Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
ERJ Open Res ; 10(2)2024 Mar.
Article in English | MEDLINE | ID: mdl-38500799

ABSTRACT

Introduction: Non-cystic fibrosis bronchiectasis is a disease which is increasing in incidence and prevalence worldwide. The incidence of the disease is frequently estimated using databases that rely on International Classification of Diseases, ninth and tenth revisions, clinical modification (ICD-9-CM/ICD-10-CM) discharge diagnoses. Code accuracy has proved to be a major issue for other diagnoses using ICD codes. This study aims to investigate the accuracy of the ICD codes for the diagnosis of non-cystic fibrosis bronchiectasis. Methods: This is a retrospective diagnostic accuracy study which compares the radiologist's diagnosis of bronchiectasis with the ICD code reflection of that diagnosis at discharge. Results: Sensitivities were 34% (same for both ICD-9-CM and ICD-10-CM windows) and specificities ranged from 69% for the ICD-9-CM window to 81% for ICD-10-CM window. Conclusion: We observed that ICD codes are an insufficient method to identify patients with a radiologist diagnosis of bronchiectasis.

2.
BMC Med Imaging ; 22(1): 148, 2022 08 24.
Article in English | MEDLINE | ID: mdl-36002806

ABSTRACT

Non-cystic fibrosis bronchiectasis is a clinically important disease with an estimated 340,000-522,000 persons living with the disease and 70,000 being diagnosed annually. The radiographic diagnosis remains a pivotal part of recognizing the disease due to its protean clinical manifestations. As physicians are sensitized to this disease, a greater proportion of patients are being diagnosed with mild to moderate bronchiectasis. Despite the established use of CT chest as the main tool for making a radiologic diagnosis of bronchiectasis, the literature supporting the process of making that diagnosis is somewhat sparse. Concurrently, there has been an increased trend to have Web-based radiologic tutorials due to its convenience, the ability of the learner to set the pace of learning and the reduced cost compared to in-person learning. The COVID-19 pandemic has accelerated this trend. We wanted to look carefully at the effect of a Web-based training session on interrater reliability. Agreement was calculated as percentages and kappa and prevalence adjusted kappa calculated. We found that a single Web-based training session had little effect on the variability and accuracy of diagnosis of bronchiectasis. Larger studies are needed in this area with multiple training sessions.


Subject(s)
Bronchiectasis , COVID-19 , Bronchiectasis/diagnostic imaging , COVID-19/diagnostic imaging , COVID-19 Testing , Humans , Observer Variation , Pandemics , Reproducibility of Results
3.
J Occup Environ Med ; 51(5): 534-41, 2009 May.
Article in English | MEDLINE | ID: mdl-19365288

ABSTRACT

OBJECTIVE: To describe physical symptoms in those local residents, local workers, and cleanup workers who were enrolled in a treatment program and had reported symptoms and exposure to the dust, gas, and fumes released with the destruction of the World Trade Center (WTC) on September 11, 2001. METHODS: Symptomatic individuals underwent standardized evaluation and subsequent treatment. RESULTS: One thousand eight hundred ninety-eight individuals participated in the WTC Environmental Health Center between September 2005 and May 2008. Upper and lower respiratory symptoms that began after September 11, 2001 and persisted at the time of examination were common in each exposure population. Many (31%) had spirometry measurements below the lower limit of normal. CONCLUSIONS: Residents and local workers as well as those with work-associated exposure to WTC dust have new and persistent respiratory symptoms with lung function abnormalities 5 or more years after the WTC destruction.


Subject(s)
Air Pollutants/adverse effects , Air Pollution/adverse effects , Environmental Exposure/adverse effects , Occupational Diseases/epidemiology , Occupational Diseases/etiology , Respiration Disorders/epidemiology , Respiration Disorders/etiology , Adult , Dust , Female , Gases/adverse effects , Humans , Male , Middle Aged , New York City/epidemiology , Respiratory Function Tests , September 11 Terrorist Attacks , Spirometry , Surveys and Questionnaires
4.
Chest ; 132(4): 1275-82, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17890470

ABSTRACT

RATIONALE: Following collapse of the World Trade Center (WTC), individuals reported new-onset respiratory symptoms. Despite symptoms, spirometry often revealed normal airway function. However, bronchial wall thickening and air trapping were seen radiographically in some subjects. We hypothesized that symptomatic individuals following exposure to WTC dust may have functional abnormalities in distal airways not detectable with routine spirometry. METHODS: One hundred seventy-four subjects with respiratory symptoms and normal spirometry results were evaluated. Impedance oscillometry (IOS) was performed to determine resistance at 5 Hz, 5 to 20 Hz, and reactance area. Forty-three subjects were also tested for frequency dependence of compliance (FDC). Testing was repeated after bronchodilation. RESULTS: Predominant symptoms included cough (67%) and dyspnea (65%). Despite normal spirometry results, mean resistance at 5 Hz, 5 to 20 Hz, and reactance area were elevated (4.36 +/- 0.12 cm H(2)O/L/s, 0.86 +/- 0.05 cm H(2)O/L/s, and 6.12 +/- 0.50 cm H(2)O/L, respectively) [mean +/- SE]. Resistance and reactance normalized after bronchodilation. FDC was present in 37 of 43 individuals with improvement after bronchodilation. CONCLUSIONS: Symptomatic individuals with presumed WTC dust/fume exposure and normal spirometry results displayed airway dysfunction based on the following: (1) elevated airway resistance and frequency dependence of resistance determined by IOS; (2) heterogeneity of distal airway function demonstrated by elevated reactance area on oscillometry and FDC; and (3) reversibility of these functional abnormalities to or toward normal following administration of a bronchodilator. Since spirometry results were normal in all subjects, these abnormalities likely reflect dysfunction in airways more distal to those evaluated by spirometry. Examination of distal airway function when spirometry results are normal may be important in the evaluation of subjects exposed to occupational and environmental hazards.


Subject(s)
Bronchi/physiopathology , Dust , Environmental Exposure , September 11 Terrorist Attacks , Adult , Female , Humans , Male , Middle Aged , Oscillometry , Respiratory Function Tests , Spirometry
5.
Clin Rheumatol ; 24(2): 162-5, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15517446

ABSTRACT

Systemic lupus erythematosus (SLE), a connective tissue disease characterized by the production of auto-antibodies and immune complexes, can affect all organs including the heart. The involvement of the conduction system in SLE has been less commonly described. We report a case of an asymptomatic 45-year-old woman with SLE referred to the emergency department (ED) for thrombocytopenia, and was found to have alternating first- and second-degree atrioventricular block (AVB) during routine electrocardiographic screening for hospital admission. Serial electrocardiograms (ECG) done in the ED when compared to those recorded 24 h prior revealed progression from mild first-degree AVB (PR interval = 216 ms) to significant first-degree AVB (PR interval = 510 ms), followed by second-degree AVB (Mobitz type I-Wenckebach phenomenon). The conduction abnormalities recorded over a 28-h period resolved with corticosteroid treatment. Review of the literature on the disruption of the cardiac conduction system in SLE is discussed.


Subject(s)
Heart Block/etiology , Lupus Erythematosus, Systemic/complications , Electrocardiography , Female , Heart Block/diagnosis , Heart Block/epidemiology , Humans , Lupus Erythematosus, Systemic/epidemiology , Middle Aged , Prevalence , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...