control (ILC) mediated by FES is a feasible intervention in upper limb stroke rehabilitation. METHODS: Five hemiparetic participants with reduced upper limb function who were at least 6 months poststroke were recruited from the community. No participants withdrew. INTERVENTION: Participants undertook supported tracking tasks using 27 different trajectories augmented by responsive FES to their triceps brachii muscle, with their hand movement constrained in a 2-dimensional plane by a robot. Eighteen 1-hour treatment sessions were used with 2 participants receiving an additional 7 treatment sessions. OUTCOME MEASURES: The primary functional outcome measure was the Action Research Arm Test (ARAT). Impairment measures included the upper limb Fugl-Meyer Assessment (FMA), tests of motor control (tracking accuracy), and isometric force. RESULTS: Compliance was excellent and there were no adverse events. Statistically significant improvements were measured (P

Subject(s)
Electric Stimulation Therapy/methods , Motor Activity , Paresis/rehabilitation , Stroke Rehabilitation , Stroke/complications , Upper Extremity/physiopathology , Adult , Aged , Female , Humans , Male , Middle Aged , Paresis/etiology , Paresis/physiopathology , Recovery of Function , Robotics/methods , Robotics/statistics & numerical data , Stroke/physiopathology , Treatment Outcome
8.
Med Eng Phys ; 31(3): 364-73, 2009 Apr.
Article in English | MEDLINE | ID: mdl-18640865

ABSTRACT

An experimental test facility is developed for use by stroke patients in order to improve sensory-motor function of their upper limb. Subjects are seated at the workstation and their task is to repeatedly follow reaching trajectories that are projected onto a target above their arm. To do this they use voluntary control with the addition of electrical stimulation mediated by advanced control schemes applied to muscles in their impaired shoulder and arm. Full details of the design of the workstation and its periphery systems are given, together with a description of its use during the treatment of stroke patients.


Subject(s)
Exercise Therapy/methods , Robotics , Stroke Rehabilitation , Upper Extremity/physiopathology , Algorithms , Computer Simulation , Electric Stimulation Therapy/methods , Equipment Design , Exercise Therapy/instrumentation , Humans , Models, Statistical , Motor Skills , Recovery of Function , Reproducibility of Results , Software
9.
J Electromyogr Kinesiol ; 19(6): 1025-34, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19101167

ABSTRACT

An inability to perform tasks involving reaching is a common problem for stroke patients. Knowledge of normal muscle activation patterns during these tasks is essential to the identification of abnormal patterns in post-stroke hemiplegia. Findings will provide insight into changes in muscle activation patterns associated with recovery of upper limb function. In this study with neurologically intact participants the co-ordination of shoulder and elbow muscle activity during two dimensional reaching tasks is explored. Eight participants undertook nine tracking tasks in which trajectory (orientation and length), duration, speed and resistance to movement were varied. The participants' forearm was supported using a hinged arm-holder, which constrained their hand to move in a two dimensional plane. EMG signals were recorded from triceps, biceps, anterior deltoid, upper, middle and lower trapezius and pectoralis major. A wide variation in muscle activation patterns, in terms of timing and amplitude, was observed between participants performing the same task. EMG amplitude increased significantly with length, duration and resistance of the task for all muscles except anterior deltoid. Co-activation between biceps and triceps was significantly dependent on both task and trajectory orientation. Activation pattern of pectoralis major was dependent on trajectory. Neither trajectory orientation nor task condition affected the activation pattern of anterior deltoid. Normal ranges of timing of muscle activity during the tasks were identified.


