1.
Photoacoustics ; 32: 100539, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37600964

ABSTRACT

Photoacoustic imaging (PAI), also referred to as optoacoustic imaging, has shown promise in early-stage clinical trials in a range of applications from inflammatory diseases to cancer. While the first PAI systems have recently received regulatory approvals, successful adoption of PAI technology into healthcare systems for clinical decision making must still overcome a range of barriers, from education and training to data acquisition and interpretation. The International Photoacoustic Standardisation Consortium (IPASC) undertook an community exercise in 2022 to identify and understand these barriers, then develop a roadmap of strategic plans to address them. Here, we outline the nature and scope of the barriers that were identified, along with short-, medium- and long-term community efforts required to overcome them, both within and beyond the IPASC group.

2.
Magn Reson Med ; 86(5): 2552-2561, 2021 11.
Article in English | MEDLINE | ID: mdl-34184306

ABSTRACT

PURPOSE: In vivo MR elastography (MRE) holds promise as a neuroimaging marker. In cerebral MRE, shear waves are introduced into the brain, which also stimulate vibrations in adjacent CSF, resulting in blurring and biased stiffness values near brain surfaces. We here propose inversion-recovery MRE (IR-MRE) to suppress CSF signal and improve stiffness quantification in brain surface areas. METHODS: Inversion-recovery MRE was demonstrated in agar-based phantoms with solid-fluid interfaces and 11 healthy volunteers using 31.25-Hz harmonic vibrations. It was performed by standard single-shot, spin-echo EPI MRE following 2800-ms IR preparation. Wave fields were acquired in 10 axial slices and analyzed for shear wave speed (SWS) as a surrogate marker of tissue stiffness by wavenumber-based multicomponent inversion. RESULTS: Phantom SWS values near fluid interfaces were 7.5 ± 3.0% higher in IR-MRE than MRE (P = .01). In the brain, IR-MRE SNR was 17% lower than in MRE, without influencing parenchymal SWS (MRE: 1.38 ± 0.02 m/s; IR-MRE: 1.39 ± 0.03 m/s; P = .18). The IR-MRE tissue-CSF interfaces appeared sharper, showing 10% higher SWS near brain surfaces (MRE: 1.01 ± 0.03 m/s; IR-MRE: 1.11 ± 0.01 m/s; P < .001) and 39% smaller ventricle sizes than MRE (P < .001). CONCLUSIONS: Our results show that brain MRE is affected by fluid oscillations that can be suppressed by IR-MRE, which improves the depiction of anatomy in stiffness maps and the quantification of stiffness values in brain surface areas. Moreover, we measured similar stiffness values in brain parenchyma with and without fluid suppression, which indicates that shear wavelengths in solid and fluid compartments are identical, consistent with the theory of biphasic poroelastic media.


Subject(s)
Elasticity Imaging Techniques , Brain/diagnostic imaging , Echo-Planar Imaging , Humans , Magnetic Resonance Imaging , Phantoms, Imaging , Vibration
3.
Magn Reson Med ; 85(3): 1655-1668, 2021 03.
Article in English | MEDLINE | ID: mdl-32902011

ABSTRACT

PURPOSE: Biological soft tissues often have a porous architecture comprising fluid and solid compartments. Upon displacement through physiological or externally induced motion, the relative motion of these compartments depends on poroelastic parameters, such as coupling density ( ρ12 ) and tissue porosity. This study introduces inversion recovery MR elastography (IR-MRE) (1) to quantify porosity defined as fluid volume over total volume, (2) to separate externally induced shear strain fields of fluid and solid compartments, and (3) to quantify coupling density assuming a biphasic behavior of in vivo brain tissue. THEORY AND METHODS: Porosity was measured in eight tofu phantoms and gray matter (GM) and white matter (WM) of 21 healthy volunteers. Porosity of tofu was compared to values obtained by fluid draining and microscopy. Solid and fluid shear-strain amplitudes and ρ12 were estimated both in phantoms and in in vivo brain. RESULTS: T1 -based measurement of tofu porosity agreed well with reference values (R = 0.99, P < .01). Brain tissue porosity was 0.14 ± 0.02 in GM and 0.05 ± 0.01 in WM (P < .001). Fluid shear strain was found to be phase-locked with solid shear strain but had lower amplitudes in both tofu phantoms and brain tissue (P < .05). In accordance with theory, tofu and brain ρ12 were negative. CONCLUSION: IR-MRE allowed for the first time separation of shear strain fields of solid and fluid compartments for measuring coupling density according to the biphasic theory of poroelasticity. Thus, IR-MRE opens horizons for poroelastography-derived imaging markers that can be used in basic research and diagnostic applications.


