Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 10(10)2023 Oct 09.
Article in English | MEDLINE | ID: mdl-37892904

ABSTRACT

Graft fixation during cruciate ligament reconstruction using interference screws is a common and frequently used surgical technique. These interference screws are usually made of metal or bioabsorbable materials. This paper describes the development of an allograft interference screw from cortical human bone. During the design of the screw, particular attention was paid to the choice of the screw drive and the screw shape, as well as the thread shape. Based on these parameters, a prototype was designed and manufactured. Subsequently, the first biomechanical tests using a bovine model were performed. The test procedure comprised a torsion test to determine the ultimate failure torque of the screw and the insertion torque during graft fixation, as well as a pull-out test to asses the ultimate failure load of the graft fixation. The results of the biomechanical analysis showed that the mean value of the ultimate failure torque was 2633 Nmm, whereas the mean occurring insertion torque during graft fixation was only 1125 Nmm. The mean ultimate failure load of the graft fixation was approximately 235 N. The results of this work show a good overall performance of the allograft screw compared to conventional screws, and should serve as a starting point for further detailed investigations and studies.

2.
Beilstein J Nanotechnol ; 13: 1268-1283, 2022.
Article in English | MEDLINE | ID: mdl-36447565

ABSTRACT

Nanofibers are drawing the attention of engineers and scientists because their large surface-to-volume ratio is favorable for applications in medicine, filter technology, textile industry, lithium-air batteries, and optical sensors. However, when transferring nanofibers to a technical product in the form of a random network of fibers, referred to as nonwoven fabric, the stickiness of the freshly produced and thus fragile nanofiber nonwoven remains a problem. This is mainly because nanofibers strongly adhere to any surface because of van der Waals forces. In nature, there are animals that are actually able to efficiently produce, process, and handle nanofibers, namely cribellate spiders. For that, the spiders use the calamistrum, a comb-like structure of modified setae on the metatarsus of the hindmost (fourth) legs, to which the 10-30 nm thick silk nanofibers do not stick due to a special fingerprint-like surface nanostructure. In this work, we present a theoretical model of the interaction of linear nanofibers with a sinusoidally corrugated surface. This model allows for a prediction of the adhesive interaction and, thus, the design of a suitable surface structure to prevent sticking of an artificially nonwoven of nanofibers. According to the theoretical prediction, a technical analogon of the nanoripples was produced by ultrashort pulse laser processing on different technically relevant metal surfaces in the form of so-called laser-induced periodic surface structures (LIPSS). Subsequently, by means of a newly established peel-off test, the adhesion of an electrospun polyamide fiber-based nonwoven was quantified on such LIPSS-covered aluminium alloy, steel, and titanium alloy samples, as well as on polished (flat) control samples as reference and, additionally, on samples with randomly rough surfaces. The latter revealed that the adhesion of electrospun nanofiber nonwoven is significantly lowered on the nanostructured surfaces compared with the polished surfaces.

3.
Bioengineering (Basel) ; 8(10)2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34677209

ABSTRACT

Due to their osteoconductive properties, allogenic bone screws made of human cortical bone have advantages regarding rehabilitation compared to other materials such as stainless steel or titanium. Since conventional screw drives like hexagonal or hexalobular drives are difficult to manufacture in headless allogenic screws, an easy-to-manufacture screw drive is needed. In this paper, we present a simple drive for headless allogenic bone screws that allows the screw to be fully inserted. Since the screw drive is completely internal, no threads are removed. In order to prove the mechanical strength, we performed simulations of the new drive using the Finite-Element method (FEM), validated the simulations with a prototype screw, tested the novel screw drive experimentally and compared the simulations with conventional drives. The validation with the prototype showed that our simulations provided valid results. Furthermore, the simulations of the new screw drive showed good performance in terms of mechanical strength in allogenic screws compared to conventional screw drives. The presented screw drive is simple and easy to manufacture and is therefore suitable for headless allogenic bone screws where conventional drives are difficult to manufacture.

4.
Open Res Eur ; 1: 5, 2021.
Article in English | MEDLINE | ID: mdl-37645117

ABSTRACT

Background: During the coronavirus disease 2019 (COVID-19) pandemic face masks grew in importance as their use by the general population was recommended by health officials in order to minimize the risk of infection and prevent further spread of the virus. To ensure health protection of medical personnel and other system relevant staff, it is of considerable interest to quickly test if a certain lot of filtering facepiece masks meets the requirements or if the penetration changes under different conditions. As certified penetrometers are rather expensive and were difficult to obtain during the COVID-19 pandemic, we describe two quite simple and cheap methods to quickly test the filter penetration based on an electronic cigarette. Methods: The first method uses a precision scale, the second method uses a light scattering detector to measure the filter penetration. To make sure these two methods yield reliable results, both were tested with freshly cut filter samples covering the range of approx. 2 % to 60 % filter penetration and compared to the results of a certified penetrometer. Results: The comparison of the two methods with the certified penetrometer showed a good correlation and therefore allow a quick and rather reliable estimation of the penetration. Conclusions: Several examples about the use of faulty masks and the resulting health risks show that simple, fast, cheap and broadly available methods for filter characterization might be useful in these days.

SELECTION OF CITATIONS
SEARCH DETAIL
...