Subject(s)
Elbow Joint/physiology , Movement/physiology , Muscle Contraction/physiology , Muscle, Skeletal/physiology , Psychomotor Performance/physiology , Shoulder Joint/physiology , Action Potentials/physiology , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
10.
Ultrasonics ; 49(3): 306-11, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19110289

ABSTRACT

The primary objective of this work was to develop and optimize the calibration techniques for ultrasonic hydrophone probes used in acoustic field measurements up to 100 MHz. A dependable, 100 MHz calibration method was necessary to examine the behavior of a sub-millimeter spatial resolution fiber optic (FO) sensor and assess the need for such a sensor as an alternative tool for high frequency characterization of ultrasound fields. Also, it was of interest to investigate the feasibility of using FO probes in high intensity fields such as those employed in HIFU (high intensity focused ultrasound) applications. In addition to the development and validation of a novel, 100 MHz calibration technique the innovative elements of this research include implementation and testing of a prototype FO sensor with an active diameter of about 10 microm that exhibits uniform sensitivity over the considered frequency range and does not require any spatial averaging corrections up to about 75 MHz. The results of the calibration measurements are presented and it is shown that the optimized calibration technique allows the sensitivity of the hydrophone probes to be determined as a virtually continuous function of frequency and is also well suited to verify the uniformity of the FO sensor frequency response. As anticipated, the overall uncertainty of the calibration was dependent on frequency and determined to be about +/-12% (+/-1 dB) up to 40 MHz, +/-20% (+/-1.5 dB) from 40 to 60 MHz and +/-25% (+/-2dB) from 60 to 100 MHz. The outcome of this research indicates that once fully developed and calibrated, the combined acousto-optic system will constitute a universal reference tool in the wide, 100 MHz bandwidth.


Subject(s)
Algorithms , Fiber Optic Technology/instrumentation , Image Interpretation, Computer-Assisted/methods , Optical Devices , Transducers , Ultrasonography/instrumentation , Fiber Optic Technology/standards , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography/standards , United States
11.
Ultrasonics ; 48(8): 707-15, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18474387

ABSTRACT

The primary goal of this work was to verify experimentally the applicability of the recently introduced time-averaged wave envelope (TAWE) method [J. Wójcik, A. Nowicki, P.A. Lewin, P.E. Bloomfield, T. Kujawska, L. Filipczynski, Wave envelopes method for description of nonlinear acoustic wave propagation, Ultrasonics 44 (2006) 310-329.] as a tool for fast prediction of four dimensional (4D) pulsed nonlinear pressure fields from arbitrarily shaped acoustic sources in attenuating media. The experiments were performed in water at the fundamental frequency of 2.8 MHz for spherically focused (focal length F=80 mm) square (20 x 20 mm) and rectangular (10 x 25mm) sources similar to those used in the design of 1D linear arrays operating with ultrasonic imaging systems. The experimental results obtained with 10-cycle tone bursts at three different excitation levels corresponding to linear, moderately nonlinear and highly nonlinear propagation conditions (0.045, 0.225 and 0.45 MPa on-source pressure amplitude, respectively) were compared with those yielded using the TAWE approach [J. Wójcik, A. Nowicki, P.A. Lewin, P.E. Bloomfield, T. Kujawska, L. Filipczynski, Wave envelopes method for description of nonlinear acoustic wave propagation, Ultrasonics 44 (2006) 310-329.]. The comparison of the experimental results and numerical simulations has shown that the TAWE approach is well suited to predict (to within+/-1 dB) both the spatial-temporal and spatial-spectral pressure variations in the pulsed nonlinear acoustic beams. The obtained results indicated that implementation of the TAWE approach enabled shortening of computation time in comparison with the time needed for prediction of the full 4D pulsed nonlinear acoustic fields using a conventional (Fourier-series) approach [P.T. Christopher, K.J. Parker, New approaches to nonlinear diffractive field propagation, J. Acoust. Soc. Am. 90 (1) (1991) 488-499.]. The reduction in computation time depends on several parameters, including the source geometry, dimensions, fundamental resonance frequency, excitation level as well as the strength of the medium nonlinearity. For the non-axisymmetric focused transducers mentioned above and excited by a tone burst corresponding to moderately nonlinear and highly nonlinear conditions the execution time of computations was 3 and 12h, respectively, when using a 1.5 GHz clock frequency, 32-bit processor PC laptop with 2 GB RAM memory, only. Such prediction of the full 4D pulsed field is not possible when using conventional, Fourier-series scheme as it would require increasing the RAM memory by at least 2 orders of magnitude.