Subject(s)
Elasticity Imaging Techniques , Brain/diagnostic imaging , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Phantoms, Imaging
4.
Magn Reson Med ; 85(4): 1962-1973, 2021 04.
Article in English | MEDLINE | ID: mdl-33104294

ABSTRACT

PURPOSE: With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath-hold. However, breath-hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free-breathing strategies in multifrequency MRE of abdominal organs. METHODS: Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single-shot, multislice, full wave-field acquisition was performed four times in 11 healthy volunteers: once with multiple breath-holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian. RESULTS: Total scan times ranged from 120 seconds for ungated free-breathing MRE to 376 seconds for breath-hold examinations. As expected, free-breathing MRE resulted in larger organ displacements (liver, 4.7 ± 1.5 mm; kidneys, 2.4 ± 2.2 mm; spleen, 3.1 ± 2.4 mm; pancreas, 3.4 ± 1.4 mm) than breath-hold MRE (liver, 0.7 ± 0.2 mm; kidneys, 0.4 ± 0.2 mm; spleen, 0.5 ± 0.2 mm; pancreas, 0.7 ± 0.5 mm). Nonetheless, breathing-related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 ± 0.07 m/s; kidneys, 2.35 ± 0.21 m/s; spleen, 2.02 ± 0.15 m/s; pancreas, 1.39 ± 0.15 m/s). Image registration before inversion improved the quality of free-breathing examinations, yielding no differences in image sharpness to uncorrected breath-hold MRE in most organs (P > .05). CONCLUSION: Overall, multifrequency MRE is robust to breathing when considering whole-organ values. Respiration-related blurring can readily be corrected using image registration. Consequently, ungated free-breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.


Subject(s)
Elasticity Imaging Techniques , Abdomen/diagnostic imaging , Artifacts , Humans , Liver/diagnostic imaging , Magnetic Resonance Imaging , Respiration
5.
Front Physiol ; 11: 605205, 2020.
Article in English | MEDLINE | ID: mdl-33329058

ABSTRACT

During pregnancy, the body's hyperestrogenic state alters hepatic metabolism and synthesis. While biochemical changes related to liver function during normal pregnancy are well understood, pregnancy-associated alterations in biophysical properties of the liver remain elusive. In this study, we investigated 26 ex vivo fresh liver specimens harvested from pregnant and non-pregnant rats by diffusion-weighted imaging (DWI) and magnetic resonance elastography (MRE) in a 0.5-Tesla compact magnetic resonance imaging (MRI) scanner. Water diffusivity and viscoelastic parameters were compared with histological data and blood markers. We found livers from pregnant rats to have (i) significantly enlarged hepatocytes (26 ± 15%, p < 0.001), (ii) increased liver stiffness (12 ± 15%, p = 0.012), (iii) decreased viscosity (-23 ± 14%, p < 0.001), and (iv) increased water diffusivity (12 ± 11%, p < 0.001). In conclusion, increased stiffness and reduced viscosity of the liver during pregnancy are mainly attributable to hepatocyte enlargement. Hypertrophy of liver cells imposes fewer restrictions on intracellular water mobility, resulting in a higher hepatic water diffusion coefficient. Collectively, MRE and DWI have the potential to inform on structural liver changes associated with pregnancy in a clinical context.

6.
Proc Natl Acad Sci U S A ; 117(1): 128-134, 2020 01 07.
Article in English | MEDLINE | ID: mdl-31843897

ABSTRACT

Mechanical properties of biological tissues and, above all, their solid or fluid behavior influence the spread of malignant tumors. While it is known that solid tumors tend to have higher mechanical rigidity, allowing them to aggressively invade and spread in solid surrounding healthy tissue, it is unknown how softer tumors can grow within a more rigid environment such as the brain. Here, we use in vivo magnetic resonance elastography (MRE) to elucidate the role of anomalous fluidity for the invasive growth of soft brain tumors, showing that aggressive glioblastomas (GBMs) have higher water content while behaving like solids. Conversely, our data show that benign meningiomas (MENs), which contain less water than brain tissue, are characterized by fluid-like behavior. The fact that the 2 tumor entities do not differ in their soft properties suggests that fluidity plays an important role for a tumor's aggressiveness and infiltrative potential. Using tissue-mimicking phantoms, we show that the anomalous fluidity of neurotumors physically enables GBMs to penetrate surrounding tissue, a phenomenon similar to Saffman-Taylor viscous-fingering instabilities, which occur at moving interfaces between fluids of different viscosity. Thus, targeting tissue fluidity of malignant tumors might open horizons for the diagnosis and treatment of cancer.


Subject(s)
Brain Neoplasms/metabolism , Brain/pathology , Disease Progression , Extracellular Fluid , Agar , Aged , Brain/diagnostic imaging , Brain Neoplasms/pathology , Elasticity Imaging Techniques , Glioblastoma/pathology , Heparin , Humans , Magnetic Resonance Imaging , Male , Meningioma , Phantoms, Imaging , Soy Foods , Viscosity , Water