Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
Add more filters










Publication year range
1.
Nat Commun ; 14(1): 7088, 2023 11 04.
Article in English | MEDLINE | ID: mdl-37925553

ABSTRACT

Electrophysiological recording technologies can provide valuable insights into the functioning of the central and peripheral nervous systems. Surface electrode arrays made of soft materials or implantable multi-electrode arrays with high electrode density have been widely utilized as neural probes. However, neither of these probe types can simultaneously achieve minimal invasiveness and robust neural signal detection. Here, we present an ultra-thin, minimally invasive neural probe (the "NeuroWeb") consisting of hexagonal boron nitride and graphene, which leverages the strengths of both surface electrode array and implantable multi-electrode array. The NeuroWeb open lattice structure with a total thickness of 100 nm demonstrates high flexibility and strong adhesion, establishing a conformal and tight interface with the uneven mouse brain surface. In vivo electrophysiological recordings show that NeuroWeb detects stable single-unit activity of neurons with high signal-to-noise ratios. Furthermore, we investigate neural interactions between the somatosensory cortex and the cerebellum using transparent dual NeuroWebs and optical stimulation, and measure the times of neural signal transmission between the brain regions depending on the pathway. Therefore, NeuroWeb can be expected to pave the way for understanding complex brain networks with optical and electrophysiological mapping of the brain.


Subject(s)
Brain , Neurons , Mice , Animals , Brain/physiology , Electrodes, Implanted , Brain Mapping , Somatosensory Cortex , Microelectrodes
2.
Nano Lett ; 23(13): 6184-6192, 2023 07 12.
Article in English | MEDLINE | ID: mdl-37338198

ABSTRACT

Spinal cord neuromodulation can restore partial to complete loss of motor functions associated with neuromotor disease and trauma. Current technologies have made substantial progress but have limitations as dorsal epidural or intraspinal devices that are either remote to ventral motor neurons or subject to surgical intervention in the spinal tissue. Here, we describe a flexible and stretchable spinal stimulator design with nanoscale thickness that can be implanted by minimally invasive injection through a polymeric catheter to target the ventral spinal space of mice. Ventrolaterally implanted devices exhibited substantially lower stimulation threshold currents and more precise recruitment of motor pools than did comparable dorsal epidural implants. Functionally relevant and novel hindlimb movements were achieved via specific stimulation patterns of the electrodes. This approach holds translational potential for improving controllable limb function following spinal cord injury or neuromotor disease.


Subject(s)
Biomimetics , Spinal Cord Injuries , Mice , Animals , Spinal Cord Injuries/therapy , Hindlimb , Electrodes
3.
Adv Sci (Weinh) ; 10(16): e2300220, 2023 06.
Article in English | MEDLINE | ID: mdl-37127888

ABSTRACT

Understanding complex neuronal networks requires monitoring long-term neuronal activity in various regions of the brain. Significant progress has been made in multisite implantations of well-designed probes, such as multisite implantation of Si-based and polymer-based probes. However, these multiprobe strategies are limited by the sizes and weights of interfaces to the multiple probes and the inability to track the activity of the same neurons and changes in neuronal activity over longer time periods. Here, a long single flexible probe that can be implanted by stitching into multiple regions of the mouse brain and subsequently transmit chronically stable neuronal signals from the multiple sites via a single low-mass interface is reported. The probe at four different sites is implemented using a glass capillary needle or two sites using an ultrathin metal needle. In vitro tests in brain-mimicking hydrogel show that multisite probe implantations achieve a high connection yield of >86%. In vivo histological images at each site of probes, implanted by stitching using either glass capillary or ultrathin metal insertion needles exhibit seamless tissue-probe interfaces with negligible chronic immune response. In addition, electrophysiology studies demonstrate the ability to track single neuron activities at every injection site with chronic stability over at least one month. Notably, the measured spike amplitudes and signal-to-noise ratios at different implantation sites show no statistically significant differences. Multisite stitching implantation of flexible electronics in the brain opens up new opportunities for both fundamental neuroscience research and electrotherapeutic applications.


