Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Neurointervention ; 13(2): 117-123, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30196682

ABSTRACT

PURPOSE: Wide-neck aneurysms (WNAs) associated with a dilated parent artery (PA) are not uncommon morphological abnormalities and usually cause inappropriate wall apposition and incomplete neck coverage of a tubular stent in stent-assisted coiling of aneurysms. We aimed to introduce a fusiform-shaped stent (FSS) and test its effectiveness in treating intracranial WNAs associated with a dilated PA using a three-dimensional (3D) model. MATERIALS AND METHODS: Two FSS types were designed with the middle one-third segment dilated by 10% (FSS10) and 20% (FSS20) and were compared with the tubular-shaped stent (TSS). A patient-specific 3D WNA model was prototyped and produced, and in vitro stent placement was performed. Angiographic images of the three stent types were analyzed and compared using predetermined parameters. RESULTS: The stent lumens were significantly larger in FSS10 and FSS20 than in TSS in the middle segments (P=0.046), particularly FSS20 (P=0.018). The non-covered area at the ostium tended to be smaller in FSS10 and FSS20 than in TSS, but the difference was not significant (P>0.05). The stent length was significantly longer in FSS10 and FSS20 than in TSS. The stent cell size was significantly larger in FSS than in TSS. CONCLUSION: Better vessel wall apposition and aneurysmal neck coverage was observed for FSS than for TSS. No significant difference was observed between FSS10 and FSS20.

2.
Neurointervention ; 12(1): 3-10, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28316864

ABSTRACT

PURPOSE: Onyx has been successfully applied in the treatment of various neurovascular lesions. However, some experience is required to get accustomed to its unpredictable fluoroscopic visibility during injection. This in vitro study aimed to evaluate the characteristics of radiopacity change in a simulated embolization procedure. MATERIALS AND METHODS: Using a bench-top Onyx injection experiment simulating a typical brain arteriovenous malformation embolization, nine cycles of casting modes (continuous injection) and plugging modes (injection with intermittent pauses) were performed. Radiodensity of Onyx droplets collected from the microcatheter tip and the distal head portion of the microcatheter were measured as time lapsed. Distribution of droplet radiodensity (radiodensity) and distribution of radiographic grade (grade) were analyzed and compared by repeated measurements. RESULTS: Within-group analysis revealed no significant radiodensity change with time (P>0.05). The radiodensity was significantly higher in the casting mode than in the plugging mode (P<0.01). The lateral radiograph of the microcatheter showed higher radiopacity (P<0.01) and better evenness (P<0.01) in the casting mode than in the plugging mode. A significant difference in microcatheter attenuation (both radiographic grade mean and SD; P<0.01) was noted between the two modes. Radiodensity had a significant influence on the radiopacity and radiopacity evenness of the microcatheter. CONCLUSION: The radiopacity of the Onyx can vary significantly over time because of early precipitation of tantalum powder. Radiopacity decreased significantly during plugging modes, characterized by pauses between injections.

3.
Neurointervention ; 11(1): 37-41, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26958411

ABSTRACT

PURPOSE: Day-care management of unruptured intracranial aneurysms can shorten hospital stay, reduce medical cost and improve outcome. We present the process, outcome and duration of hospital stay for the management of unruptured intracranial aneurysms via a neurointervention clinic in a single center during the past four years. MATERIALS AND METHODS: We analyzed 403 patients who were referred to Neurointervention Clinic at Asan Medical Center for aneurysm evaluation between January 1, 2011 and December 31, 2014. There were 141 (41%) diagnostic catheter angiographies, 202 (59%) neurointerventional procedures and 2 (0.6%) neurointerventional procedures followed by operation. We analyzed the process, outcome of angiography or neurointervention, and duration of hospital stay. RESULTS: There was no aneurysm in 58 patients who were reported as having an aneurysm in MRA or CTA (14 %). Among 345 patients with aneurysm, there were 283 patients with a single aneurysm (82%) and 62 patients with multiple aneurysms (n=62, 18%). Aneurysm coiling was performed in 202 patients (59%), surgical clipping in 14 patients (4%), coiling followed by clipping in 2 patients (0.6%) and no intervention was required in 127 patients (37%). The hospital stay for diagnostic angiography was less than 6 hours and the mean duration of hospital stay was 2.1 days for neurointervention. There were 4 procedure-related adverse events (2%) including 3 minor and 1 major ischemic strokes. CONCLUSION: Our study revealed that day-care management of unruptured intracranial aneurysms could be performed without an additional risk. It could enable rapid patient flow, shorten hospital stay and thus reduce hospital costs.

