Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Radiol ; 70(5): e35-40, 2015 May.
Article in English | MEDLINE | ID: mdl-25727299

ABSTRACT

AIM: To evaluate the safety, efficacy, and feasibility of a novel microwave generator, designed to deliver automatically adjusted energy by tissue permittivity feedback control into the tumour via an uncooled antenna, in patients with larger hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Fourteen patients with HCC >5 cm in diameter received surgical or percutaneous microwave ablation with more than 12 months of follow-up. Microwave ablation was performed using a 902-928 MHz generator at 28 W; a single 14 G antenna without water-cooled system was used. The patients were followed up with contrast-enhanced CT and serum alpha-foetoprotein to monitor for tumour recurrence at 1 month and then every 3 months after tumour ablation. RESULTS: The follow-up duration for the 11 male and three female patients (mean tumour size 5.77 cm, range 5-7 cm; mean age 63.8 years) was 15.8 months. The mean ablation time was 2025 s (range 900-3600 s), and the mean ablation session was 2.5 (range 1-4). The complete ablation rate was 85% (17 of 20). Local recurrence rate was 5.8% (1 of 17). All patients survived and the morbidity and mortality rate was 21.4% and 0%, respectively. CONCLUSIONS: Microwave tissue ablation using this novel system with tissue permittivity feedback control and a single uncooled antenna has a high complete ablation rate and lower morbidity. It proved to be a fast, easy, and effective option for ablation of large (>5 cm) tumours.


Subject(s)
Carcinoma, Hepatocellular/surgery , Catheter Ablation/methods , Liver Neoplasms/surgery , Microwaves/therapeutic use , Adult , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media , Female , Humans , Liver Neoplasms/diagnostic imaging , Male , Middle Aged , Tomography, X-Ray Computed , Treatment Outcome
2.
Clin Radiol ; 69(5): 473-80, 2014 May.
Article in English | MEDLINE | ID: mdl-24556468

ABSTRACT

AIM: To evaluate liver necro-inflammation and function by using gadoxetic acid-enhanced dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), with histological analysis as the reference standard. MATERIALS AND METHODS: Seventy-nine subjects (21 healthy subjects; 58 chronic hepatitis patients) who received gadoxetic acid-enhanced DCE-MRI were divided into three subgroups: no (A0, n = 31), mild (A1, n = 27), and moderate-severe (A2-A3, n = 21) activities. Two DCE-MRI models were measured: (1) a dual-input single-compartment model to obtain absolute arterial, portal venous, and total blood flow, arterial fraction (ART), distribution volume, and mean transit time; (2) a curve analysis method to obtain peak, slope, and AUC (area under curve). The serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels also obtained. Statistical testing included Kruskal-Wallis tests for continuous data, Pearson's correlation tests, and multiple linear regression analyses. RESULTS: Hepatic necro-inflammatory activity grades were significantly correlated with fibrotic stages, serum ALT level, ART and AUC. ART was helpful to predict the mild activity (≤ A1 versus >A1; Az = 0.728), whereas AUC could differentiate no activity from any activity (A0 versus >A0; Az = 0.703). Peak, slope and AUC were all associated with AST and ALT (p < 0.05). CONCLUSION: Gadoxetic acid-enhanced DCE-MRI parameters may be used to evaluate the severity of hepatic necro-inflammation and function.


Subject(s)
Contrast Media , Gadolinium DTPA , Hepatitis, Chronic/enzymology , Hepatitis, Chronic/pathology , Liver/pathology , Magnetic Resonance Imaging , Perfusion Imaging , Adult , Alanine Transaminase/blood , Area Under Curve , Aspartate Aminotransferases/blood , China/epidemiology , Female , Hepatitis, Chronic/immunology , Humans , Liver/blood supply , Liver/enzymology , Male , Middle Aged , Necrosis , Predictive Value of Tests , Prospective Studies , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Severity of Illness Index
3.
Eur J Vasc Endovasc Surg ; 38(6): 741-7, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19836272