Subject(s)
Brain , Electronics , Mice , Animals , Brain/physiology , Electronics/methods , Neurons/physiology , Prostheses and Implants , Needles
4.
Nat Biotechnol ; 41(5): 631-639, 2023 05.
Article in English | MEDLINE | ID: mdl-36593408

ABSTRACT

Recording transcriptional histories of a cell would enable deeper understanding of cellular developmental trajectories and responses to external perturbations. Here we describe an engineered protein fiber that incorporates diverse fluorescent marks during its growth to store a ticker tape-like history. An embedded HaloTag reporter incorporates user-supplied dyes, leading to colored stripes that map the growth of each individual fiber to wall clock time. A co-expressed eGFP tag driven by a promoter of interest records a history of transcriptional activation. High-resolution multi-spectral imaging on fixed samples reads the cellular histories, and interpolation of eGFP marks relative to HaloTag timestamps provides accurate absolute timing. We demonstrate recordings of doxycycline-induced transcription in HEK cells and cFos promoter activation in cultured neurons, with a single-cell absolute accuracy of 30-40 minutes over a 12-hour recording. The protein-based ticker tape design we present here could be generalized to achieve massively parallel single-cell recordings of diverse physiological modalities.


Subject(s)
Neurons , Proteins , Neurons/physiology , Promoter Regions, Genetic , Green Fluorescent Proteins/genetics
5.
Nano Lett ; 22(11): 4552-4559, 2022 06 08.
Article in English | MEDLINE | ID: mdl-35583378

ABSTRACT

Electrophysiological recording technologies can provide critical insight into the function of the nervous system and other biological tissues. Standard silicon-based probes have limitations, including single-sided recording sites and intrinsic instabilities due to the probe stiffness. Here, we demonstrate high-performance neural recording using double-sided three-dimensional (3D) electrodes integrated in an ultraflexible bioinspired open mesh structure, allowing electrodes to sample fully the 3D interconnected tissue of the brain. In vivo electrophysiological recording using 3D electrodes shows statistically significant increases in the number of neurons per electrode, average spike amplitudes, and signal to noise ratios in comparison to standard two-dimensional electrodes, while achieving stable detection of single-neuron activity over months. The capability of these 3D electrodes is further shown for chronic recording from retinal ganglion cells in mice. This approach opens new opportunities for a comprehensive 3D interrogation, stimulation, and understanding of the complex circuitry of the brain and other electrogenic tissues in live animals over extended time periods.


Subject(s)
Brain , Neurons , Animals , Brain/physiology , Electrodes , Electrophysiological Phenomena , Mice , Microelectrodes , Neurons/physiology , Silicon
6.
Nano Lett ; 21(7): 3184-3190, 2021 04 14.
Article in English | MEDLINE | ID: mdl-33734716

ABSTRACT

The development of a multifunctional device that achieves optogenetic neuromodulation and extracellular neural mapping is crucial for understanding neural circuits and treating brain disorders. Although various devices have been explored for this purpose, it is challenging to develop biocompatible optogenetic devices that can seamlessly interface with the brain. Herein, we present a tissue-like optoelectronic mesh with a compact interface that enables not only high spatial and temporal resolutions of optical stimulation but also the sampling of optically evoked neural activities. An in vitro experiment in hydrogel showed efficient light propagation through a freestanding SU-8 waveguide that was integrated with flexible mesh electronics. Additionally, an in vivo implantation of the tissue-like optoelectronic mesh in the brain of a live transgenic mouse enabled the sampling of optically evoked neural signals. Therefore, this multifunctional device can aid the chronic modulation of neural circuits and behavior studies for developing biological and therapeutic applications.


Subject(s)
Optogenetics , Surgical Mesh , Animals , Brain/diagnostic imaging , Electrodes, Implanted , Electronics , Mice
7.
Neuron ; 104(6): 1039-1055.e12, 2019 12 18.
Article in English | MEDLINE | ID: mdl-31784286

ABSTRACT

Neuronal types in the central nervous system differ dramatically in their resilience to injury or other insults. Here we studied the selective resilience of mouse retinal ganglion cells (RGCs) following optic nerve crush (ONC), which severs their axons and leads to death of ∼80% of RGCs within 2 weeks. To identify expression programs associated with differential resilience, we first used single-cell RNA-seq (scRNA-seq) to generate a comprehensive molecular atlas of 46 RGC types in adult retina. We then tracked their survival after ONC; characterized transcriptomic, physiological, and morphological changes that preceded degeneration; and identified genes selectively expressed by each type. Finally, using loss- and gain-of-function assays in vivo, we showed that manipulating some of these genes improved neuronal survival and axon regeneration following ONC. This study provides a systematic framework for parsing type-specific responses to injury and demonstrates that differential gene expression can be used to reveal molecular targets for intervention.