4.
Acta Radiol ; 57(8): 992-7, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26503958

ABSTRACT

BACKGROUND: Practical application of hemodynamic modification analysis based on computational fluid dynamics (CFD) in intracranial aneurysms is still under study. PURPOSE: To determine the clinical applicability of virtual stenting of aneurysms by comparing the simulated results with clinical outcome of real stenting. MATERIAL AND METHODS: Three-dimensional (3D) digital subtraction angiography (DSA) images were imported to a dedicated integrated prototypic CFD platform (Siemens Healthcare GmbH) which allows all necessary steps of 3D models for CFD analysis. The results of CFD simulation with virtual implantation of a stent can be visualized in the same platform for qualitative comparisons on a color-coded volume visualization window. Five small intracranial aneurysms with and without virtual stenting were analyzed and assessed on a qualitative level. Expert rating were performed for evaluating the simulated results, and comparing those to the long-term follow-up outcomes of real stenting. RESULTS: CFD simulation after virtual stenting was feasible in five differently located aneurysms and corresponded to the long-term changes of stented aneurysms by showing alteration in flow pattern. There was no significant difference (P = 0.5) between the simulated hemodynamic changes after virtual stenting and the angiographic changes after stenting in four aneurysms except one. There was good agreement regarding the assessment of the changes by two raters (kappa = 0.657). CONCLUSION: CFD analysis using patient-specific virtual stenting of the CFD platform may be used as a simple and less time-consuming test tool predicting the involution of aneurysms after stent placement by analyzing the vector visualization of the flow changes.


Subject(s)
Hemodynamics/physiology , Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/therapy , Patient-Specific Modeling , Stents , Angiography, Digital Subtraction , Cerebral Angiography , Cerebrovascular Circulation , Humans , Imaging, Three-Dimensional , Models, Cardiovascular
5.
Neurointervention ; 10(2): 82-8, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26389011

ABSTRACT

PURPOSE: Hypothesizing that the parent artery (PA) diameter of the aneurysm-neck segment is larger than those of normal segments, especially in wide-necked aneurysm cases, we conducted 3D angiographic analyses in wide-necked aneurysm cases focusing on the luminal morphologic change of the PA. MATERIALS AND METHODS: Under the approval of local IRB, we enrolled 26 patients with distal internal carotid artery (ICA) aneurysms, which were treated with stent assisted coiling. The PA diameters along the centerline were measured at 6 points with built-in software by two observers. Those 6 points were P1 and P2 proximally, P3 and P4 at the aneurysm ostium margins, and P5 and P6 distally. We performed an ANOVA test and a Bonferroni method for post hoc analyses. Linear regression analysis was performed to find any morphologic influencing factors. RESULTS: There were 20 distal ICA aneurysms out of 26 consecutive cases after exclusion. The differences in diameter at each point were statistically significant (p<0.0001). On post hoc analyses, the difference between P4 and P5 was significant both in maximum and mean PA diameters (p<0.0001 and p<0.001, respectively). Multivariate analyses failed to reveal any morphological influencing factor. CONCLUSION: PAs harboring a wide-necked aneurysm requiring stent assistance for coiling showed significant enlargement of the lumen, especially at the distal transition segment of the aneurysm ostium and the PA.

