Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
Add more filters










Publication year range
1.
Biosens Bioelectron ; 258: 116353, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38696966

ABSTRACT

Male infertility is a pervasive global reproductive challenge, primarily attributed to a decline in semen quality. Addressing this concern, there has been a growing focus on spermatozoa sorting in assisted reproductive technology. This study introduces a groundbreaking development in the form of a thermotaxis and rheotaxis microfluidic (TRMC) device designed for efficient motile spermatozoa sorting within a short 15-min timeframe. The TRMC device mimics the natural sperm sorting mechanism of the oviduct, selecting spermatozoa with superior motility and DNA integrity. The experimental outcomes demonstrate a remarkable enhancement in the percentage of progressive spermatozoa following sorting, soaring from 3.90% to an impressive 96.11% when subjected to a temperature decrease from 38 °C to 35 °C. Notably, sperm motility exhibited a substantial 69% improvement. The TRMC device exhibited a commendable recovery rate of 60.93%, surpassing current clinical requirements. Furthermore, the sorted spermatozoa displayed a notable reduction in the DNA fragmentation index to 6.94%, signifying a substantial 90% enhancement in DNA integrity. This remarkable advancement positions the TRMC device as highly suitable for applications in in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI), offering a promising solution to male infertility challenges.


Subject(s)
Lab-On-A-Chip Devices , Sperm Motility , Spermatozoa , Male , Spermatozoa/physiology , Spermatozoa/cytology , Humans , Equipment Design , Infertility, Male , Biosensing Techniques/instrumentation , Cell Separation/instrumentation , DNA Fragmentation , Temperature
2.
Adv Mater ; 36(6): e2307743, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37988595

ABSTRACT

All-perovskite tandem solar cells show great potential to enable the highest performance at reasonable costs for a viable market entry in the near future. In particular, wide-bandgap (WBG) perovskites with higher open-circuit voltage (VOC ) are essential to further improve the tandem solar cells' performance. Here, a new 1.8 eV bandgap triple-halide perovskite composition in conjunction with a piperazinium iodide (PI) surface treatment is developed. With structural analysis, it is found that the PI modifies the surface through a reduction of excess lead iodide in the perovskite and additionally penetrates the bulk. Constant light-induced magneto-transport measurements are applied to separately resolve charge carrier properties of electrons and holes. These measurements reveal a reduced deep trap state density, and improved steady-state carrier lifetime (factor 2.6) and diffusion lengths (factor 1.6). As a result, WBG PSCs achieve 1.36 V VOC , reaching 90% of the radiative limit. Combined with a 1.26 eV narrow bandgap (NBG) perovskite with a rubidium iodide additive, this enables a tandem cell with a certified scan efficiency of 27.5%.

3.
Biomacromolecules ; 24(11): 5467-5477, 2023 11 13.
Article in English | MEDLINE | ID: mdl-37862241

ABSTRACT

Biofouling due to nonspecific proteins or cells on the material surfaces is a major challenge in a range of applications such as biosensors, medical devices, and implants. Even though poly(ethylene glycol) (PEG) has become the most widely used stealth material in medical and pharmaceutical products, the number of reported cases of PEG-triggered rare allergic responses continues to increase in the past decades. Herein, a new type of antifouling material poly(amine oxide) (PAO) has been evaluated as an alternative to overcome nonspecific foulant adsorption and impart comparable biocompatibility. Alkyl-substituted PAO containing diethyl, dibutyl, and dihexyl substituents are prepared, and their solution properties are studied. Photoreactive copolymers containing benzophenone as the photo-cross-linker are prepared by reversible addition-fragmentation chain-transfer polymerization and fully characterized by gel permeation chromatography and dynamic light scattering. Then, these water-soluble polymers are anchored onto a silicon wafer with the aid of UV irradiation. By evaluating the fouling resistance properties of these modified surfaces against various types of foulants, protein adsorption and bacterial attachment assays show that the cross-linked PAO-modified surface can efficiently inhibit biofouling. Furthermore, human blood cell adhesion experiments demonstrate that our PAO polymer could be used as a novel surface modifier for biomedical devices.


