1.
Indoor Air ; 28(3): 404-414, 2018 05.
Article in English | MEDLINE | ID: mdl-29444354

ABSTRACT

Strong evidence suggests that clothing serves as a reservoir of chemical pollutants and particles, including bioaerosols, which may have health significance. However, little is known about the role that clothing may play as a transport vector for inhaled airborne particles. Here, we contribute toward bridging the knowledge gap by conducting experiments to investigate clothing release fraction (CRF), determined as the size-dependent ratio of released to deposited particulate matter in the diameter range 0.5-10 µm. In a fully controlled chamber with low background particle levels, we deployed a programmable robot to reproducibly quantify the size-dependent CRF as a function of motion type and intensity, dust loadings, and activity duration. On average, 0.3%-3% of deposited particles were subsequently released with fabric motion, confirming that clothing can act as a vehicle for transporting airborne particles. The CRF increased with the vigor of movement and with dust loading. Rubbing and shaking the fabric were more effective than fabric stretching in resuspending particles. We also found that most of the release happened quickly after the onset of the resuspension activity. Particle size substantially influenced the CRF, with larger particles exhibiting higher values.


Subject(s)
Air Pollutants/analysis , Air Pollution, Indoor/analysis , Clothing , Particulate Matter/analysis , Textiles/analysis , Aerosols/analysis , Dust/analysis , Environmental Monitoring/methods , Humans , Inhalation Exposure/analysis , Particle Size
2.
Indoor Air ; 27(4): 791-802, 2017 07.
Article in English | MEDLINE | ID: mdl-28009455

ABSTRACT

Inhalation exposure to elevated particulate matter levels is correlated with deleterious health and well-being outcomes. Despite growing evidence that identifies humans as sources of coarse airborne particles, the extent to which personal exposures are influenced by particle releases near occupants is unknown. In a controlled chamber, we monitored airborne total particle levels with high temporal and particle-size resolution for a range of simulated occupant activities. We also sampled directly from the subject's breathing zone to characterize exposures. A material-balance model showed that a sitting occupant released 8 million particles/h in the diameter range 1-10 µm. Elevated emissions were associated with increased intensity of upper body movements and with walking. Emissions were correlated with exposure, but not linearly. The personal PM10 exposure increment above the room-average levels was 1.6-13 µg/m3 during sitting, owing to spatial heterogeneity of particulate matter concentrations, a feature that was absent during walking. The personal cloud was more discernible among larger particles, as would be expected for shedding from skin and clothing. Manipulating papers and clothing fabric was a strong source of airborne particles. An increase in personal exposure was observed owing to particle mass exchange associated with a second room occupant.


Subject(s)
Aerosols/analysis , Environmental Exposure/analysis , Inhalation Exposure/analysis , Particulate Matter/analysis , Adult , Air Pollutants/analysis , Air Pollution, Indoor/analysis , Clothing , Computer Simulation , Environmental Monitoring/methods , Female , Humans , Male , Particle Size , Respiration , Sedentary Behavior , Walking
3.
Indoor Air ; 25(6): 683-93, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25615014

ABSTRACT

UNLABELLED: The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant. PRACTICAL IMPLICATIONS: The results from this study show that an advanced air distribution system such as personalized ventilation reduces exposure to cough-released droplets better than commonly applied overhead mixing ventilation. This work can inform HVAC engineers about different aspects of air distribution systems' performance and can serve as an aid in making critical design decisions.


Subject(s)
Air Pollution, Indoor , Cough , Ventilation , Aerosols , Air Movements , Computer Simulation , Humans , Manikins
4.
Indoor Air ; 25(6): 672-82, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25515610

ABSTRACT

UNLABELLED: The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, size, and surface temperatures correspond to those of an average person is used to simulate the CBL. The findings of the study reveal that for accurate predictions of personal exposure, the CBL needs to be considered, as it can transport the pollution around the human body. The best way to control and reduce personal exposure when the pollution originates at the feet is to employ transverse flow from in front and from the side, relative to the exposed occupant. The flow from the above opposing the CBL create the most unfavorable velocity field that can increase personal exposure by 85%, which demonstrates a nonlinear dependence between the supplied flow rate and personal exposure. In the current ventilation design, it is commonly accepted that an increased amount of air supplied to the rooms reduces the exposure. The results of this study suggest that the understanding of air patterns should be prioritized. PRACTICAL IMPLICATIONS: A human convective boundary layer plays an important role in pollution transport around the human body. It interacts with the surrounding airflows which modifies air movement around the human body and personal exposure. Understanding the influence of this interaction on the pollution spread around the human can be used to control and reduce personal exposure and improve HVAC design.


Subject(s)
Air Pollution, Indoor , Ventilation , Air Movements , Convection , Cough , Humans , Manikins , Respiration
5.
Indoor Air ; 25(1): 21-35, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24750235

ABSTRACT

This study investigates the interaction between the human convective boundary layer (CBL) and uniform airflow with different velocity and from different directions. Human body is resembled by a thermal manikin with complex body shape and surface temperature distribution as the skin temperature of an average person. Particle image velocimetry (PIV) and pseudocolor visualization (PCV) are applied to identify the flow around the manikin's body. The findings show that the direction and magnitude of the surrounding airflows considerably influence the airflow distribution around the human body. Downward flow with velocity of 0.175 m/s does not influence the convective flow in the breathing zone, while flow at 0.30 m/s collides with the CBL at the nose level reducing the peak velocity from 0.185 to 0.10 m/s. Transverse horizontal flow disturbs the CBL at the breathing zone even at 0.175 m/s. A sitting manikin exposed to airflow from below with velocity of 0.30 and 0.425 m/s assisting the CBL reduces the peak velocity in the breathing zone and changes the flow pattern around the body, compared to the assisting flow of 0.175 m/s or quiescent conditions. In this case, the airflow interaction is strongly affected by the presence of the chair.


Subject(s)
Air Movements , Respiration , Skin Physiological Phenomena , Ventilation , Air Pollution, Indoor , Biophysics , Body Temperature , Female , Humans , Manikins , Particulate Matter/analysis
SELECTION OF CITATIONS