Subject(s)
Acoustics , Ultrasonics , Calibration
12.
Ultrasonics ; 47(1-4): 64-73, 2007 Dec.
Article in English | MEDLINE | ID: mdl-17825338

ABSTRACT

In contrast to previously published papers [A. Nowicki, Z. Klimonda, M. Lewandowski, J. Litniewski, P.A. Lewin, I. Trots, Comparison of sound fields generated by different coded excitations - Experimental results, Ultrasonics 44 (1) (2006) 121-129; J. Litniewski, A. Nowicki, Z. Klimonda, M. Lewandowski, Sound fields for coded excitations in water and tissue: experimental approach, Ultrasound Med. Biol. 33 (4) (2007) 601-607], which examined the factors influencing the spatial resolution of coded complementary Golay sequences (CGS), this paper investigates the effect of ultrasound imaging transducer's fractional bandwidth on the gain of the compressed echo signal for different spectral widths of the CGS. Two different bit lengths were considered, specifically one and two cycles. Three transducers having fractional bandwidth of 25%, 58% and 80% and operating at frequencies 6, 4.4 and 6 MHz, respectively were examined (one of the 6 MHz sources was focused and made of composite material). The experimental results have shown that by increasing the code length, i.e. decreasing the bandwidth, the compressed echo amplitude could be enhanced. The smaller the bandwidth was the larger was the gain; the pulse-echo sensitivity of the echo amplitude increased by 1.88, 1.62 and 1.47, for 25%, 58% and 80% bandwidths, respectively. These results indicate that two cycles bit length excitation is more suitable for use with bandwidth limited commercially available imaging transducers. Further, the time resolution is retained for transducers with two cycles excitation providing the fractional bandwidth is lower than approximately 90%. The results of this work also show that adjusting the code length allows signal-to-noise-ratio (SNR) to be enhanced while using limited (less that 80%) bandwidth imaging transducers. Also, for such bandwidth limited transducers two cycles excitation would not decrease the time resolution, obtained with "conventional" spike excitation. Hence, CGS excitation could be successfully implemented with the existing, relatively narrow band imaging transducers without the need to use usually more expensive wideband, composite ones.


Subject(s)
Data Compression/methods , Signal Processing, Computer-Assisted/instrumentation , Transducers , Ultrasonography/instrumentation , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
13.
Ultrasonics ; 44(3): 310-29, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16780911

ABSTRACT

A novel, free from paraxial approximation and computationally efficient numerical algorithm capable of predicting 4D acoustic fields in lossy and nonlinear media from arbitrary shaped sources (relevant to probes used in medical ultrasonic imaging and therapeutic systems) is described. The new WE (wave envelopes) approach to nonlinear propagation modeling is based on the solution of the second order nonlinear differential wave equation reported in [J. Wójcik, J. Acoust. Soc. Am. 104 (1998) 2654-2663; V.P. Kuznetsov, Akust. Zh. 16 (1970) 548-553]. An incremental stepping scheme allows for forward wave propagation. The operator-splitting method accounts independently for the effects of full diffraction, absorption and nonlinear interactions of harmonics. The WE method represents the propagating pulsed acoustic wave as a superposition of wavelet-like sinusoidal pulses with carrier frequencies being the harmonics of the boundary tone burst disturbance. The model is valid for lossy media, arbitrarily shaped plane and focused sources, accounts for the effects of diffraction and can be applied to continuous as well as to pulsed waves. Depending on the source geometry, level of nonlinearity and frequency bandwidth, in comparison with the conventional approach the Time-Averaged Wave Envelopes (TAWE) method shortens computational time of the full 4D nonlinear field calculation by at least an order of magnitude; thus, predictions of nonlinear beam propagation from complex sources (such as phased arrays) can be available within 30-60 min using only a standard PC. The approximate ratio between the computational time costs obtained by using the TAWE method and the conventional approach in calculations of the nonlinear interactions is proportional to 1/N2, and in memory consumption to 1/N where N is the average bandwidth of the individual wavelets. Numerical computations comparing the spatial field distributions obtained by using both the TAWE method and the conventional approach (based on a Fourier series representation of the propagating wave) are given for circular source geometry, which represents the most challenging case from the computational time point of view. For two cases, short (2 cycle) and long (8 cycle) 2 MHz bursts, the computational times were 10 min and 15 min versus 2 h and 8 h for the TAWE method versus the conventional method, respectively.

