Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
2.
Surg Endosc ; 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38898340

ABSTRACT

BACKGROUND: Endoscopic ultrasound-guided pancreatic duct (PD) drainage (EUS-PDD) is being increasingly performed as an alternative method to surgical drainage to achieve PD decompression after failed endoscopic retrograde pancreatography (ERP). However, no directly study has compared EUS-PDD with surgical PD drainage after failed ERP in patients with chronic pancreatitis. METHODS: Consecutive patients who underwent EUS-PDD or longitudinal pancreaticojejunostomy after failed ERP were retrospectively identified from our endoscopy and medical information systems. The primary end point was the Izbicki pain score. The secondary end points were pain relief at the end of follow-up, procedure outcomes, adverse events, readmission, and reintervention. RESULTS: A total of 21 patients (11 EUS-PDD, 10 surgical drainages) were analyzed. There were no significant differences in mean Izbicki pain score (EUS-PDD, 13.6 ± 10.1 vs. surgical drainage 10.7 ± 7.9, p = 0.483) or complete/partial pain relief (60%/30% vs. 70%/30%, p = 0.752) at the end of follow-up of the two groups. The rates of overall adverse events (27.3% vs. 30.0%, p = 0.893) and readmission (63.6% vs. 40.0%, p = 0.290) were similar in the two treatment groups, while patients in EUS-PDD group required more reinterventions (45.5% vs. 0%, p = 0.039) compared with patients in the surgery group. CONCLUSION: EUS-PDD showed comparable pain relief and safety to surgical PD drainage after failed ERP, with a higher rate of reintervention. The selection of EUS-PDD or surgical drainage may be appropriate based on an individualized strategy.

5.
Article in English | MEDLINE | ID: mdl-38736198

ABSTRACT

BACKGROUND AND AIM: Several meta-analyses have analyzed the technical and clinical success of endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) by using lumen-apposing metal stents (LAMS) in malignant biliary obstruction, but those concerning adverse events (AEs) are scarce. The current systematic review and meta-analysis was conducted to evaluate the AEs after EUS-CDS with LAMS. METHODS: A comprehensive literature search of PubMed, Embase, Scopus, Web of Science, and the Cochrane Library was conducted for studies reporting the outcomes of EUS-CDS with LAMS. The main endpoints were the incidence of overall and specific AEs. Moreover, the stent dysfunction, and reintervention rates were evaluated independently. RESULTS: A total of 21 studies (n = 1438) were included in the final meta-analysis. The pooled rate of technical and clinical success was 93.5% (95% confidence interval [CI]: 91.3-95.1) and 88.0% (95% CI: 83.9-91.1), respectively. After EUS-CDS with LAMS, the pooled incidence of overall AEs was 20.1% (95% CI: 16.0-24.9). The estimated rate of early AEs was 10.6% (95% CI: 7.9-14.2), and late AEs was 11.2% (95% CI: 8.2-15.2). Infection/cholangitis was the commonest AE, with a pooled incidence of 6.1% (95% CI: 3.7-10.1). The estimated incidence of stent dysfunction and reintervention was 10.5% (95% CI: 7.5-14.4), and 12.1% (95% CI: 9.3-15.7), respectively. CONCLUSION: Despite with a high technical and clinical success rate, EUS-CDS with LAMS may be associated with overall AEs and stent dysfunction in one-fifth and one-tenth of cases, respectively. Further efforts are required to optimize its safety and long-term stent patency.

11.
Minim Invasive Ther Allied Technol ; 32(6): 285-299, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37310282

ABSTRACT

OBJECTIVE: A comprehensive meta-analysis was performed to evaluate the efficacy and safety of endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for benign and malignant gastric outlet obstruction (GOO). MATERIAL AND METHODS: PubMed, Embase, Web of Science and Cochrane Library were searched to identify relevant studies. The primary outcomes evaluated technical success, clinical success, and adverse events (AEs). RESULTS: Twenty­six studies with 1493 patients were included in this meta-analysis. The pooled rates of technical success, clinical success, and overall AEs of EUS-GE were 94.0%, 89.9%, and 13.1%, respectively. Eight studies were included in the subgroup meta-analysis for comparative evaluation of EUS-GE and surgical gastroenterostomy (SGE), while seven studies were for EUS-GE and enteral stenting (ES). Compared with SGE, the pooled odds ratios (ORs) of technical success, clinical success, and overall AEs of EUS-GE were 0.17 (p = .003), 1.42 (p = .40), and 0.15 (p < .00001), respectively. When compared with ES, the above corresponding pooled ORs were 0.55 (p = .11), 2.64 (p < .0001), and 0.41 (p = .01), respectively. CONCLUSION: Although it is technically challenging, this largest meta-analysis indicates that EUS­GE has comparable and high technical and clinical success rates and hence a very effective minimally invasive procedure for GOO.


