Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Angew Chem Int Ed Engl ; 63(7): e202318026, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38157447

ABSTRACT

The study of facile-synthesis and low-cost X-ray scintillators with high light yield, low detection limit and high X-ray imaging resolution plays a vital role in medical and industrial imaging fields. However, the optimal balance between X-ray absorption, decay lifetime and excitonic utilization efficiency of scintillators to achieve high-resolution imaging is extremely difficult due to the inherent contradiction. Here two thermally activated delayed fluorescence (TADF)-actived coinage-metal clusters M6 S6 L6 (M=Ag or Cu) were synthesized by simple solvothermal reaction, where the cooperation of heavy atom-rich character and TADF mechanism supports strong X-ray absorption and rapid luminescent collection of excitons. Excitingly, Ag6 S6 L6 (SC-Ag) displays a high photoluminescence quantum yield of 91.6 % and scintillating light yield of 17420 photons MeV-1 , as well as a low detection limit of 208.65 nGy s-1 that is 26 times lower than the medical standard (5.5 µGy s-1 ). More importantly, a high X-ray imaging resolution of 16 lp/mm based on SC-Ag screen is demonstrated. Besides, rigid core skeleton reinforced by metallophilicity endows clusters M6 S6 L6 strong resistance to humidity and radiation. This work provides a new view for the design of efficient scintillators and opens the research door for silver clusters in scintillation application.

2.
Small ; 19(42): e2302492, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37154205

ABSTRACT

Anisotropic charge transport plays a pivotal role in clarifying the conductivity mechanism in direct X-ray detection to improve the detection sensitivity. However, the anisotropic photoelectric effect of semiconductive single crystal responsive to X-ray is still lacking of theoretical and experimental proof. The semiconductive coordination polymers (CPs) with designable structures, adjustable functions, and high crystallinity provide a suitable platform for exploring the anisotropic conductive mechanism. Here,the study first reveals a 1D conductive transmission path for direct X-ray detection from the perspective of structural chemistry. The semiconductive copper(II)-based CP 1 single crystal detector exhibits unique anisotropic X-ray detection performance. Along the 1D π-π stacking direction, the single crystal device (1-SC-a) shows a superior sensitivity of 2697.15 µCGyair -1  cm-2 and a low detection limit of 1.02 µGyair  s-1 among CPs-based X-ray detectors. This study provides beneficial guidance and deep insight for designing high-performance CP-based X-ray detectors.

3.
Nano Lett ; 23(10): 4351-4358, 2023 May 24.
Article in English | MEDLINE | ID: mdl-37156492

ABSTRACT

Luminescent metal halides have been exploited as a new class of X-ray scintillators for security checks, nondestructive inspection, and medical imaging. However, the charge traps and hydrolysis vulnerability are always detrimental to the three-dimensional ionic structural scintillators. Here, the two zero-dimensional organic-manganese(II) halide coordination complexes 1-Cl and 2-Br were synthesized for improvements in X-ray scintillation. The introduction of a polarized phosphine oxide can help to increase the stabilities, especially the self-absorption-free merits of these Mn-based hybrids. The X-ray dosage rate detection limits reached up to 3.90 and 0.81 µGyair/s for 1-Cl and 2-Br, respectively, superior to the medical diagnostic standard of 5.50 µGyair/s. The fabricated scintillation films were applied to radioactive imaging with high spatial resolutions of 8.0 and 10.0 lp/mm, respectively, holding promise for use in diagnostic X-ray medical imaging.

4.
Inorg Chem ; 61(24): 8982-8986, 2022 Jun 20.
Article in English | MEDLINE | ID: mdl-35658461

ABSTRACT

Two examples of efficient cathode-ray scintillation coordination polymers with good stability at high voltage were prepared by conjugating luminescent groups with d10 metal ions. The synergistic effect of inorganic metal and organic ligand suppresses the self-quenching of the conjugated luminescent groups and enhances the scintillation performance. This work provides new ideas for the design of new field-emission displays and cathode-ray scintillation materials.

SELECTION OF CITATIONS
SEARCH DETAIL
...