14.
Ultrasonics ; 44(1): 121-9, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16313936

ABSTRACT

This work reports the results of measurements of spatial distributions of ultrasound fields obtained from five energizing schemes. Three different codes, namely, chirp signal and two sinusoidal sequences were investigated. The sequences were phase modulated with 13 bits Barker code and 16 bits Golay complementary codes. Moreover, two reference signals generated as two and sixteen cycle sine tone bursts were examined. Planar, 50% (fractional) bandwidth, 15 mm diameter source transducer operating at 2 MHz center frequency was used in all measurements. The experimental data were collected using computerized scanning system and recorded using wideband, PVDF membrane hydrophone (Sonora 804). The measured echoes were compressed, so the complete pressure field in the investigated location before and after compression could be compared. In addition to a priori anticipated increase in the signal to noise ratio (SNR) for the decoded pressure fields, the results indicated differences in the pressure amplitude levels, directivity patterns, and the axial distance at which the maximum pressure amplitude was recorded. It was found that the directivity patterns of non-compressed fields exhibited shapes similar to the patterns characteristic for sinusoidal excitation having relatively long time duration. In contrast, the patterns corresponding to compressed fields resembled those produced by brief, wideband pulses. This was particularly visible in the case of binary sequences. The location of the maximum pressure amplitude measured in the 2 MHz field shifted towards the source by 15 mm and 25 mm for Barker code and Golay code, respectively. The results of this work may be applicable in the development of new coded excitation schemes. They could also be helpful in optimizing the design of imaging transducers employed in ultrasound systems designed for coded excitation. Finally, they could shed additional light on the relationship between the spatial field distribution and achievable image quality and in this way facilitate optimization of the images obtained using coded systems.

15.
Ultrasonics ; 43(10): 815-21, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16054665

ABSTRACT

This work describes the results of initial evaluation of a wideband acousto-optic hydrophone probe designed to operate as point receiver in the frequency range up to 100 MHz. The hydrophone was implemented as a tapered fiber optic (FO) probe sensor with a tip diameter of approximately 7 microm. Such small physical dimensions of the sensor eliminate the need for spatial averaging corrections so that true pressure-time (p-t) waveforms can be faithfully recorded. The theoretical considerations that predicted the FO probe sensitivity to be equal to 4.3 mV/MPa are presented along with a brief description of the manufacturing process. The calibration results that verified the theoretically predicted sensitivity are also presented along with a brief description of the improvements being currently implemented to increase this sensitivity level by approximately 20 dB. The results of preliminary measurements indicate that the fiber optic probes will exhibit a uniform frequency response and a zero phase shift in the frequency range considered. These features might be very useful in rapid complex calibration i.e. determining both magnitude and phase response of other hydrophones by the substitution method. Also, because of their robust design and linearity, these fiber optic hydrophones could also meet the challenges posed by high intensity focused ultrasound (HIFU) and other therapeutic applications. Overall, the outcome of this work shows that when fully developed, the FO probes will be well suited for high frequency measurements of ultrasound fields and will be able to complement the data collected by the current finite aperture piezoelectric PVDF hydrophones.


