1.
Appl Opt ; 54(35): 10425-31, 2015 Dec 10.
Article in English | MEDLINE | ID: mdl-26836866

ABSTRACT

An optical-based method is proposed for measuring the glucose concentration of samples containing scattering particles. In the proposed approach, a Stokes-Mueller reflection-based polarimetry technique is used to solve the Mueller matrices of a turbid glucose sample with circular birefringence and depolarization properties given six incident lights with different polarization states. Using an error function defined as the difference between the simulated output Stokes vectors and the experimental ones, a genetic algorithm is used to inversely derive the optical rotation and depolarization parameters of the experimental sample corresponding to the glucose concentration and scattering depolarization effect, respectively. The validity of the proposed method is demonstrated using glucose samples containing 0.02 ml and 0.04 ml lipofundin, respectively.


Subject(s)
Glucose/analysis , Algorithms , Animals , Birefringence , Humans , Models, Theoretical , Optical Phenomena , Scattering, Radiation