Subject(s)
Biofouling , Polymers , Humans , Polymers/pharmacology , Polymers/chemistry , Biofouling/prevention & control , Oxides , Amines , Polyethylene Glycols/chemistry , Surface Properties , Adsorption
4.
iScience ; 26(8): 107356, 2023 Aug 18.
Article in English | MEDLINE | ID: mdl-37559897

ABSTRACT

Assisted reproductive technology (ART) is an important invention for the treatment of human infertility, and the isolation of high-quality sperm with progressive motility is one of the most critical steps that eventually affect the fertilization rate. Conventional sperm separation approaches include the swim-up method and density gradient centrifugation. However, the quality of isolated sperm obtained from both approaches can still be improved by improving sorted sperm motility, minimizing the DNA fragmentation rate, and removing abnormal phenotypes. Here, we report a Progressive Sperm Sorting Chip (PSSC) for high-quality sperm isolation. Based on the rheotaxis behavior of sperm, a gradient flow field is created in the chip for progressive sperm sorting. Clinical experiment results for 10 volunteers showed that greater than 90% of isolated sperm exhibit high motility (> 25 µm/s), high linearity (0.8), and a very low DNA fragmentation rate (< 5%). In addition, the whole process is label and chemical free. These features aid in gentle sperm sorting to obtain healthy sperm. This device uniquely enables the selection of high-quality sperm with progressive motility and might be clinically applied for infertility treatment in the near future.

5.
Science ; 381(6653): 63-69, 2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37410849

ABSTRACT

Improved stability and efficiency of two-terminal monolithic perovskite-silicon tandem solar cells will require reductions in recombination losses. By combining a triple-halide perovskite (1.68 electron volt bandgap) with a piperazinium iodide interfacial modification, we improved the band alignment, reduced nonradiative recombination losses, and enhanced charge extraction at the electron-selective contact. Solar cells showed open-circuit voltages of up to 1.28 volts in p-i-n single junctions and 2.00 volts in perovskite-silicon tandem solar cells. The tandem cells achieve certified power conversion efficiencies of up to 32.5%.

6.
Biosens Bioelectron ; 236: 115403, 2023 Sep 15.
Article in English | MEDLINE | ID: mdl-37271096

ABSTRACT

Water is one of the most indispensable elements for human beings. People can live without food for a couple of weeks but cannot live without water for a couple of days. Unfortunately, drinking water is not always safe around the world; in many areas, the water for drinking could be contaminated with various microbes. However, the total viable microbe count in water still relies on culture-based methods in laboratories. Therefore, in this work, we report a novel, simple, and highly efficient strategy to detect live bacteria in water via a nylon membrane-integrated centrifugal microfluidic device. A handheld fan and a rechargeable hand warmer were utilized as the centrifugal rotor and the heat resource for reactions, respectively. The bacteria in water can be rapidly concentrated >500-fold by our centrifugation system. After incubation with water-soluble tetrazolium-8 (WST-8), the color change of the nylon membranes can be visually interpreted directly by the naked eye or recorded with a smartphone camera. The whole process can be finished in 3 h, and the detection limit can reach 102 CFU/mL. The detection range ranges from 102 CFU/mL to 105 CFU/mL. The cell counting results of our platform are highly positively correlated with the results of cell counting by the conventional lysogeny broth (LB) agar plate approach or the commercial 3 M Petrifilm™ cell counting plate. Our platform provides a convenient and sensitive strategy for rapid monitoring. We highly anticipate that this platform can improve water quality monitoring in resource-poor countries in the near future.


Subject(s)
Biosensing Techniques , Microfluidics , Humans , Nylons , Bacteria , Smartphone
7.
Nat Commun ; 14(1): 3797, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-37365175

ABSTRACT

Achieving high solar-to-hydrogen (STH) efficiency concomitant with long-term durability using low-cost, scalable photo-absorbers is a long-standing challenge. Here we report the design and fabrication of a conductive adhesive-barrier (CAB) that translates >99% of photoelectric power to chemical reactions. The CAB enables halide perovskite-based photoelectrochemical cells with two different architectures that exhibit record STH efficiencies. The first, a co-planar photocathode-photoanode architecture, achieved an STH efficiency of 13.4% and 16.3 h to t60, solely limited by the hygroscopic hole transport layer in the n-i-p device. The second was formed using a monolithic stacked silicon-perovskite tandem, with a peak STH efficiency of 20.8% and 102 h of continuous operation before t60 under AM 1.5G illumination. These advances will lead to efficient, durable, and low-cost solar-driven water-splitting technology with multifunctional barriers.