Subject(s)
Cell Survival/genetics , Nerve Regeneration/genetics , Neuroprotection/genetics , Retinal Ganglion Cells/physiology , Animals , Female , Male , Mice , Nerve Crush
8.
Nano Lett ; 19(8): 5818-5826, 2019 08 14.
Article in English | MEDLINE | ID: mdl-31361503

ABSTRACT

Polymer-based electronics with low bending stiffnesses and high flexibility, including recently reported macroporous syringe-injectable mesh electronics, have shown substantial promise for chronic studies of neural circuitry in the brains of live animals. A central challenge for exploiting these highly flexible materials for in vivo studies has centered on the development of efficient input/output (I/O) connections to an external interface with high yield, low bonding resistance, and long-term stability. Here we report a new paradigm applied to the challenging case of injectable mesh electronics that exploits the high flexibility of nanoscale thickness two-sided metal I/O pads that can deform and contact standard interface cables in high yield with long-term electrical stability. First, we describe the design and facile fabrication of two-sided metal I/O pads that allow for contact without regard to probe orientation. Second, systematic studies of the contact resistance as a function of I/O pad design and mechanical properties demonstrate the key role of the I/O pad bending stiffness in achieving low-resistance stable contacts. Additionally, computational studies provide design rules for achieving high-yield multiplexed contact interfacing in the case of angular misalignment such that adjacent channels are not shorted. Third, the in vitro measurement of 32-channel mesh electronics probes bonded to interface cables using the direct contact method shows a reproducibly high yield of electrical connectivity. Finally, in vivo experiments with 32-channel mesh electronics probes implanted in live mice demonstrate the chronic stability of the direct contact interface, enabling consistent tracking of single-unit neural activity over at least 2 months without a loss of channel recording. The direct contact interfacing methodology paves the way for scalable long-term connections of multiplexed mesh electronics neural probes for neural recording and modulation and moreover could be used to facilitate a scalable interconnection of other flexible electronics in biological studies and therapeutic applications.


Subject(s)
Electronics, Medical/instrumentation , Animals , Electrodes, Implanted , Equipment Design , Injections , Mice , Pliability , Syringes
9.
ACS Nano ; 13(6): 6431-6437, 2019 06 25.
Article in English | MEDLINE | ID: mdl-31117369

ABSTRACT

Treatment of heavy-metal pollution in both point-of-use water and industrial wastewater is critical in protecting human health and the environment. Current methods for heavy-metal treatment in both sources have limitations. For point-of-use water, current methods usually suffer from limited capacity and difficulties in spontaneously removing multiple heavy metals. For industrial wastewater, current methods greatly reduce the value of heavy metal by precipitating them as sludge which requires further treatment. Here we developed an electrochemical method that can treat both low-concentration and high-concentration heavy-metal pollution using either direct current (DC) or alternating current (AC) electrodeposition with graphene-oxide-modified carbon felt electrode (CF-GO). The graphene oxide provides a high density of surface functional groups to assist the electrodeposition. The electrodeposition method showed 2 orders of magnitude higher capacity (>29 g heavy metal for 1 g of graphene oxide) compared with traditional adsorption methods. For low levels of heavy-metal pollution in point-of-use water, DC electrodeposition with a CF-GO electrode can reduce single heavy-metal ion pollution (Cu, Cd, and Pb) as well as multiple ion mixtures to below safe water drinking levels. This method can tolerate a much wider range of heavy-metal pollution in point-of-use water than traditional adsorption methods. For high-level pollution in industrial wastewater, AC electrodeposition can recover >99.9% heavy-metal ions. By tuning the AC frequency and voltage, the electrodeposition method can further selectively recover Cu, Cd, and Pb separately, which adds values to the heavy-metal removal process.