6.
J Neurointerv Surg ; 7(10): 740-3, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25165384

ABSTRACT

BACKGROUND: Simultaneous use of balloon catheters with embolic materials can cause unwanted rupture of the balloon occlusion catheters, which might cause a serious problem. Therefore, knowledge of the compatibility of occlusion balloon catheters with liquid embolic materials is important in various interventional procedures. OBJECTIVE: To determine the compatibility of occlusion balloon catheters with commonly used embolic materials in vitro. METHODS: We used three types of occlusion balloon catheters (Scepter C, Microvention, Tustin, California, USA; Hyperform, Covidien, Irvine, California, USA; and Ascent, Codman Neurovascular, Raynham, Massachusetts, USA) to test their tolerances to Lipiodol, n-butyl cyanoacrylate (NBCA; Histoacryl; B Braun, Melsungen, Germany), and dimethyl sulfoxide (DMSO) with Onyx. The balloon was inflated just as it is in an endovascular procedure, then put on a Petri dish to observe its morphological change after one drop of liquid embolic material was added using a 1 mL syringe. The presence of rupture and the time to rupture were evaluated by constant video monitoring. Additionally, we observed morphological changes of the balloon catheter surface after contact with embolic materials with a scanning electron microscope. RESULTS: Lipiodol or a 33% NBCA-Lipiodol mixture dropping onto the three types of balloon catheter resulted in ruptures of all three. All three types of balloon catheter were tolerant to NBCA and to DMSO followed by Onyx. CONCLUSIONS: Glue embolization should not be performed with all three kinds of balloon catheter on the market, but DMSO and Onyx are compatible with those balloon catheters.


Subject(s)
Antineoplastic Agents , Balloon Occlusion/standards , Brain Neoplasms/therapy , Catheters/standards , Chemoembolization, Therapeutic/standards , Dimethyl Sulfoxide , Enbucrilate , Equipment Failure , Ethiodized Oil , Hemangioma/therapy , Polyvinyls , Solvents , Balloon Occlusion/instrumentation , Balloon Occlusion/methods , Brain Neoplasms/blood supply , Chemoembolization, Therapeutic/methods , Hemangioma/blood supply , Humans , In Vitro Techniques , Male , Middle Aged
7.
Neurointervention ; 8(1): 23-8, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23515355

ABSTRACT

PURPOSE: Image-based computational models with fluid-structure interaction (FSI) can be used to perform plaque mechanical analysis in intracranial artery stenosis. We described a process in FSI study applied to symptomatic severe intracranial (M1) stenosis before and after stenting. MATERIALS AND METHODS: Reconstructed 3D angiography in STL format was transferred to Magics for smoothing of vessel surface and trimming of branch vessels and to HyperMesh for generating tetra volume mesh from triangular surface-meshed 3D angiogram. Computational analysis of blood flow in the blood vessels was performed using the commercial finite element software ADINA Ver 8.5. The distribution of wall shear stress (WSS), peak velocity and pressure was analyzed before and after intracranial stenting. RESULTS: The wall shear stress distributions from Computational fluid dynamics (CFD) simulation with rigid wall assumption as well as FSI simulation before and after stenting could be compared. The difference of WSS between rigid wall and compliant wall model both in pre- and post-stent case is only minor except at the stenosis region. These WSS values were greatly reduced after stenting to 15~20 Pa at systole and 3~5 Pa at end-diastole in CFD simulation, which are similar in FSI simulations. CONCLUSION: Our study revealed that FSI simulation before and after intracranial stenting was feasible despite of limited vessel wall dimension and could reveal change of WSS as well as flow velocity and wall pressure.