8.
Annu Rev Anal Chem (Palo Alto Calif) ; 16(1): 181-203, 2023 06 14.
Article in English | MEDLINE | ID: mdl-36888989

ABSTRACT

The development of wearable devices provides approaches for the realization of self-health care. Easily carried wearable devices allow individual health monitoring at any place whenever necessary. There are various interesting monitoring targets, including body motion, organ pressure, and biomarkers. An efficient use of space in one small device is a promising resolution to increase the functions of wearable devices. Through integration of a microfluidic system into wearable devices, embedding complicated structures in one design becomes possible and can enable multifunction analyses within a limited device volume. This article reviews the reported microfluidic wearable devices, introduces applications to different biofluids, discusses characteristics of the design strategies and sensing principles, and highlights the attractive configurations of each device. This review seeks to provide a detailed summary of recent advanced microfluidic wearable devices. The overview of advanced key components is the basis for the development of future microfluidic wearable devices.


Subject(s)
Microfluidics , Wearable Electronic Devices , Humans , Biological Assay , Motion , Self Care
9.
Langmuir ; 39(5): 1897-1904, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36696912

ABSTRACT

Urinalysis is one of the simplest and most common medical tests in modern cities. With the assistance of professional technicians and equipment, people in metropolitan areas can effortlessly acquire information about their physiological conditions from traditional clinical laboratories. However, the threshold, including precise benchtop equipment and well-trained personnel, still remains a considerable dilemma for residents in healthcare-poor areas. Hence, it is a crucial and urgent topic to develop a smart and affordable widget to address this challenge. To improve the healthcare rights of residents, we proposed a disposable centrifugal microfluidic urine routine examination platform (named µCUREX) actuated with a modified hand-powered fan. Two parts of urinalysis (sediment test and chemical strip test) were integrated into the µCUREX disc. The influence on sedimentation by variant hand-powered manipulation was simulated using COMSOL. As a result, more than 70% of the sediment can be collected. Moreover, the color change of chemical strip papers (indicators for glucose, pH, protein, and occult blood) was recorded with a 3D-printed studio and analyzed after reaction with chemical-spiked and pH-adjusted artificial and human urine specimens. The whole process can be completed within 10 min, with only 200 µL of urine needed. In conclusion, we successfully constructed an ultra-low-cost point-of-care platform for urinalysis in extremely resource-poor settings. The handy size, high affordability, and user-friendliness of the µCUREX disc provide strong potential and feasibility in solving problems in resource-poor settings. Furthermore, we highly expect the µCUREX platform to improve the level of healthcare in resource-limited areas.


Subject(s)
Microfluidics , Point-of-Care Systems , Humans , Urinalysis , Glucose , Proteins
10.
Talanta ; 254: 124154, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36527913

ABSTRACT

Alzheimer's disease (AD) is one of the important neurodegenerative diseases, in the modern aging society, it has become an issue people need to work on. Of the pathogenic factor which leads to AD, beta-amyloid (Aß) is the most important one. It can form the senile plaque which aggregates in the neuron and interrupts the signal transmission. This research is based on the electrochemical system and screen-printed carbon electrode (SPCE) incorporated with pretreatment, electrodeposition, electrochemical impedance spectroscopy (EIS), antibody, and blocking agent. This immunosensor is applied to detect the different concentrations of Aß. The standard curve between electrical impedance and concentration of Aß is calculated. The specificity of the immunosensor is tested. This survey optimizes the electrodeposition condition for 4-aminobenzoic acid (4-ABA) and the parameter for antibody and blocking agents. This study fabricates a more dense, uniform, and stable film of 4-ABA. This sensor presents a range of detection from 1 fg/ml to 100 pg/ml and a limit of detection to 3.84 fg/ml. This sensor can identify the isoform of Aß. This research shortens the fabricating time to 3.5 h. This study fabricates a label-free and low-cost immunosensor for Aß with a short fabricating time, high stability, wide range of detection, low limit of detection, and good specificity. The impedance of the carbon printed electrodes is very high and is always measured by its current but this study provides a fabrication technique for high-efficiency carbon printed electrodes for electrochemical impedance spectroscopy sensing.


