Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE J Biomed Health Inform ; 26(12): 5983-5991, 2022 12.
Article in English | MEDLINE | ID: mdl-36121947

ABSTRACT

Breathing pattern has been shown to be different in chronic obstructive pulmonary disease (COPD) patients compared to healthy controls during rest and walking. In this study we evaluated respiratory parameters and the breathing variability of COPD patients as a function of their severity. Thoracic bioimpedance was acquired on 66 COPD patients during the performance of the six-minute walk test (6MWT), as well as 5 minutes before and after the test while the patients were seated, i.e. resting and recovery phases. The patients were classified by their level of airflow limitation into moderate and severe groups. We characterized the breathing patterns by evaluating common respiratory parameters using only wearable bioimpedance. Specifically, we computed the median and the coefficient of variation of the parameters during the three phases of the protocol, and evaluated the statistical differences between the two COPD severity groups. We observed significant differences between the COPD severity groups only during the sitting phases, whereas the behavior during the 6MWT was similar. Particularly, we observed an inverse relationship between breathing pattern variability and COPD severity, which may indicate that the most severely diseased patients had a more restricted breathing compared to the moderate patients.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Wearable Electronic Devices , Humans , Pulmonary Disease, Chronic Obstructive/diagnosis , Lung , Respiration , Walk Test
2.
Comput Methods Programs Biomed ; 225: 107020, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35905697

ABSTRACT

BACKGROUND AND OBJECTIVE: Chronic obstructive pulmonary disease (COPD) requires a multifactorial assessment, evaluating the airflow limitation and symptoms of the patients. The 6-min walk test (6MWT) is commonly used to evaluate the functional exercise capacity in these patients. This study aims to propose a novel predictive model of the major 6MWT outcomes for COPD assessment, without physical performance measurements. METHODS: Cardiopulmonary and clinical parameters were obtained from fifty COPD patients. These parameters were used as inputs of a Bayesian network (BN), which integrated three multivariate models including the 6-min walking distance (6MWD), the maximum HR (HRmax) after the walking, and the HR decay 3 min after (HRR3). The use of BN allows the assessment of the patients' status by predicting the 6MWT outcomes, but also inferring disease severity parameters based on actual patient's 6MWT outcomes. RESULTS: Firstly, the correlation obtained between the estimated and actual 6MWT measures was strong (R = 0.84, MAPE = 8.10% for HRmax) and moderate (R = 0.58, MAPE = 15.43% for 6MWD and R = 0.58, MAPE = 32.49% for HRR3), improving the classical methods to estimate 6MWD. Secondly, the classification of disease severity showed an accuracy of 78.3% using three severity groups, which increased up to 84.4% for two defined severity groups. CONCLUSIONS: We propose a powerful two-way assessment tool for COPD patients, capable of predicting 6MWT outcomes without the need for an actual walking exercise. This model-based tool opens the way to implement a continuous monitoring system for COPD patients at home and to provide more personalized care.


Subject(s)
Exercise Tolerance , Pulmonary Disease, Chronic Obstructive , Bayes Theorem , Exercise Test/methods , Humans , Physical Functional Performance , Pulmonary Disease, Chronic Obstructive/diagnosis , Walking
3.
Front Bioeng Biotechnol ; 10: 806761, 2022.
Article in English | MEDLINE | ID: mdl-35237576

