Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Ophthalmol ; 23(1): 439, 2023 Oct 30.
Article in English | MEDLINE | ID: mdl-37904136

ABSTRACT

BACKGROUND: To evaluate the relationship between amount of corneal refractive change (CRC) after wearing orthokeratology (Ortho-K) lenses and axial length (AL) growth. METHODS: We retrospectively enrolled 77 patients (77 eyes) aged 8-14 years who wore Ortho-K lenses more than 12 months. We divided the patients into 2 subgroups: spherical equivalent (SE) ≤ -3.0 D and SE > -3.0 D subgroup. The sagittal and tangential curvature maps and corneal topographic data within the 8-mm diameter ring at the baseline and during follow-up visits after wearing Ortho-K lens were recorded in addition to the area, height, and volume of the CRC region. The AL data were recorded at the baseline and during follow-up visits. Multivariate linear regression was conducted to analyze associations between the area, height, and volume of the CRC region, AL elongation, and SE. RESULTS: The average change in the CRC region was 9.77 ± 0.60 D in height, 16.66 ± 3.61 mm2 in area, and 87.47 ± 8.96 D*mm2 in volume on the tangential diagram after wearing Ortho-K lenses for 3 months. The AL showed a change of 0.19 ± 0.14 mm after 1 year of Ortho-K lens wear (P < 0.05). At 1 year, AL elongation was negatively correlated with the area (P = 0.019) and volume (P < 0.001) of the CRC region. At 1 year, for every 1-mm2 increase in the area and every 1-D*mm2 increase in the volume of the CRC region, the average AL elongation decreased by 0.01 mm and 0.002 mm, respectively, in the multivariate analysis. In patients with SE ≤ -3.0 D, AL elongation was negatively correlated with the CRC-region volume (ß = -0.002, P = 0.018), and in patients with SE > -3.0 D, AL elongation was negatively correlated with the CRC-region area (ß = -0.017, P = 0.016). CONCLUSIONS: The AL elongation-control efficacy of Ortho-K lenses may be related to the area and volume of the CRC region.


Subject(s)
Myopia , Orthokeratologic Procedures , Humans , Retrospective Studies , Cornea , Myopia/therapy , Refraction, Ocular , Corneal Topography , Axial Length, Eye
2.
J Ophthalmol ; 2023: 3110478, 2023.
Article in English | MEDLINE | ID: mdl-37700783

ABSTRACT

Purpose: To explore the correlation between the axial length (AL) difference (myopic and nonmyopic eye) and the refractive error in children with unilateral myopia anisometropia (UMA) and to elucidate its clinical application in the process of Ortho-K lenses review following nonstop wearing. Methods: This study retrospectively analyzed the data of 70 children with UMA (age, 8-15 years) whose myopic eyes were treated with Ortho-K lenses. The spherical equivalent refractive errors (SERE) of the myopic eye ranged from -0.75 D to -4.25 D, and astigmatism was no less than -1.50 D. In addition, SERE of nonmyopic eyes were no less than -0.50 D. AL, and the refractive data of both eyes were measured at baseline. A multivariate linear regression was used to analyze the relationship between the AL difference and refractive error, and paired t-test was used to analyze the changes in AL in both eyes. Results: Every 1 mm axial length change corresponds to -1.627 D (95% CI: -1.921 D, -1.333 D; P < 0.001) change in refractive error in children. The association between the AL change and the degree of myopia did not change with age (P=0.751). Among the 70 subjects, 51 (72.86%) had myopia in the right eye, and the 95% confidence interval (CI) for myopia occurring in the right eye was 62.4%-83.3%. The paired t-test showed that the average AL growth was significantly slower in myopic eyes treated with Ortho-K lenses than in nonmyopic eyes (t = 9.805, P < 0.001). Conclusion: Every 1 mm AL change would cause an average refractive error increase. Age did not influence the association between AL changes and the degree of myopia. The right eye is more likely to be affected in children with UMA. The Ortho-K lens treatment slowed down the growth of AL in the myopic eye in children with UMA.

3.
BMC Ophthalmol ; 22(1): 76, 2022 Feb 15.
Article in English | MEDLINE | ID: mdl-35164702

ABSTRACT

BACKGROUND: This study aimed to compare the changes in the axial length (AL) in myopic children that wear centered and decentered orthokeratology (Ortho-K). METHODS: This retrospective study included 217 subjects who were treated with an Ortho-K lens for >12 months. The subjects were divided into three groups based on the magnitude of the Ortho-K lens treatment zone decentration: mildly, moderately, and severely decentered groups. Distance and direction of treatment zone decentration were calculated using software that was developed in-house. The AL changes in different groups were compared. RESULTS: Based on the distance of the treatment zone decentration, 65 children (65 eyes) were included in the mildly decentered group, 114 children (114 eyes) in the moderately decentered group, and 38 children (38 eyes) in the severely decentered group. The mean decentration distance in the three groups was 0.35 ± 0.11 mm, 0.71 ± 0.13 mm, and 1.21 ± 0.22 mm, respectively. The mean AL increase in the three groups after 12 months of Ortho-K lens wear was 0.24 ± 0.21 mm, 0.23 ± 0.18 mm, and 0.19 ± 0.20 mm, respectively. There were no significant differences in AL changes among the three groups. CONCLUSIONS: Ortho-K lens decentration is common in clinical practice. The AL change after Ortho-K lens wear was not significantly different in subjects with different magnitudes of Ortho-K lens decentration. Fitting the Ortho-K lens in the properly centered zone is recommended to ensure the safety of Ortho-K lens wear and to maintain visual quality.


Subject(s)
Contact Lenses , Myopia , Orthokeratologic Procedures , Child , Cornea , Corneal Topography , Humans , Myopia/therapy , Refraction, Ocular , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...