Subject(s)
Biosensing Techniques , Carbon , 4-Aminobenzoic Acid , Amyloid beta-Peptides , Antibodies , Biosensing Techniques/methods , Carbon/chemistry , Dielectric Spectroscopy , Electrochemical Techniques , Electrodes , Gold/chemistry , Immunoassay , Limit of Detection
11.
Nat Nanotechnol ; 17(11): 1214-1221, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36280763

ABSTRACT

Perovskite-silicon tandem solar cells offer the possibility of overcoming the power conversion efficiency limit of conventional silicon solar cells. Various textured tandem devices have been presented aiming at improved optical performance, but optimizing film growth on surface-textured wafers remains challenging. Here we present perovskite-silicon tandem solar cells with periodic nanotextures that offer various advantages without compromising the material quality of solution-processed perovskite layers. We show a reduction in reflection losses in comparison to planar tandems, with the new devices being less sensitive to deviations from optimum layer thicknesses. The nanotextures also enable a greatly increased fabrication yield from 50% to 95%. Moreover, the open-circuit voltage is improved by 15 mV due to the enhanced optoelectronic properties of the perovskite top cell. Our optically advanced rear reflector with a dielectric buffer layer results in reduced parasitic absorption at near-infrared wavelengths. As a result, we demonstrate a certified power conversion efficiency of 29.80%.

12.
Talanta ; 241: 123187, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35030501

ABSTRACT

Recent advances in microelectronics and electrochemical sensing platforms have preceded the development of devices for personal monitoring and managing physiological and metabolic information that exploit sweat as a noninvasive, convenient approach for providing information about underlying health conditions, such as glucose level monitoring. Although most sweat glucose sensors have targeted applications during exercise and other active stimulation induced-sweat, natural sweating offers an attractive alternative with minimal effect on users that can be accessed during routine and sedentary activities without impeding personal lifestyle and preserves the correlation between blood and sweat glucose. Here, we present a noninvasive sweat glucose sensor with convenient hydrogel patches for rapid sampling of natural perspiration without external activities that stimulate sweating. The wearable hydrogel patch rapidly takes up natural sweat from the hand and serves as a medium for electrochemical sensing. A prussian blue-doped poly(3,4-ethylenedioxythiophene nanocomposite (PB-PEDOT NC) electrode provides cost-effective, stable and excellent electrocatalytic activity in sweat glucose measurements. We demonstrated sweat glucose sensor functionality by long-term measurements of glucose in sweat from human subjects consuming food and drinks. By enabling the analysis of sweat glucose during routine and sedentary activities, the sweat glucose sensor shows great promise for clinical-grade glucose management and enlarges the scope of next-generation noninvasive sensing systems.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Glucose , Humans , Hydrogels , Sweat , Sweating
13.
Sci Rep ; 11(1): 21019, 2021 10 25.
Article in English | MEDLINE | ID: mdl-34697372

ABSTRACT

Since nucleic acid amplification technology has become a vital tool for disease diagnosis, the development of precise applied nucleic acid detection technologies in point-of care testing (POCT) has become more significant. The microfluidic-based nucleic acid detection platform offers a great opportunity for on-site diagnosis efficiency, and the system is aimed at user-friendly access. Herein, we demonstrate a microfluidic system with simple operation that provides reliable nucleic acid results from 18 uniform droplets via LAMP detection. By using only micropipette regulation, users are able to control the nanoliter scale of the droplets in this valve-free and pump-free microfluidic (MF) chip. Based on the oil enclosure method and impermeable fabrication, we successfully preserved the reagent inside the microfluidic system, which significantly reduced the fluid loss and condensation. The relative standard deviation (RSD) of the fluorescence intensity between the droplets and during the heating process was < 5% and 2.0%, respectively. Additionally, for different nucleic acid detection methods, the MF-LAMP chip in this study showed good applicability to both genome detection and gene expression analysis.

