Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
G Ital Nefrol ; 40(1)2023 Feb 27.
Article in Italian | MEDLINE | ID: mdl-36883918

ABSTRACT

High-output cardiac failure is a well-known phenomenon of high-flow fistula in hemodialysis patients. The definition of "high flow" is varied and almost always connected to proximal arteriovenous fistulas (AVF). High flow access is a condition in which hemodynamics is affected by a greater rate of blood flow required for hemodialysis and this can compromise circulatory dynamics, particularly in the elderly in the context of pre-existing heart disease. High access flow is associated with complications like high output heart failure, pulmonary hypertension, massively dilated fistula, central vein stenosis, dialysis associated steal syndrome or distal hypoperfusion ischemic syndrome. Although there is no single agreement about the values of AVF flow volume, nor about the definition of high-flow AVF, there is no doubt that AVF flow should be considered too high if signs of cardiac failure develop. The exact threshold for defining high flow access has not been validated or universally accepted by the guidelines, although a vascular access flow rate of 1 to 1.5 l/min has been suggested. Moreover, even lower values may be indicative of relatively excessive blood flow, depending on the patient's condition. The pathophysiology contributing to this disease process is the shunting of blood from the high-resistance arterial system into the lower resistance venous system, increasing the venous return up to cardiac failure. Accurate and well-timed diagnosis of high flow arteriovenous hemodynamics by monitoring of blood flow of fistula and cardiac function is required in order to stop this process prior to cardiac failure. We present two cases of patients with high flow arteriovenous fistula with a review of the literature.


Subject(s)
Arteriovenous Fistula , Arteriovenous Shunt, Surgical , Heart Failure , Humans , Aged , Arteriovenous Shunt, Surgical/adverse effects , Hemodynamics , Renal Dialysis/adverse effects , Heart Failure/etiology , Arteriovenous Fistula/complications
2.
G Ital Nefrol ; 35(4)2018 Jul.
Article in Italian | MEDLINE | ID: mdl-30035446

ABSTRACT

The diagnosis of renal masses has increased in the last decades owing to the widespread use of imaging (ultrasound, computed tomography and magnetic resonance). Majority of the renal masses are detected incidentally on routine ultrasound examination. Solid masses detected on ultrasound require further imaging evaluation with CT and/or MRI for suitable characterization. US-guided renal biopsy is a safe, effective and accurate method for evaluating the small renal masses with ambiguous radiologic findings. Navigation technology and multimodality image fusion represent an important development in interventional radiology, especially for performing difficult percutaneous biopsies and ablations of small renal masses. Multidisciplinary approach is required which results from experience and knowledge and in hard cases the use of serial imaging can be helpful.


Subject(s)
Kidney Diseases/diagnostic imaging , Kidney Neoplasms/diagnostic imaging , Adult , Aged , Humans , Incidental Findings , Male , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...