10.
Nat Commun ; 10(1): 2067, 2019 05 06.
Article in English | MEDLINE | ID: mdl-31061393

ABSTRACT

Fast-charging and high-energy-density batteries pose significant safety concerns due to high rates of heat generation. Understanding how localized high temperatures affect the battery is critical but remains challenging, mainly due to the difficulty of probing battery internal temperature with high spatial resolution. Here we introduce a method to induce and sense localized high temperature inside a lithium battery using micro-Raman spectroscopy. We discover that temperature hotspots can induce significant lithium metal growth as compared to the surrounding lower temperature area due to the locally enhanced surface exchange current density. More importantly, localized high temperature can be one of the factors to cause battery internal shorting, which further elevates the temperature and increases the risk of thermal runaway. This work provides important insights on the effects of heterogeneous temperatures within batteries and aids the development of safer batteries, thermal management schemes, and diagnostic tools.

11.
Sci Adv ; 5(3): eaau5655, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30899782

ABSTRACT

Lithium metal-based batteries are attractive energy storage devices because of high energy density. However, uncontrolled dendrite growth and virtually infinite volume change, which cause performance fading and safety concerns, have limited their applications. Here, we demonstrate that a composite lithium metal electrode with an ion-conducting mesoscale skeleton can improve electrochemical performance by locally reducing the current density. In addition, the potential for short-circuiting is largely alleviated due to side deposition of mossy lithium on the three-dimensional electroactive surface of the composite electrode. Moreover, the electrode volume only slightly changes with the support of a rigid and stable scaffold. Therefore, this mesoscale composite electrode can cycle stably for 200 cycles with low polarization under a high areal current density up to 5 mA/cm2. Most attractively, the proposed fabrication process, which only involves simple mechanical deformation, is scalable and cost effective, providing a new strategy for developing high performance and long lifespan lithium anodes.

12.
Nano Lett ; 19(2): 1326-1335, 2019 02 13.
Article in English | MEDLINE | ID: mdl-30676759

ABSTRACT

Lithium (Li) metal has long been considered the "holy grail" of battery anode chemistry but is plagued by low efficiency and poor safety due to its high chemical reactivity and large volume fluctuation, respectively. Here we introduce a new host of wrinkled graphene cage (WGC) for Li metal. Different from recently reported amorphous carbon spheres, WGC show highly improved mechanical stability, better Li ion conductivity, and excellent solid electrolyte interphase (SEI) for continuous robust Li metal protection. At low areal capacities, Li metal is preferentially deposited inside the graphene cage. Cryogenic electron microscopy characterization shows that a uniform and stable SEI forms on the WGC surface that can shield the Li metal from direct exposure to electrolyte. With increased areal capacities, Li metal is plated densely and homogeneously into the outer pore spaces between graphene cages with no dendrite growth or volume change. As a result, a high Coulombic efficiency (CE) of ∼98.0% was achieved under 0.5 mA/cm2 and 1-10 mAh/cm2 in commercial carbonate electrolytes, and a CE of 99.1% was realized with high-concentration electrolytes under 0.5 mA/cm2 and 3 mAh/cm2. Full cells using WGC electrodes with prestored Li paired with Li iron phosphate showed greatly improved cycle lifetime. With 10 mAh/cm2 Li metal deposition, the WGC/Li composite anode was able to provide a high specific capacity of ∼2785 mAh/g. With its roll-to-roll compatible fabrication procedure, WGC serves as a highly promising material for the practical realization of Li metal anodes in next-generation high energy density secondary batteries.

13.
Nat Chem ; 11(4): 382-389, 2019 04.
Article in English | MEDLINE | ID: mdl-30664717

ABSTRACT

Developing a viable metallic lithium anode is a prerequisite for next-generation batteries. However, the low redox potential of lithium metal renders it prone to corrosion, which must be thoroughly understood for it to be used in practical energy-storage devices. Here we report a previously overlooked mechanism by which lithium deposits can corrode on a copper surface. Voids are observed in the corroded deposits and a Kirkendall-type mechanism is validated through electrochemical analysis. Although it is a long-held view that lithium corrosion in electrolytes involves direct charge-transfer through the lithium-electrolyte interphase, the corrosion observed here is found to be governed by a galvanic process between lithium and the copper substrate-a pathway largely neglected by previous battery corrosion studies. The observations are further rationalized by detailed analyses of the solid-electrolyte interphase formed on copper and lithium, where the disparities in electrolyte reduction kinetics on the two surfaces can account for the fast galvanic process.

