Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J AOAC Int ; 106(6): 1550-1563, 2023 Nov 02.
Article in English | MEDLINE | ID: mdl-37701991

ABSTRACT

BACKGROUND: In response to the growing global need for pesticide residue testing, laboratories must develop versatile analytical methods and workflows to produce scientifically sound results. One of the many challenges faced by food chemists is acquiring suitable pesticide certified reference materials (CRMs) to calibrate analytical equipment, monitor method performance, and confirm the identity and concentration of hundreds of pesticide residues in food samples. CRM producers invest considerable resources to ensure the stability of their products. OBJECTIVE: To present proper CRM handling and storage practices as guidance to ensure stability based on the results of several multiresidue pesticide stability studies. METHODS: The open ampoule and combined multiresidue mix studies were conducted under controlled conditions. New ampoules containing multiresidue pesticide CRM mixtures were opened and compared to previously opened ampoules at multiple intervals while stored under freezing and refrigerated temperatures. Both LC- and GC-amenable pesticides (>200 residues) were combined and stored under typical laboratory conditions. Studies were performed with and without celery matrix. RESULTS: The open ampoule study showed high levels of stability for all mixtures. All GC residues remained stable over the duration of the experiment. A week after opening LC multiresidue pesticide mixtures showed minor degradation. After combination of the multiresidue pesticide mixtures, degradation occurred rapidly for both the GC and LC mixtures. CONCLUSION: Multiresidue pesticide mixtures are stable as ampullated until they are opened. Once the contents of a kit were opened and combined, decreasing stability was observed over time. This was true for both the LC and GC kits. Working mixtures of CRMs for instrument calibration should be made daily. HIGHLIGHTS: This article shows a novel approach for measuring stability of CRM mixes. In-depth analysis of multiresidue pesticide mixtures and the stability that can be expected before and after mixing under typical storage conditions is described.


Subject(s)
Pesticide Residues , Pesticides , Tandem Mass Spectrometry/methods , Pesticides/analysis , Gas Chromatography-Mass Spectrometry , Chromatography, Liquid/methods , Pesticide Residues/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...