1.
Phys Med ; 31(6): 627-33, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25982304

ABSTRACT

Radiosurgery (RS) treatment times vary, even for the same prescription dose, due to variations in the collimator size, the number of iso-centres/beams/arcs used and the time gap between each of these exposures. The biologically effective dose (BED) concept, incorporating fast and slow components of repair, was used to show the likely influence of these variables for Gamma Knife patients with Vestibular Schwannomas. Two patients plans were selected, treated with the Model B Gamma Knife, these representing the widest range of treatment variables; iso-centre numbers 3 and 13, overall treatment times 25.4 and 129.6 min, prescription dose 14 Gy. These were compared with 3 cases treated with the Perfexion(®) Gamma Knife. The iso-centre number varied between 11 and 18, treatment time 35.7 - 74.4 min, prescription dose 13 Gy. In the longer Model B Gamma Knife treatment plan the 14 Gy iso-dose was best matched by the 58 Gy2.47 iso-BED line, although higher and lower BED values were associated with regions on the prescription iso-dose. The equivalent value for the shorter treatment was 85 Gy2.47. BED volume histograms showed that a BED of 85 Gy2.47 only covered ∼65% of the target in the plan with the longer overall treatment time. The corresponding BED values for the 3 cases, treated with the Perfexion(®) Gamma Knife, were 59.5, 68.5 and 71.5 Gy2.47. In conclusion BED calculations, taking account of the repair of sublethal damage, may indicate the importance of reporting overall time to reflect the biological effectiveness of the total physical dose applied.


Subject(s)
Models, Biological , Neuroma, Acoustic/surgery , Radiometry/methods , Radiosurgery/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Humans
2.
J Radiosurg SBRT ; 2(4): 257-271, 2013.
Article in English | MEDLINE | ID: mdl-29296371

ABSTRACT

In the application of stereotactic radiosurgery, using the Gamma Knife, there are large variations in the overall treatment time for the same prescription dose, given in a single treatment session, for different patients. This is due to not only changes in the activity of the Cobolt-60 sources, but also to variations in the number of iso-centers used, the collimator size for a particular iso-center, and the time gap between the different iso-centers. Although frequently viewed as a single dose treatment the concept of biologically effective dose (BED), incorporating concurrent fast and a slow components of repair of sublethal damage, would imply potential variations in BED because of the influence of these different variables associated with treatment. This was investigated in 26 patients, treated for Vestibular Schwannomas, using the Series B Gamma-Knife, between 1999 and 2005. The iso-center number varied between 2 and 13, and the overall treatment time from 25.4-129.58 min. The prescription doses varied from 10-14 Gy. To obtain physical dose and dose-rates from each iso-center, in a number of locations in the region of interest, a prototype version of the Leksell GammaPlan® was used. For an individual patient, BED values varied by up to 15% for a given physical iso-dose. This was due to variation in the dose prescription at different locations on that iso-dose. Between patients there was a decline in the range of BED values as the overall treatment time increased. This increased treatment time was partly a function of the slow decline in the activity of the sources with time but predominantly due to changes in the number of iso-centers used. Thus, variations in BED values did not correlate with prescription dose but was modified by the overall treatment time.

SELECTION OF CITATIONS
SEARCH DETAIL
...