14.
Sci Rep ; 11(1): 14915, 2021 07 21.
Article in English | MEDLINE | ID: mdl-34290353

ABSTRACT

Droplet-based transport driven by surface tension has been explored as an automated pumping source for several biomedical applications. This paper presented a simple and fast superhydrophobic modify and patterning approach to fabricate various open-surface platforms to manipulate droplets to achieve transport, mixing, concentration, and rebounding control. Several commercial reagents were tested in our approach, and the Glaco reagent was selected to create a superhydrophobic layer; laser cutters are utilized to scan on these superhydrophobic surface to create gradient hydrophilic micro-patterns. Implementing back-and-forth vibrations on the predetermined parallel patterns, droplets can be transported and mixed successfully. Colorimetry of horseradish peroxidase (HRP) mixing with substrates also reduced the reaction time by more than 5-times with the help of superhydrophobic patterned chips. Besides, patterned superhydrophobic chips can significantly improve the sensitivity of colorimetric glucose-sensing by more than 10 times. Moreover, all bioassays were distributed homogeneously within the region of hydrophilic micropatterns without the coffee-ring effect. In addition, to discuss further applications of the surface wettability, the way of controlling the droplet impacting and rebounding phenomenon was also demonstrated. This work reports a rapid approach to modify and patterning superhydrophobic films to perform droplet-based manipulations with a lower technical barrier, higher efficiency, and easier operation. It holds the potential to broaden the applications of open microfluidics in the future.

15.
ACS Appl Mater Interfaces ; 13(11): 13022-13033, 2021 Mar 24.
Article in English | MEDLINE | ID: mdl-33721995

ABSTRACT

Through the optimization of the perovskite precursor composition and interfaces to selective contacts, we achieved a p-i-n-type perovskite solar cell (PSC) with a 22.3% power conversion efficiency (PCE). This is a new performance record for a PSC with an absorber bandgap of 1.63 eV. We demonstrate that the high device performance originates from a synergy between (1) an improved perovskite absorber quality when introducing formamidinium chloride (FACl) as an additive in the "triple cation" Cs0.05FA0.79MA0.16PbBr0.51I2.49 (Cs-MAFA) perovskite precursor ink, (2) an increased open-circuit voltage, VOC, due to reduced recombination losses when using a lithium fluoride (LiF) interfacial buffer layer, and (3) high-quality hole-selective contacts with a self-assembled monolayer (SAM) of [2-(9H-carbazol-9-yl)ethyl]phosphonic acid (2PACz) on ITO electrodes. While all devices exhibit a high performance after fabrication, as determined from current-density voltage, J-V, measurements, substantial differences in device performance become apparent when considering longer-term stability data. A reduced long-term stability of devices with the introduction of a LiF interlayer is compensated for by using FACl as an additive in the metal-halide perovskite thin-film deposition. Optimized devices maintained about 80% of the initial average PCE during maximum power point (MPP) tracking for >700 h. We scaled the optimized device architecture to larger areas and achieved fully laser patterned series-interconnected mini-modules with a PCE of 19.4% for a 2.2 cm2 active area. A robust device architecture and reproducible deposition methods are fundamental for high performance and stable large-area single junction and tandem modules based on PSCs.

16.
RSC Adv ; 11(46): 28551-28556, 2021 Aug 23.
Article in English | MEDLINE | ID: mdl-35478579

ABSTRACT

Enzyme-linked immunosorbent assays (ELISAs) are tests that uses antibody recognition and enzyme catalytic activity to identify a substance, and they have been widely used as a diagnostic tool in the clinic. However, performing an ELISA requires various liquid handling steps and long binding times. To solve this problem, we developed a magnetic microfluidic ELISA system (MMF-ELISA). Integration with nickel magnetic nanoparticles can streamline the ELISA process in a fully automated manner for Streptococcus pneumoniae detection. First, we synthesized paramagnetic surface-oxidized nickel nanoparticles (Ni/NiO NPs) to carry protein G. Then, we assembled a SUM290 (UlaG)-specific antibody on protein G. Finally, we integrated the NPs on a microfluidics chip for S. pneumoniae detection. The chip contains three different layers to trap the solutions; the bottom layer SiO2 is patterned on hydrophobic polymers and integrated with the middle layer PDMS and the top layer PMMA. With Arduino and motor IC, we developed an automated platform for S. pneumoniae detection. Microfluidic ELISAs can reduce the manual handling and operation time. Furthermore, the developed system can be extended to multiple areas for ELISA-related assays. This economical, rapid and portable system may become a promising platform for sensing S. pneumoniae in clinical applications.

