Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Drug Des Devel Ther ; 14: 4835-4843, 2020.
Article in English | MEDLINE | ID: mdl-33204069

ABSTRACT

PURPOSE: Precise and timely detection of methotrexate (MTX) concentration played a key role in high-dose MTX individualization therapy in acute lymphoblastic leukemia (ALL) children to avoid serious adverse effects or nonresponse. This report described a sensibility and validation of ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for therapeutic drug monitoring (TDM) of methotrexate concentration in children's plasma. METHODS: One-step protein precipitation of samples was accomplished by adding 200 µL of acetonitrile to 100 µL of plasma sample. The separation of plasma samples was carried out on a ZORBAX Eclipse Plus C18 Rapid Resolution HD column with gradient elution using a mobile phase constituted of acetonitrile and 1% formic acid. The detection was executed by electrospray ionization (ESI) of triple quadrupole tandem mass spectrometer (TQMS) in the multiple reaction monitoring (MRM) mode with the transitions m/z 455.2 → 307.9 for methotrexate and m/z 458.2 → 311.2 for IS, separately. Linear concentration range of the calibration curve was 44-11,000 nmol/L and 44 nmol/L was the lower limit of quantification. RESULTS: The methotrexate elution time was at 1.577 min, and the overall running time was only 3.3 min. The intra- and interday precision for all the analysis results was within 11.24%, and mean recoveries rate of methotrexate exceeded 87.98%. CONCLUSION: The described and fully validated UHPLC-MS/MS method was successfully applied in clinical TDM after infusion of high-dose methotrexate 1-5 g/m2 to 41 childpatients.


Subject(s)
Antimetabolites, Antineoplastic/therapeutic use , Drug Monitoring , Methotrexate/therapeutic use , Precursor Cell Lymphoblastic Leukemia-Lymphoma/drug therapy , Adolescent , Antimetabolites, Antineoplastic/blood , Antimetabolites, Antineoplastic/chemistry , Calibration , Child , Child, Preschool , Chromatography, High Pressure Liquid , Humans , Methotrexate/blood , Methotrexate/chemistry , Molecular Structure , Quality Assurance, Health Care , Tandem Mass Spectrometry
2.
J Anal Methods Chem ; 2019: 5016757, 2019.
Article in English | MEDLINE | ID: mdl-31886022

ABSTRACT

Anlotinib is a novel inhibitor of receptor kinase tyrosine with multitargets and has a broad spectrum of inhibitory action on tumor angiogenesis and growth. A simple and rapid UHPLC-MS/MS bioanalytical method was validated for the determination of anlotinib in rat plasma, using imatinib as an internal standard. An Acquity BEH C18 column was used to separate analytes. The eluents consisted of formic acid/water (0.1 : 100, v/v) and acetonitrile with a mobile phase. A triple quadrupole mass spectrometer was operated for the quantification with multiple reaction monitoring (MRM) to determine transitions: 408.2 ⟶ 339.1 for anlotinib, and 494.3 ⟶ 394.1 for imatinib. The validated range was 0.1-50 ng/mL for anlotinib. Mean recovery rate of anlotinib in plasma was ≥99.32% and reproducible. Also, the intra- and interday precisions were both below 15%. This robust method was successfully applied to support the pharmacokinetic study of anlotinib in rats.

SELECTION OF CITATIONS
SEARCH DETAIL
...