Subject(s)
Acoustics , Optics and Photonics , Ultrasonics , Fiber Optic Technology , Models, Theoretical , Optical Fibers
16.
Ultrasonics ; 42(1-9): 367-72, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15047313

ABSTRACT

The influence of finite aperture and frequency response of piezoelectric ultrasonic hydrophone probes on the Thermal and Mechanical Indices was investigated using a comprehensive acoustic wave propagation model. The experimental verification of the model was obtained using a commercially available, 8 MHz, dynamically focused linear array and a single element, 5 MHz, focused rectangular source. The pressure-time waveforms were recorded using piezoelectric polymer hydrophone probes of different active element diameters and bandwidths. The nominal diameters of the probes ranged from 50 to 500 microm and their usable bandwidths varied between 55 and 100 MHz. The Pulse Intensity Integral (PII), used to calculate the Thermal Index (TI), was found to increase with increasing bandwidth and decreasing effective aperture of the probes. The Mechanical Index (MI), another safety indicator, was also affected, but to a lesser extent. The corrections needed were predicted using the model and successfully reduced the discrepancy as large as 30% in the determination of PII. The results of this work indicate that by accounting for hydrophones' finite aperture and correcting the value of PII, all intensities derived from the PII can be corrected for spatial averaging error. The results also point out that a caution should be exercised when comparing acoustic output data. In particular, hydrophone's frequency characteristics of the effective diameter and sensitivity are needed to correctly determine the MI, TI, and the total acoustic output power produced by an imaging transducer.


Subject(s)
Acoustics/instrumentation , Ultrasonics , Calibration , Equipment Design , Transducers
17.
Ultrasonics ; 41(8): 615-21, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14585473

ABSTRACT

This paper describes a novel approach to estimate broadband ultrasound attenuation (BUA) in a bone structure in human in vivo using coded excitation. BUA is an accepted indicator for assessment of osteoporosis. In the tested approach a coded acoustic signal is emitted and then the received echoes are compressed into brief, high amplitude pulses making use of matched filters and correlation receivers. In this way the acoustic peak pressure amplitude probing the tissue can be markedly decreased whereas the average transmitted intensity increases proportionally to the length of the code. This paper examines the properties of three different transmission schemes, based on Barker code, chirp and Golay code. The system designed is capable of generating 16 bits complementary Golay code (CGC), linear frequency modulated (LFM) chirp and 13-bit Barker code (BC) at 0.5 and 1 MHz center frequencies. Both in vivo data acquired from healthy heel bones and in vitro data obtained from human calcaneus were examined and the comparison between the results using coded excitation and two cycles sine burst is presented. It is shown that CGC system allows the effective range of frequencies employed in the measurement of broadband acoustic energy attenuation in the trabecular bone to be doubled in comparison to the standard 0.5 MHz pulse transmission. The algorithm used to calculate the pairs of Golay sequences of the different length, which provide the temporal side-lobe cancellation is also presented. Current efforts are focused on adapting the system developed for operation in pulse-echo mode; this would allow examination and diagnosis of bones with limited access such as hip bone.


Subject(s)
Calcaneus/diagnostic imaging , Osteoporosis/diagnostic imaging , Acoustics , Algorithms , Humans , Mass Screening , Ultrasonography/methods
18.
Ultrasonics ; 41(8): 635-41, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14585475

ABSTRACT

The spatial averaging effect is strongly dependent on the active aperture of the hydrophone probes used to measure ultrasound fields. An experimental method was developed to determine the effective diameter of the probes as a quasi-continuous function of frequency. The implementation of the method utilizes the time delay spectrometry (TDS) technique and a set of focused acoustic sources. The use of focused sources ensured plane wave conditions for the whole frequency range and TDS eliminated all the reflections from the water tank boundaries. This approach allows effective diameter of circular aperture hydrophones to be determined as a quasi-continuous function of frequency up to 40 MHz. The measurements were performed for both needles and membrane designs having nominal diameters ranging from 50 to 500 microm. The results were successfully employed in the development of spatial averaging correction algorithms. Current efforts are being focused on extension of the frequency range up to 60 MHz by using a novel measurement technique termed time gating frequency analysis.


