Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 60(21): 6097-6102, 2021 Jul 20.
Article in English | MEDLINE | ID: mdl-34613273

ABSTRACT

Laser frequency stabilization plays an important role in high-precision spectroscopic measurements. Since high-accuracy commercial wavemeters became available, wavemeter-based frequency stabilization has found a broad application due to its convenience, flexibility, and wide applicability. However, such stabilization schemes frequently suffer from long-term drift, since the accuracy of the wavelength measurement of a wavemeter is affected by ambient temperature fluctuation. In this work, we demonstrate that such long-term drift can be suppressed by regularly calibrating the frequency of a wavemeter-locked laser utilizing an optical frequency comb, which has much better long-term stability. Under this dual-referenced locking scheme, the Allan deviation is reduced to 3.5 E-12 at 4000 s for a fiber laser operated at 548 nm, which when used in the optical Ramsey spectroscopic measurement of 7Li+, reduces the standard deviation by as much as 40%, compared to the case when only wavemeter locking is applied.

2.
Rev Sci Instrum ; 90(9): 093301, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31575235

ABSTRACT

A low-energy, compact, and superconducting electron beam ion trap (the Shanghai-Wuhan EBIT or SW-EBIT) for extraction of highly charged ions is presented. The magnetic field in the central drift tube of the SW-EBIT is approximately 0.21 T produced by a pair of high-temperature superconducting coils. The electron-beam energy of the SW-EBIT is in the range of 30-4000 eV, and the maximum electron-beam current is up to 9 mA. Acting as a source of highly charged ions, the ion-beam optics for extraction is integrated, including an ion extractor and an einzel lens. A Wien filter is then used to measure the charge-state distribution of the extracted ions. In this work, the tungsten ions below the charge state of 15 have been produced, extracted, and analyzed. The charge-state distributions and spectra in the range of 530-580 nm of tungsten ions have been measured simultaneously with the electron-beam energy of 279 eV and 300 eV, which preliminarily indicates that the 549.9 nm line comes from W14+.

3.
Rev Sci Instrum ; 90(4): 043112, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31043027

ABSTRACT

The apparatus for fluorescence spectroscopy measurement is developed to determine the fine structure (FS)/hyperfine structure (HFS) splittings of 1s2p 3PJ(J=0,1,2) states of Li+. The instrument is composed of a low energy Li+ ion source and a saturated fluorescence spectroscopic probing system. A low energy Li+ ion source, containing 1.8(7)% of 1s2s 3S1 metastable ions with an energy of ∼500 eV, is obtained by an electron bombardment process. The ion current can stay more than 250 h with the variation of ∼0.3%, and the divergence of ion beam is ∼0.5 mrad. The symmetric profile of Lamb dip signals of 1s2s 3S1--1s2p 3PJ transitions with linewidths of ∼50 MHz are obtained after subtracting Doppler background from the saturated fluorescence signals. A back-and-forth scan method is adopted to determine the FS/HFS splittings of 1s2p 3PJ states. Under these conditions, as a preliminary test, several splittings of 7Li+ are measured. The statistical uncertainties of the FS/HFS splittings are estimated to be less than 50 kHz, and the results are one order of magnitude better than previous results. The apparatus is feasible to precisely determine the splittings of energy levels of alkali and alkaline earth ions.

SELECTION OF CITATIONS
SEARCH DETAIL
...