Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS Negl Trop Dis ; 18(5): e0011335, 2024 May.
Article in English | MEDLINE | ID: mdl-38805559

ABSTRACT

BACKGROUND: Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. OBJECTIVES: We asked whether high performance of an Immunochromatographic-test (ICT) could enable accurate, rapid diagnosis/treatment, establishing new, improved care-paradigms at point-of-care and clinical laboratory. METHODS: Data were obtained in 12 studies/analyses addressing: 1-feasibility/efficacy; 2-false-positives; 3-acceptability; 4-pink/black-line/all studies; 5-time/cost; 6-Quick-Information/Limit-of-detection; 7, 8-acute;-chronic; 9-epidemiology; 10-ADBio; 11,12-Commentary/Cases/Chronology. FINDINGS: ICT was compared with gold-standard or predicate-tests. Overall, ICT performance for 1093 blood/4967 sera was 99.2%/97.5% sensitive and 99.0%/99.7% specific. However, in clinical trial, FDA-cleared-predicate tests initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false-positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO REASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. CONCLUSIONS/SIGNIFICANCE: This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. TRIAL REGISTRATION: NCT04474132, https://clinicaltrials.gov/study/NCT04474132 ClinicalTrials.gov.


Subject(s)
Toxoplasmosis, Congenital , Female , Humans , Infant, Newborn , Pregnancy , Antibodies, Protozoan/blood , False Positive Reactions , Immunoglobulin M/blood , Prenatal Diagnosis/methods , Sensitivity and Specificity , Toxoplasma/immunology , Toxoplasmosis, Congenital/diagnosis , Toxoplasmosis, Congenital/prevention & control
2.
Emerg Microbes Infect ; 10(1): 1675-1682, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34165384

ABSTRACT

Point-of-care (POC) testing for Toxoplasma infection has the potential to revolutionize diagnosis and management of toxoplasmosis, especially in high-risk populations in areas with significant environmental contamination and poor health infrastructure precluding appropriate follow-up and preventing access to medical care. Toxoplasmosis is a significant public health challenge in Morocco, with a relatively heavy burden of infection and, to this point, minimal investment nationally to address this infection. Herein, we analyse the performance of a novel, low-cost rapid test using fingerstick-derived whole blood from 632 women (82 of whom were pregnant) from slums, educational centres, and from nomad groups across different geographical regions (i.e. oceanic, mountainous) of Morocco. The POC test was highly sensitive and specific from all settings. In the first group of 283 women, sera were tested by Platelia ELISA IgG and IgM along with fingerstick whole blood test. Then a matrix study with 349 women was performed in which fingerstick - POC test results and serum obtained by venipuncture contemporaneously were compared. These results show high POC test performance (Sensitivity: 96.4% [IC95 90.6-98.9%]; Specificity: 99.6% [IC95 97.3-99.9%]) and high prevalence of Toxoplasma infection among women living in rural and mountainous areas, and in urban areas with lower educational levels. The high performance of POC test confirms that it can reduce the need for venipuncture and clinical infrastructure in a low-resource setting. It can be used to efficiently perform seroprevalence determinations in large group settings across a range of demographics, and potentially expands healthcare access, thereby preventing human suffering.


Subject(s)
Point-of-Care Testing/standards , Toxoplasma/immunology , Toxoplasmosis/blood , Toxoplasmosis/diagnosis , Adolescent , Adult , Aged , Antibodies, Protozoan/blood , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Middle Aged , Morocco/epidemiology , Point-of-Care Testing/economics , Pregnancy , Prevalence , Risk Factors , Sensitivity and Specificity , Seroepidemiologic Studies , Toxoplasmosis/epidemiology , Toxoplasmosis/immunology , Toxoplasmosis, Congenital/blood , Toxoplasmosis, Congenital/diagnosis , Young Adult
3.
Clin Diagn Lab Immunol ; 10(5): 793-6, 2003 Sep.
Article in English | MEDLINE | ID: mdl-12965906

ABSTRACT

We evaluated industrially prepared Western blot strips designed to avoid the cross-reactions observed with indirect immunofluorescence and enzyme-linked immunosorbent assays used for the serodiagnosis of trichinellosis. The antigen preparations were crude extracts of Trichinella spiralis. The Western blot profile characteristic of trichinellosis was characterized by comparing 60 sera from patients infected by Trichinella to 11 sera from healthy subjects, 51 sera from patients with other proven parasitic diseases (cysticercosis, schistosomiasis, strongyloidosis, fascioliasis, toxocariasis, liver amebiasis, anisakiasis, filariasis, toxoplasmosis, hydatidosis, or malaria), and 23 sera from patients with autoantibodies. Specific 43- to 44-kDa and 64-kDa bands were obtained with all of the sera from 51 patients with acute trichinellosis, in 4 out of 9 patients at the early stages of the disease, and in only 1 control patient, who had suspected anisakiasis and in whom trichinellosis could not be ruled out by muscle biopsy.


Subject(s)
Blotting, Western , Trichinellosis/diagnosis , Animals , Blotting, Western/methods , Cross Reactions , Enzyme-Linked Immunosorbent Assay , False Positive Reactions , Fluorescent Antibody Technique , Humans , Reproducibility of Results , Sensitivity and Specificity , Trichinella spiralis
SELECTION OF CITATIONS
SEARCH DETAIL
...