Subject(s)
Acoustics/instrumentation , Ultrasonics , Algorithms , Transducers , Water
19.
Am J Med Genet A ; 121A(3): 209-13, 2003 Sep 01.
Article in English | MEDLINE | ID: mdl-12923859

ABSTRACT

Hyperechogenic fetal bowel is detected in 0.1-1.8% of pregnancies during the second or third trimester. This ultrasound sign is associated with cystic fibrosis or other conditions (e.g., chromosomal anomalies, viral infection) but no large-scale prospective studies have been conducted. This 1997-1998 multicenter study in 22 molecular biology laboratories identified 682 cases of hyperechogenic fetal bowel detected by routine ultrasound examination during the second (86%) or third trimester. The fetal bowel was considered hyperechogenic when its echogenicity was broadly similar to, or greater than, that of the surrounding bone. Karyotyping, screening for viral infection, and screening for cystic fibrosis mutations were performed in all cases. Pregnancy outcome and postnatal follow-up were obtained in 656 of the 682 cases (91%). In 447 cases (65.5%), a normal birth was observed. Multiple malformations were observed in 47 cases (6.9%), a significant chromosomal anomaly was noted in 24 (3.5%), cystic fibrosis in 20 (3%), and viral infection in 19 (2.8%). In utero unexplained fetal death occurred in 1.9% of cases, toxemia in 1.2%, IUGR in 4.1%, and premature birth in 6.2%. This study demonstrates that this ultrasound sign is potentially associated with medically significant outcomes. Having established that the bowel is hyperechogenic, recommended investigations should include a detailed scan with Doppler measurements, fetal karyotyping, cystic fibrosis screening, and infectious disease screening. After birth, newborns require pediatric examination because a surgical treatment may be necessary. This should be combined with clear counseling of the parents.


Subject(s)
Fetal Diseases/diagnostic imaging , Gastrointestinal Diseases/diagnostic imaging , Gastrointestinal Tract/abnormalities , Gastrointestinal Tract/embryology , Ultrasonography, Prenatal , Chromosome Aberrations , Cystic Fibrosis/diagnosis , Cystic Fibrosis/genetics , Cystic Fibrosis Transmembrane Conductance Regulator/genetics , Female , Fetal Growth Retardation , Gastrointestinal Tract/diagnostic imaging , Humans , Infant, Newborn , Karyotyping , Phenotype , Predictive Value of Tests , Pregnancy , Pregnancy Outcome , Pregnancy Trimester, Second , Prognosis , Prospective Studies , Risk Factors
20.
Ultrasonics ; 41(4): 247-54, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12782255

ABSTRACT

A number of ultrasound imaging systems employs harmonic imaging to optimize the trade off between resolution and penetration depth and center frequencies as high as 15 MHz are now used in clinical practice. However, currently available measurement tools are not fully adequate to characterize the acoustic output of such nonlinear systems primarily due to the limited knowledge of the frequency responses beyond 20 MHz of the available piezoelectric hydrophone probes. In addition, ultrasound hydrophone probes need to be calibrated to eight times the center frequency of the imaging transducer. Time delay spectrometry (TDS) is capable of providing transduction factor of the probes beyond 20 MHz, however its use is in practice limited to 40 MHz. This paper describes a novel approach termed time gating frequency analysis (TGFA) that provides the transduction factor of the hydrophone probes in the frequency domain and significantly extends the quasi-continuous calibration of the probes up to 60 MHz. The verification of the TGFA data was performed using TDS calibration technique (up to 40 MHz) and a nonlinear calibration method (up to 100 MHz). The nonlinear technique was based on a novel wave propagation model capable of predicting the true pressure-time waveforms at virtually any point in the field. The spatial averaging effects introduced by the finite aperture hydrophones were also accounted for. TGFA calibration results were obtained for different PVDF probes, including needle and membrane designs with nominal diameters from 50 to 500 micro m. The results were compared with discrete calibration data obtained from an independent national laboratory and the overall uncertainty was determined to be +/-1.5 dB in the frequency range 40-60 MHz and less than +/-1 dB below 40 MHz.


Subject(s)
Acoustics/instrumentation , Ultrasonics , Calibration , Equipment Design , Transducers
SELECTION OF CITATIONS
SEARCH DETAIL
...