Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Language
Publication year range
1.
Clinics (Sao Paulo) ; 70(10): 714-9, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26598086

ABSTRACT

The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values or the number of outliers (±3°) between the extramedullary and intramedullary groups. A reduced tourniquet time was associated with the intramedullary guide. No significant difference in the complication rate was noted between the two groups. Neither extramedullary nor intramedullary tibial alignment was more accurate in facilitating the tibial cut. Use of an intramedullary guide results in a shorter tourniquet time and exhibits a similar complication rate as the extramedullary guide.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Tibia/surgery , Bias , Humans , Radiography , Randomized Controlled Trials as Topic , Tibia/diagnostic imaging , Time Factors , Tourniquets
2.
Clinics ; Clinics;70(10): 714-719, Oct. 2015. tab, graf
Article in English | LILACS | ID: lil-762964

ABSTRACT

The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values or the number of outliers (±3°) between the extramedullary and intramedullary groups. A reduced tourniquet time was associated with the intramedullary guide. No significant difference in the complication rate was noted between the two groups. Neither extramedullary nor intramedullary tibial alignment was more accurate in facilitating the tibial cut. Use of an intramedullary guide results in a shorter tourniquet time and exhibits a similar complication rate as the extramedullary guide.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Tibia/surgery , Bias , Randomized Controlled Trials as Topic , Time Factors , Tourniquets , Tibia
SELECTION OF CITATIONS
SEARCH DETAIL