8.
Korean J Radiol ; 13(4): 412-6, 2012.
Article in English | MEDLINE | ID: mdl-22778562

ABSTRACT

OBJECTIVE: Device- or technique-related air embolism is a drawback of various neuro-endovascular procedures. Detachable aneurysm embolization coils can be sources of such air bubbles. We therefore assessed the formation of air bubbles during in vitro delivery of various detachable coils. MATERIALS AND METHODS: A closed circuit simulating a typical endovascular coiling procedure was primed with saline solution degassed by a sonification device. Thirty commercially available detachable coils (7 Axium, 4 GDCs, 5 MicroPlex, 7 Target, and 7 Trufill coils) were tested by using the standard coil flushing and delivery techniques suggested by each manufacturer. The emergence of any air bubbles was monitored with a digital microscope and the images were captured to measure total volumes of air bubbles during coil insertion and detachment and after coil pusher removal. RESULTS: Air bubbles were seen during insertion or removal of 23 of 30 coils (76.7%), with volumes ranging from 0 to 23.42 mm(3) (median: 0.16 mm(3)). Air bubbles were observed most frequently after removal of the coil pusher. Significantly larger amounts of air bubbles were observed in Target coils. CONCLUSION: Variable volumes of air bubbles are observed while delivering detachable embolization coils, particularly after removal of the coil pusher and especially with Target coils.


Subject(s)
Embolism, Air/etiology , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/instrumentation , Intracranial Embolism/etiology , In Vitro Techniques , Magnetic Resonance Imaging/methods , Microscopy , Risk Assessment , Statistics, Nonparametric
9.
Neurointervention ; 6(1): 13-6, 2011 Feb.
Article in English | MEDLINE | ID: mdl-22125742

ABSTRACT

PURPOSE: Computational flow dynamic (CFD) study has not been widely applied in intracranial artery stenosis due to requirement of high resolution in identifying the small intracranial artery. We described a process in CFD study applied to symptomatic severe intracranial (M1) stenosis before and after stenting. MATERIALS AND METHODS: Reconstructed 3D angiography in STL format was transferred to Magics (Materialise NV, Leuven, Belgium) for smoothing of vessel surface and trimming of branch vessels and to HyperMesh (Altair Engineering Inc., Auckland, New Zealand) for generating tetra volume mesh from triangular surface-meshed 3D angiogram. Computational analysis of blood flow in the blood vessels was performed using the commercial finite element software ADINA Ver 8.5 (ADINA R & D, Inc., Lebanon, MA). The distribution of wall shear stress (WSS), peak velocity and pressure in a patient was analyzed before and after intracranial stenting. RESULTS: Computer simulation of wall shear stress, flow velocity and wall pressure before and after stenting could be demonstrated three dimensionally by video mode according to flow vs. time dimension. Such flow model was well correlated with angiographic finding related to maximum degree of stenosis. Change of WSS, peak velocity and pressure at the severe stenosis was demonstrated before and after stenting. There was no WSS after stenting in case without residual stenosis. CONCLUSION: Our study revealed that CFD analysis before and after intracranial stenting was feasible despite of limited vessel wall dimension and could reveal change of WSS as well as flow velocity and wall pressure.

10.
Korean J Radiol ; 12(4): 515-8, 2011.
Article in English | MEDLINE | ID: mdl-21852914

ABSTRACT

The computational fluid dynamics methods for the limited flow rate and the small dimensions of an intracranial artery stenosis may help demonstrate the stroke mechanism in intracranial atherosclerosis. We have modeled the high wall shear stress (WSS) in a severe M1 stenosis. The high WSS in the systolic phase of the cardiac cycle was well-correlated with a thick fibrous cap atheroma with enhancement, as was determined using high-resolution plaque imaging techniques in a severe stenosis of the middle cerebral artery.


Subject(s)
Cerebral Angiography , Intracranial Arteriosclerosis/diagnosis , Magnetic Resonance Angiography , Blood Flow Velocity , Cerebrovascular Circulation , Computational Biology , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Shear Strength , Software , Systole
SELECTION OF CITATIONS
SEARCH DETAIL
...