Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 20640, 2023 Nov 24.
Article in English | MEDLINE | ID: mdl-38001325

ABSTRACT

The screen image synthesis (SIS) meter was originally proposed as a high-speed measurement tool, which fused the measured data from multiple sample-rotational angles to produce a whole-field measurement result. However, it suffered from stray light noise and lacked the capability of spectrum measurement. In this study, we propose an SIS system embedded with a snapshot hyperspectral technology, which was based on a dispersion image of the sparse sampling screen (SSS). When a photo was captured, it was transformed and calibrated to hyperspectral data at a specific sample-rotational angle. After the hyperspectral data in all sample-rotational angles were captured, an SIS image-fusion process was then applied to get the whole field hyperspectral data. By applying SSS to the SIS meter, we not only create a screen image synthesis hyperspectral meter but also effectively address the issue of stray-light noise. In the experiment, we analyze its correctness by comparing the hyperspectral value with a one-dimensional spectrum goniometer (ODSG). We also show the 2D color temperature coefficient distribution and compare it with the ODSG. Experimental results also demonstrate the feasibility in terms of both spectrum distribution meter and color coefficient temperature distribution meter.

2.
Sci Rep ; 6: 29452, 2016 07 11.
Article in English | MEDLINE | ID: mdl-27404383

ABSTRACT

Limited by the penetration depth, imaging of thick bio-tissues can be achieved only by epi-detection geometry. Applications based on forward-emitted signals or bidirectional illumination are restricted by lack of an opposite objective. A method for creating an opposite virtual objective inside thick media through phase conjugation was first proposed. Under forward illumination, the backward scattering light from the media was collected to generate a phase conjugate wave, which was sent back to the media and formed an inverse focusing light. Samples combined with a diffuser or a mouse skin were used as specimens. Inverse focusing was successfully demonstrated by applying holography-based optical phase conjugation with a BaTiO3. This result indicates the capability to create an opposite virtual objective inside live tissues. The proposed method is compatible with current coherent imaging and super-resolution imaging technologies. It creates a possible way for forward-emitted signals collection and bidirectional illumination in thick specimens.

3.
Opt Express ; 20(2): 1268-80, 2012 Jan 16.
Article in English | MEDLINE | ID: mdl-22274472

ABSTRACT

Light-emitting diodes are common light sources in modern lighting. The optical distribution of an LED package and the bidirectional scattering distribution function (BSDF) of diffusing optical components are important factors in lighting design. This paper proposes an innovative method of measuring both the optical distribution of LEDs and BSDF quickly. The proposed method uses a 2-D screen and a camera to capture the illumination on a screen, and acquires the whole-field optical distribution by synthesizing the images on the screen in different angles. This paper presents theoretical calculations and experimental results demonstrating the construction of the BSDF.


Subject(s)
Light , Lighting/instrumentation , Models, Theoretical , Optical Devices , Scattering, Radiation , Computer Simulation , Equipment Design , Lasers , Photography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...