17.
Science ; 370(6522): 1300-1309, 2020 12 11.
Article in English | MEDLINE | ID: mdl-33303611

ABSTRACT

Tandem solar cells that pair silicon with a metal halide perovskite are a promising option for surpassing the single-cell efficiency limit. We report a monolithic perovskite/silicon tandem with a certified power conversion efficiency of 29.15%. The perovskite absorber, with a bandgap of 1.68 electron volts, remained phase-stable under illumination through a combination of fast hole extraction and minimized nonradiative recombination at the hole-selective interface. These features were made possible by a self-assembled, methyl-substituted carbazole monolayer as the hole-selective layer in the perovskite cell. The accelerated hole extraction was linked to a low ideality factor of 1.26 and single-junction fill factors of up to 84%, while enabling a tandem open-circuit voltage of as high as 1.92 volts. In air, without encapsulation, a tandem retained 95% of its initial efficiency after 300 hours of operation.

18.
iScience ; 23(11): 101658, 2020 Nov 20.
Article in English | MEDLINE | ID: mdl-33117969

ABSTRACT

Sweat-based wearable devices have attracted increasing attention by providing abundant physiological information and continuous measurement through noninvasive healthcare monitoring. Sweat pressure generated via sweat glands to the skin surface associated with osmotic effects may help to elucidate such parameters as physiological conditions and psychological factors. This study introduces a wearable device for measuring secretion sweat pressure through noninvasive, continuous monitoring. Secretion pressure is detected by a microfluidic chip that shows the resistance variance from a paired electrode pattern and transfers digital signals to a smartphone for real-time display. A human study demonstrates this measurement with different exercise activities, showing the pressure ranges from 1.3 to 2.5 kPa. This device is user-friendly and applicable to exercise training and personal health care. The convenience and easy-to-wear characteristics of this device may establish a foundation for future research investigating sweat physiology and personal health care.

19.
Lab Chip ; 20(21): 4007-4015, 2020 11 07.
Article in English | MEDLINE | ID: mdl-32966477

ABSTRACT

Lung cancer is one of the leading causes of death worldwide. Fifteen percent of lung cancer patients will present with malignant pleural effusion initially, and up to 50% will have malignant pleural effusion throughout the course of the disease. In this study, we developed a spiral microfluidic device that can rapidly isolate cancer cells and improve their purity through fluid dynamics. This label-free, high-throughput device continuously isolates cancer cells and other unrelated molecules from pleural effusion. Most of the background cells that affect interpretation are flushed to outlets 1 to 3, and cancer cells are hydrodynamically concentrated to outlet 4, with 90% of lung cancer cells flowing to this outlet. After processing, the purity of cancer cells identified in pleural effusion by CD45 and epithelial cell adhesion molecule (EpCAM) antibodies in flow cytometry will be increased by 6 to 24 times. The microfluidic device presented here has the advantages of rapid processing and low cost, which are conducive to rapid and accurate clinical diagnosis.


Subject(s)
Lung Neoplasms , Pleural Effusion, Malignant , Pleural Effusion , Flow Cytometry , Humans , Lung Neoplasms/diagnosis , Microfluidics , Pleural Effusion/diagnosis , Pleural Effusion, Malignant/diagnosis
20.
Analyst ; 145(4): 1110-1120, 2020 Feb 17.
Article in English | MEDLINE | ID: mdl-31916551

ABSTRACT

Electrochemical biosensors have been applied in a broad range of clinical applications for pathogen biomarker detection and medical applications and diagnosis due to the sensitivity of electrochemical methods and the bioselectivity of the components. The complexity of clinical conditions with various biofoulants (proteins, cells, polysaccharides and lipids) severely influences the reliability and stability of sensors for direct detection or immersion under changing conditions. Therefore, designing an antifouling sensing platform that can effectively reduce undesired binding to maintain biosensor performance in optimized analysis is necessary. For this purpose, the fundamental mechanisms of fouling materials and commonly used biocompatible antifouling components have been discussed, and the relevant effective modification strategies are introduced in this review. Recent advances in these strategies are demonstrated in examples with analysis of essential modification methods for reliable sensing in non-specific binding solutions or complex biofluids. The challenges and future perspectives of modification strategies for current clinical application are also discussed in this review.


Subject(s)
Biofouling/prevention & control , Biosensing Techniques/methods , Electrochemistry/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...