ABSTRACT

Changes in respiratory rate have been found to be one of the early signs of health deterioration in patients. In remote environments where diagnostic tools and medical attention are scarce, such as deep space exploration, the monitoring of the respiratory signal becomes crucial to timely detect life-threatening conditions. Nowadays, this signal can be measured using wearable technology; however, the use of such technology is often hampered by the low quality of the recordings, which leads more often to wrong diagnosis and conclusions. Therefore, to apply these data in diagnosis analysis, it is important to determine which parts of the signal are of sufficient quality. In this context, this study aims to evaluate the performance of a signal quality assessment framework, where two machine learning algorithms (support vector machine-SVM, and convolutional neural network-CNN) were used. The models were pre-trained using data of patients suffering from chronic obstructive pulmonary disease. The generalization capability of the models was evaluated by testing them on data from a different patient population, presenting normal and pathological breathing. The new patients underwent bariatric surgery and performed a controlled breathing protocol, displaying six different breathing patterns. Data augmentation (DA) and transfer learning (TL) were used to increase the size of the training set and to optimize the models for the new dataset. The effect of the different breathing patterns on the performance of the classifiers was also studied. The SVM did not improve when using DA, however, when using TL, the performance improved significantly (p < 0.05) compared to DA. The opposite effect was observed for CNN, where the biggest improvement was obtained using DA, while TL did not show a significant change. The models presented a low performance for shallow, slow and fast breathing patterns. These results suggest that it is possible to classify respiratory signals obtained with wearable technologies using pre-trained machine learning models. This will allow focusing on the relevant data and avoid misleading conclusions because of the noise, when designing bio-monitoring systems.

4.
IEEE Trans Biomed Eng ; 68(1): 298-307, 2021 01.
Article in English | MEDLINE | ID: mdl-32746014

ABSTRACT

Chronic Obstructive Pulmonary Disease (COPD) is one of the most common chronic conditions. The current assessment of COPD requires a maximal maneuver during a spirometry test to quantify airflow limitations of patients. Other less invasive measurements such as thoracic bioimpedance and myographic signals have been studied as an alternative to classical methods as they provide information about respiration. Particularly, strong correlations have been shown between thoracic bioimpedance and respiratory volume. The main objective of this study is to investigate bioimpedance and its combination with myographic parameters in COPD patients to assess the applicability in respiratory disease monitoring. We measured bioimpedance, surface electromyography and surface mechanomyography in forty-three COPD patients during an incremental inspiratory threshold loading protocol. We introduced two novel features that can be used to assess COPD condition derived from the variation of bioimpedance and the electrical and mechanical activity during each respiratory cycle. These features demonstrate significant differences between mild and severe patients, indicating a lower inspiratory contribution of the inspiratory muscles to global respiratory ventilation in the severest COPD patients. In conclusion, the combination of bioimpedance and myographic signals provides useful indices to noninvasively assess the breathing of COPD patients.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Respiratory Muscles , Humans , Lung Volume Measurements , Pulmonary Disease, Chronic Obstructive/diagnosis , Respiration , Spirometry
5.
J Cardiovasc Transl Res ; 13(5): 769-782, 2020 10.
Article in English | MEDLINE | ID: mdl-31848881

ABSTRACT

In this study, the effects of moderate intense endurance exercise on heart and kidney function and morphology were studied in a thoracic inferior vena cava constricted (IVCc) rat model of abdominal venous congestion. After IVC surgical constriction, eight sedentary male Sprague-Dawley IVCc rats (IVCc-SED) were compared to eight IVCc rats subjected to moderate intense endurance exercise (IVCc-MOD). Heart and kidney function was examined and renal functional reserve (RFR) was investigated by administering a high protein diet (HPD). After 12 weeks of exercise training, abdominal venous pressure, indices of body fat content, plasma cystatin C levels, and post-HPD urinary KIM-1 levels were all significantly lower in IVCc-MOD versus IVCc-SED rats (P < 0.05). RFR did not differ between both groups. The implementation of moderate intense endurance exercise in the IVCc model reduces abdominal venous pressure and is beneficial to kidney function.


Subject(s)
Exercise Therapy , Hyperemia/therapy , Kidney/physiopathology , Physical Endurance , Animals , Biomarkers/blood , Biomarkers/urine , Cell Adhesion Molecules/urine , Cystatin C/blood , Disease Models, Animal , Hyperemia/metabolism , Hyperemia/physiopathology , Kidney/metabolism , Ligation , Male , Pilot Projects , Rats, Sprague-Dawley , Vena Cava, Inferior/physiopathology , Vena Cava, Inferior/surgery , Venous Pressure
SELECTION OF CITATIONS
SEARCH DETAIL
...