ABSTRACT

OBJECTIVES: To examine the incidence and risk factors of intraprosthetic thrombotic deposits in abdominal aortic endografts. METHODS: The clinical records of 51 patients (44 males; mean age 76.3 years, range: 63-90 years) with abdominal aortic aneurysm treated with transfemoral implantation of bifurcated stent graft between the years 2002 and 2008 were retrospectively reviewed. Patients underwent three-phase helical computed tomographic (CT) examinations at 1-, 3-, 6- and 12-month intervals and then annually. The formation of intraprosthetic thrombus associated with use of anti-platelet, preoperative mural thrombus in the aneurysm, ratio of cross-sectional area between the mainbody and bilateral limb grafts and length of mainbody were evaluated. RESULTS: Over a 10-month mean follow-up, intraluminal deposits of thrombotic material were observed in eight of 51 patients (15.6%, 95% confidence interval: 8.2-28). The first signs of thrombus formation occurred on average 9.8 months after endografting (range: 1-24 months). Intraprosthetic thrombotic deposits was not related to preoperative mural thrombus formation (p=0.38) or postoperative anti-platelet or anticoagulation medication (p=0.40). However, it was significantly related to the ratio of the cross-sectional area between the mainbody and the bilateral limb grafts and the length of mainbody (p=0.04 and p=0.01). There were three graft limbs occlusion owing to kinking with no intraprosthetic thrombus detected on CT scans taken prior to occlusion. One patient developed distal left proximal superior femoral artery embolisation 4 months after detectable intraprosthetic mainbody thrombus in a CT scan follow-up. In no case did the thrombotic deposits clear completely from the prosthesis lumen during follow-up. CONCLUSIONS: This short experience demonstrates that incidentally found thrombotic deposits in abdominal aortic endografts are common. The deposition of thrombus is mostly influenced by the geometry of the aortic stent graft with wider mainbody diameter coupled with smaller limb grafts and longer mainbody graft. Most of these thrombi are clinically silent and require no additional treatment.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Graft Occlusion, Vascular/etiology , Stents , Thrombosis/etiology , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/epidemiology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Female , Graft Occlusion, Vascular/epidemiology , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Assessment , Risk Factors , Taiwan/epidemiology , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Time Factors , Tomography, Spiral Computed , Treatment Outcome
5.
J Biomech ; 39(3): 551-63, 2006.
Article in English | MEDLINE | ID: mdl-16389096

ABSTRACT

The circulation in the liver is unique at macroscopic and microscopic levels. At the macroscopic level, there is an unusual presence of portal and arterial inputs rather than a single arterial input. At the microscopic level, a series of microenvironments in the acinar system is essential in controlling the functional characteristics of hepatic parenchymal cells. Since the hemodynamics is much less studied in the multifunctional liver, an attempt is made to study the hepatic hemodynamics in a segment of a hepatic lobular structure, that is made up of high-pressure oxygenated arteriole, low-pressure nutrient-rich portal venule, fenestrated sinusoidal space and hepatic venule. Our goal is to dispel some of the myths of this complex vascular bed by means of finite volume blood flow simulation. Flow features like high-velocity gradients near the fenestrations, flow reversal and Dean vortices in the sinusoidal space are analyzed within the non-Newtonian framework. Since no distinct exact or numerical solutions are available for this complex vascular bed, the present simulated results are compared with the available clinical observations. Results revealed that the pressure plays a key role in hepatic blood flow.


Subject(s)
Liver/blood supply , Microcirculation , Humans , Models, Theoretical , Regional Blood Flow
6.
Comput Methods Biomech Biomed Engin ; 8(4): 229-40, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16298845

ABSTRACT

Increase of temperature above 50 approximately 60 degrees C for few minutes by the emitted radio-frequency (RF) energy has been shown to be able to denaturate the intracellular proteins and destruct membranes of tumor cells. To improve the efficacy of this thermal therapy, it is important to investigate factors that may affect the RF heating characteristics for the hepatocellular carcinoma and metastatic liver tumors. In order to make sure the applied RF energy is adequate to ablate the target tumor, a 3D thermoelectric analysis for the system consisting of liver, liver arteries and 4 mm diameter tumor is conducted. The effect of blood perfusion is addressed in this study.


Subject(s)
Catheter Ablation , Liver Neoplasms/surgery , Radiofrequency Therapy , Catheter Ablation/statistics & numerical data , Computer Simulation , Computer-Aided Design , Humans , Liver Neoplasms/blood supply , Phantoms, Imaging , Temperature
7.
J Formos Med Assoc ; 99(12): 952-4, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11155752

ABSTRACT

A 54-year-old man developed priapism shortly after a blunt perineal trauma. An arteriocavernous fistula caused the high-flow priapism, and was detected on both color Doppler sonography and selective phaloarteriography. Selective embolization of the left cavernous artery with Gelfoam was performed to seal the fistula, resulting in immediate detumescence. However, the penis remained firm despite returning to almost normal size. No fistula was detected by subsequent color Doppler sonography and phaloarteriography examination. Intracavernous irrigation with 200,000 U streptokinase was applied to treat residual firmness 2 weeks after embolization. Successful sexual intercourse was reported 3 months later. The combination of selective cavernous artery embolization and intracavernous streptokinase irrigation was effective for the treatment of the high-flow priapism in this case.


Subject(s)
Embolization, Therapeutic , Fibrinolytic Agents/administration & dosage , Perineum/injuries , Priapism/therapy , Streptokinase/administration & dosage , Vascular Fistula/therapy , Arteries , Blood Flow Velocity , Combined Modality Therapy , Humans , Male , Middle Aged , Penis/blood supply , Priapism/etiology , Therapeutic Irrigation
SELECTION OF CITATIONS
SEARCH DETAIL
...