14.
Nat Commun ; 9(1): 3656, 2018 09 07.
Article in English | MEDLINE | ID: mdl-30194431

ABSTRACT

The physiochemical properties of the solid-electrolyte interphase, primarily governed by electrolyte composition, have a profound impact on the electrochemical cycling of metallic lithium. Herein, we discover that the effect of nitrate anions on regulating lithium deposition previously known in ether-based electrolytes can be extended to carbonate-based systems, which dramatically alters the nuclei from dendritic to spherical, albeit extremely limited solubility. This is attributed to the preferential reduction of nitrate during solid-electrolyte interphase formation, and the mechanisms behind which are investigated based on the structure, ion-transport properties, and charge transfer kinetics of the modified interfacial environment. To overcome the solubility barrier, a solubility-mediated sustained-release methodology is introduced, in which nitrate nanoparticles are encapsulated in porous polymer gel and can be steadily dissolved during battery operation to maintain a high concentration at the electroplating front. As such, effective dendrite suppression and remarkably enhanced cycling stability are achieved in corrosive carbonate electrolytes.

15.
Adv Mater ; 30(35): e1802152, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30015999

ABSTRACT

Outdoor heat stress poses a serious public health threat and curtails industrial labor supply and productivity, thus adversely impacting the wellness and economy of the entire society. With climate change, there will be more intense and frequent heat waves that further present a grand challenge for sustainability. However, an efficient and economical method that can provide localized outdoor cooling of the human body without intensive energy input is lacking. Here, a novel spectrally selective nanocomposite textile for radiative outdoor cooling using zinc oxide nanoparticle-embedded polyethylene is demonstrated. By reflecting more than 90% solar irradiance and selectively transmitting out human body thermal radiation, this textile can enable simulated skin to avoid overheating by 5-13 °C compared to normal textile like cotton under peak daylight condition. Owing to its superior passive cooling capability and compatibility with large-scale production, this radiative outdoor cooling textile is promising to widely benefit the sustainability of society in many aspects spanning from health to economy.


Subject(s)
Nanocomposites , Cold Temperature , Humans , Sunlight , Textiles , Zinc Oxide
16.
Sci Adv ; 4(6): eaas9820, 2018 06.
Article in English | MEDLINE | ID: mdl-29942858

ABSTRACT

Lithium-ion batteries (LIBs) are considered to be one of the most important energy storage technologies. As the energy density of batteries increases, battery safety becomes even more critical if the energy is released unintentionally. Accidents related to fires and explosions of LIBs occur frequently worldwide. Some have caused serious threats to human life and health and have led to numerous product recalls by manufacturers. These incidents are reminders that safety is a prerequisite for batteries, and serious issues need to be resolved before the future application of high-energy battery systems. This Review aims to summarize the fundamentals of the origins of LIB safety issues and highlight recent key progress in materials design to improve LIB safety. We anticipate that this Review will inspire further improvement in battery safety, especially for emerging LIBs with high-energy density.

17.
Adv Mater ; 30(32): e1802661, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29939433

ABSTRACT

High-energy all-solid-state lithium (Li) batteries have great potential as next-generation energy-storage devices. Among all choices of electrolytes, polymer-based systems have attracted widespread attention due to their low density, low cost, and excellent processability. However, they are generally mechanically too weak to effectively suppress Li dendrites and have lower ionic conductivity for reasonable kinetics at ambient temperature. Herein, an ultrastrong reinforced composite polymer electrolyte (CPE) is successfully designed and fabricated by introducing a stiff mesoporous SiO2 aerogel as the backbone for a polymer-based electrolyte. The interconnected SiO2 aerogel not only performs as a strong backbone strengthening the whole composite, but also offers large and continuous surfaces for strong anion adsorption, which produces a highly conductive pathway across the composite. As a consequence, a high modulus of ≈0.43 GPa and high ionic conductivity of ≈0.6 mS cm-1 at 30 °C are simultaneously achieved. Furthermore, LiFePO4 -Li full cells with good cyclability and rate capability at ambient temperature are obtained. Full cells with cathode capacity up to 2.1 mAh cm-2 are also demonstrated. The aerogel-reinforced CPE represents a new design principle for solid-state electrolytes and offers opportunities for future all-solid-state Li batteries.

