Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
IET Syst Biol ; 9(6): 285-93, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26577163

ABSTRACT

In the field of systems biology, biological reaction networks are usually modelled by ordinary differential equations. A sub-class, the S-systems representation, is a widely used form of modelling. Existing S-systems identification techniques assume that the system itself is always structurally identifiable. However, due to practical limitations, biological reaction networks are often only partially measured. In addition, the captured data only covers a limited trajectory, therefore data can only be considered as a local snapshot of the system responses with respect to the complete set of state trajectories over the entire state space. Hence the estimated model can only reflect partial system dynamics and may not be unique. To improve the identification quality, the structural and practical identifiablility of S-system are studied. The S-system is shown to be identifiable under a set of assumptions. Then, an application on yeast fermentation pathway was conducted. Two case studies were chosen; where the first case is based on a larger state trajectories and the second case is based on a smaller one. By expanding the dataset which span a relatively larger state space, the uncertainty of the estimated system can be reduced. The results indicated that initial concentration is related to the practical identifiablity.


Subject(s)
Models, Biological , Systems Biology/methods
2.
Sensors (Basel) ; 14(2): 2397-416, 2014 Jan 30.
Article in English | MEDLINE | ID: mdl-24487623

ABSTRACT

This paper presents a ZigBee In-Patient Monitoring system embedded with a new ZigBee mobility management solution. The system enables ZigBee device mobility in a fixed ZigBee network. The usage, the architecture and the mobility framework are discussed in details in the paper. The evaluation shows that the new algorithm offers a good efficiency, resulting in a low management cost. In addition, the system can save lives by providing a panic button and can be used as a location tracking service. A case study focused on the Princes of Wales Hospital in Hong Kong is presented and findings are given. This investigation reveals that the developed mobile solutions offer promising value-added services for many potential ZigBee applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...