Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cochrane Database Syst Rev ; 1: CD012991, 2020 01 14.
Article in English | MEDLINE | ID: mdl-31935047

ABSTRACT

BACKGROUND: Motor neuroprosthesis (MN) involves electrical stimulation of neural structures by miniaturized devices to allow the performance of tasks in the natural environment in which people live (home and community context), as an orthosis. In this way, daily use of these devices could act as an environmental facilitator for increasing the activities and participation of people with stroke. OBJECTIVES: To assess the effects of MN for improving independence in activities of daily living (ADL), activities involving limbs, participation scales of health-related quality of life (HRQoL), exercise capacity, balance, and adverse events in people after stroke. SEARCH METHODS: We searched the Cochrane Stroke Group Trials Register (searched 19 August 2019), the Cochrane Central Register of Controlled Trials (CENTRAL) (August 2019), MEDLINE (1946 to 16 August 2019), Embase (1980 to 19 August 2019), and five additional databases. We also searched trial registries, databases, and websites to identify additional relevant published, unpublished, and ongoing trials. SELECTION CRITERIA: Randomized controlled trials (RCTs) and randomized controlled cross-over trials comparing MN for improving activities and participation versus other assistive technology device or MN without electrical stimulus (stimulator is turned off), or no treatment, for people after stroke. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials, extracted data, and assessed risk of bias of the included studies. Any disagreements were resolved through discussion with a third review author. We contacted trialists for additional information when necessary and performed all analyses using Review Manager 5. We used GRADE to assess the certainty of the evidence. MAIN RESULTS: We included four RCTs involving a total of 831 participants who were more than three months poststroke. All RCTs were of MN that applied electrical stimuli to the peroneal nerve. All studies included conditioning protocols to adapt participants to MN use, after which participants used MN from up to eight hours per day to all-day use for ambulation in daily activities performed in the home or community context. All studies compared the use of MN versus another assistive device (ankle-foot orthosis [AFO]). There was a high risk of bias for at least one assessed domain in three of the four included studies. No studies reported outcomes related to independence in ADL. There was low-certainty evidence that AFO was more beneficial than MN on activities involving limbs such as walking speed until six months of device use (mean difference (MD) -0.05 m/s, 95% confidence interval (CI) -0.10 to -0.00; P = 0.03; 605 participants; 2 studies; I2 = 0%; low-certainty evidence); however, this difference was no longer present in our sensitivity analysis (MD -0.07 m/s, 95% CI -0.16 to 0.02; P = 0.13; 110 participants; 1 study; I2 = 0%). There was low to moderate certainty that MN was no more beneficial than AFO on activities involving limbs such as walking speed between 6 and 12 months of device use (MD 0.00 m/s, 95% CI -0.05 to 0.05; P = 0.93; 713 participants; 3 studies; I2 = 17%; low-certainty evidence), Timed Up and Go (MD 0.51 s, 95% CI -4.41 to 5.43; P = 0.84; 692 participants; 2 studies; I2 = 0%; moderate-certainty evidence), and modified Emory Functional Ambulation Profile (MD 14.77 s, 95% CI -12.52 to 42.06; P = 0.29; 605 participants; 2 studies; I2 = 0%; low-certainty evidence). There was no significant difference in walking speed when MN was delivered with surface or implantable electrodes (test for subgroup differences P = 0.09; I2 = 65.1%). For our secondary outcomes, there was very low to moderate certainty that MN was no more beneficial than another assistive device for participation scales of HRQoL (standardized mean difference 0.26, 95% CI -0.22 to 0.74; P = 0.28; 632 participants; 3 studies; I2 = 77%; very low-certainty evidence), exercise capacity (MD -9.03 m, 95% CI -26.87 to 8.81; P = 0.32; 692 participants; 2 studies; I2 = 0%; low-certainty evidence), and balance (MD -0.34, 95% CI -1.96 to 1.28; P = 0.68; 692 participants; 2 studies; I2 = 0%; moderate-certainty evidence). Although there was low- to moderate-certainty evidence that the use of MN did not increase the number of serious adverse events related to intervention (risk ratio (RR) 0.35, 95% CI 0.04 to 3.33; P = 0.36; 692 participants; 2 studies; I2 = 0%; low-certainty evidence) or number of falls (RR 1.20, 95% CI 0.92 to 1.55; P = 0.08; 802 participants; 3 studies; I2 = 33%; moderate-certainty evidence), there was low-certainty evidence that the use of MN in people after stroke may increase the risk of participants dropping out during the intervention (RR 1.48, 95% CI 1.11 to 1.97; P = 0.007; 829 participants; 4 studies; I2 = 0%). AUTHORS' CONCLUSIONS: Current evidence indicates that MN is no more beneficial than another assistive technology device for improving activities involving limbs measured by Timed Up and Go, balance (moderate-certainty evidence), activities involving limbs measured by walking speed and modified Emory Functional Ambulation Profile, exercise capacity (low-certainty evidence), and participation scale of HRQoL (very low-certainty evidence). Evidence was insufficient to estimate the effect of MN on independence in ADL. In comparison to other assistive devices, MN does not appear to increase the number of falls (moderate-certainty evidence) or serious adverse events (low-certainty evidence), but may result in a higher number of dropouts during intervention period (low-certainty evidence).


Subject(s)
Electric Stimulation Therapy/methods , Stroke Rehabilitation/methods , Activities of Daily Living , Humans , Motor Activity/physiology , Quality of Life , Randomized Controlled Trials as Topic , Recovery of Function , Stroke/therapy
2.
Respir Care ; 59(7): 1101-7, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24222704

ABSTRACT

BACKGROUND: The aim of the present study was to assess how volume-oriented incentive spirometry applied to patients after a stroke modifies the total and compartmental chest wall volume variations, including both the right and left hemithoraces, compared with controls. METHODS: Twenty poststroke patients and 20 age-matched healthy subjects were studied by optoelectronic plethysmography during spontaneous quiet breathing (QB), during incentive spirometry, and during the recovery period after incentive spirometry. RESULTS: Incentive spirometry was associated with an increased chest wall volume measured at the pulmonary rib cage, abdominal rib cage and abdominal compartment (P = .001) and under 3 conditions (P < .001). Compared with healthy control subjects, the tidal volume (VT) of the subjects with stroke was 24.7, 18.0, and 14.7% lower during QB, incentive spirometry, and postincentive spirometry, respectively. Under all 3 conditions, the contribution of the abdominal compartment to VT was greater in the stroke subjects (54.1, 43.2, and 48.9%) than in the control subjects (43.7, 40.8, and 46.1%, P = .039). In the vast majority of subjects (13/20 and 18/20 during QB and incentive spirometry, respectively), abdominal expansion precedes rib cage expansion during inspiration. Greater asymmetry between the right and left hemithoracic expansions occurred in stroke subjects compared with control subjects, but it decreased during QB (62.5%, P = .002), during incentive spirometry (19.7%), and postincentive spirometry (67.6%, P = .14). CONCLUSIONS: Incentive spirometry promotes increased expansion in all compartments of the chest wall and reduces asymmetric expansion between the right and left parts of the pulmonary rib cage; therefore, it should be considered as a tool for rehabilitation.


Subject(s)
Respiratory Mechanics/physiology , Spirometry , Stroke/physiopathology , Thoracic Wall/physiopathology , Adult , Aged , Breathing Exercises , Case-Control Studies , Female , Humans , Lung Volume Measurements , Male , Middle Aged , Motion , Plethysmography , Respiratory Muscles/physiopathology , Tidal Volume/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...