18.
Nano Lett ; 18(6): 3829-3838, 2018 06 13.
Article in English | MEDLINE | ID: mdl-29727578

ABSTRACT

Among all solid electrolytes, composite solid polymer electrolytes, comprised of polymer matrix and ceramic fillers, garner great interest due to the enhancement of ionic conductivity and mechanical properties derived from ceramic-polymer interactions. Here, we report a composite electrolyte with densely packed, vertically aligned, and continuous nanoscale ceramic-polymer interfaces, using surface-modified anodized aluminum oxide as the ceramic scaffold and poly(ethylene oxide) as the polymer matrix. The fast Li+ transport along the ceramic-polymer interfaces was proven experimentally for the first time, and an interfacial ionic conductivity higher than 10-3 S/cm at 0 °C was predicted. The presented composite solid electrolyte achieved an ionic conductivity as high as 5.82 × 10-4 S/cm at the electrode level. The vertically aligned interfacial structure in the composite electrolytes enables the viable application of the composite solid electrolyte with superior ionic conductivity and high hardness, allowing Li-Li cells to be cycled at a small polarization without Li dendrite penetration.

19.
Nano Lett ; 18(2): 1130-1138, 2018 02 14.
Article in English | MEDLINE | ID: mdl-29297691

ABSTRACT

Aerosol-induced haze problem has become a serious environmental concern. Filtration is widely applied to remove aerosols from gas streams. Despite classical filtration theories, the nanoscale capture and evolution of aerosols is not yet clearly understood. Here we report an in situ investigation on the nanoscale capture and evolution of aerosols on polyimide nanofibers. We discovered different capture and evolution behaviors among three types of aerosols: wetting liquid droplets, nonwetting liquid droplets, and solid particles. The wetting droplets had small contact angles and could move, coalesce, and form axisymmetric conformations on polyimide nanofibers. In contrast, the nonwetting droplets had a large contact angle on polyimide nanofibers and formed nonaxisymmetric conformations. Different from the liquid droplets, the solid particles could not move along the nanofibers and formed dendritic structures. This study provides an important insight for obtaining a deep understanding of the nanoscale capture and evolution of aerosols and benefits future design and development of advanced filters.

20.
Sci Adv ; 3(10): eaao0713, 2017 10.
Article in English | MEDLINE | ID: mdl-29062894

ABSTRACT

Solid-state lithium (Li) metal batteries are prominent among next-generation energy storage technologies due to their significantly high energy density and reduced safety risks. Previously, solid electrolytes have been intensively studied and several materials with high ionic conductivity have been identified. However, there are still at least three obstacles before making the Li metal foil-based solid-state systems viable, namely, high interfacial resistance at the Li/electrolyte interface, low areal capacity, and poor power output. The problems are addressed by incorporating a flowable interfacial layer and three-dimensional Li into the system. The flowable interfacial layer can accommodate the interfacial fluctuation and guarantee excellent adhesion at all time, whereas the three-dimensional Li significantly reduces the interfacial fluctuation from the whole electrode level (tens of micrometers) to local scale (submicrometer) and also decreases the effective current density for high-capacity and high-power operations. As a consequence, both symmetric and full-cell configurations can achieve greatly improved electrochemical performances in comparison to the conventional Li foil, which are among the best reported values in the literature. Noticeably, solid-state full cells paired with high-mass loading LiFePO4 exhibited, at 80°C, a satisfactory specific capacity even at a rate of 5 C (110 mA·hour g-1) and a capacity retention of 93.6% after 300 cycles at a current density of 3 mA cm-2 using a composite solid electrolyte middle layer. In addition, when a ceramic electrolyte middle layer was adopted, stable cycling with greatly improved capacity could even be realized at room temperature.

SELECTION OF CITATIONS
SEARCH DETAIL
...