Subject(s)
Gastric Outlet Obstruction , Gastroenterostomy , Humans , Gastroenterostomy/adverse effects , Gastroenterostomy/methods , Gastric Outlet Obstruction/etiology , Gastric Outlet Obstruction/surgery , Endosonography/methods , Stents , Retrospective Studies
16.
Surg Endosc ; 34(6): 2454-2459, 2020 06.
Article in English | MEDLINE | ID: mdl-31376008

ABSTRACT

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) for extraction of common bile duct (CBD) stones in Billroth II anatomy patients is still a technical challenge and factors affecting stone extraction have not yet been clarified. This study aimed to analyze our experience and evaluate potential factors affecting CBD stone extraction. METHODS: A retrospective analysis of CBD stones patients with a history of Billroth II gastrectomy, who underwent therapeutic ERCP for stone extraction at our center from August 1999 to December 2017, was conducted. The outcomes of ERCP and potential factors affecting stone extraction were examined. RESULTS: A total of 227 patients were enrolled, and 176 patients (77.5%) achieved technical success. The success rate of duodenal ampullary access and selective biliary cannulation was 84.1% (191/227) and 92.1% (176/191), respectively. The mean CBD diameter was 15 mm (range 6-35 mm), and the largest stone size was 13 mm (range 4-36 mm). CBD stones were ultimately removed in 137 patients (77.8%), and 105 patients (59.7%) for the first session. Mechanical lithotripsy was used in 17 patients (9.7%). The overall ERCP-related complication rate was 6.3% (11/176), including bleeding in 3 patients (1.7%) and mild pancreatitis in 6 patients (3.4%). The multivariate analysis indicated that CBD stone number ≥ 2 (OR 2.171; 95% CI 1.095-4.306; p = 0.027), and the largest CBD stone size ≥ 12 mm (OR 3.646; 95% CI 1.833-7.251; p < 0.001) were patient-related risk factors for failed stone removal; while the use of endoscopic papillary (large) balloon dilation (EPBD/EPLBD) (OR 0.291; 95% CI 0.147-0.576; p < 0.001) was a procedure-related protective factor for successful stone extraction. CONCLUSIONS: ERCP is safe and effective for extraction of CBD stones in Billroth II anatomy patients. The number and the largest size of CBD stones, and the use of EPBD/EPLBD are predictive factors for CBD stone extraction.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Common Bile Duct/surgery , Gallstones/surgery , Gastroenterostomy/methods , Adult , Aged , Aged, 80 and over , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Sphincterotomy, Endoscopic/adverse effects
18.
Saudi J Gastroenterol ; 25(6): 355-361, 2019.
Article in English | MEDLINE | ID: mdl-31187782

ABSTRACT

BACKGROUND/AIMS: Endoscopic retrograde cholangiopancreatography (ERCP) in Billroth II gastrectomy patients is technically demanding and factors affecting its technical difficulty have not yet been clarified. This study aimed to investigate the outcomes of ERCP in Billroth II gastrectomy patients and identify potential factors affecting its technical failure. PATIENTS AND METHODS: A large retrospective study of 308 consecutive patients (391 procedures) with Billroth II gastrectomy-who underwent ERCP from January 2002 to December 2016-was conducted. The outcomes of ERCP and potential factors affecting its technical failure were analyzed. RESULTS: The success rate of duodenal ampullary access, selective duct cannulation and the accomplishment of expected procedures was 81.3% (318/391), 86.5% (275/318) and 97.3% (256/263), respectively, and the technical success rate was 70.3% (275/391). The overall ERCP-related complication rate was 15.3% (60/391). The multivariate analysis indicated that first-time ERCP attempt [odds ratio (OR) 4.29, 95% confidence interval (CI) 2.34-7.85, P < 0.001], Braun anastomosis (OR 3.65, 95% CI 1.38-9.64, P < 0.009), and no cap-assisted gastroscope (OR 3.05, 95% CI 1.69-5.51, P < 0.001) were significantly associated with technical failure. CONCLUSIONS: ERCP is safe, effective and feasible for Billroth II gastrectomy patients. Previous ERCP history, absence of Braun anastomosis and the use of a cap-assisted gastroscope are the predictive factors for its technical success.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde/methods , Duodenum/surgery , Gastrectomy/methods , Gastroenterostomy/instrumentation , Aged , Anastomosis, Roux-en-Y/methods , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Common Bile Duct/surgery , Female , Gallstones/surgery , Humans , Male , Middle Aged , Retrospective Studies , Treatment Failure , Treatment Outcome
20.
Light Sci Appl ; 5(8): e16136, 2016 Aug.
Article in English | MEDLINE | ID: mdl-30167183

ABSTRACT

A Ln3+-doped (Yb3+, Tm3+ or Yb3+, Er3+ co-doped) NaYF4 nanoparticle/polystyrene hybrid fibrous membrane (HFM) was fabricated using an electrospinning technique. The HFM shows upconversion luminescence (UCL), flexibility, superhydrophobicity and processability. The UCL membrane can be used as a fluorescence sensor to detect bioinformation from a single water droplet (~10 µl). Based on the fluorescence resonance energy transfer, the detection limits of this sensor can reach 1 and 10 ppb for the biomolecule, avidin, and the dye molecule, Rhodamine B, respectively, which are superior to most of the fluorescence sensors reported in previous works. After the fluorescence detection, the target droplet was easily removed without residues on the UCL membrane surface due to its superhydrophobic property, which exhibits an excellent recyclability that cannot be achieved by traditional liquid-based detection systems.

SELECTION OF CITATIONS
SEARCH DETAIL
...