Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Dig Dis ; 25(3): 191-199, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38697920

ABSTRACT

OBJECTIVE: To compare the detection rate and diagnostic accuracy of cardia polyps using endoscopy with blue laser imaging (BLI) and white-light imaging (WLI). METHODS: Patients were randomly divided into the BLI group and WLI group according to the endoscopic procedures. BLI followed by WLI was conducted in the BLI group, whereas WLI followed by BLI examination was conducted in the WLI group. The number, size, microstructure, and microvascular patterns of cardia polyps detected were recorded. Biopsy of the polyps was then performed. RESULTS: The detection rate of cardia polyps in the BLI group was higher than that in the WLI group (7.87% vs 4.22%, P = 0.018). The rate of overlooked lesions in the BLI group was lower than in the WLI group (0.64% vs 3.38%, P = 0.003). The diagnostic coincidence rate between magnifying BLI and histopathology was 88.16%. The sensitivity, specificity, positive predictive value and negative predictive value for the diagnosis of neoplastic lesions by magnifying endoscopy with BLI were 90.91%, 87.69%, 55.56%, and 98.28%, respectively. The most remarkable patterns for predicting inflammatory polyps were the prolonged and fine network patterns (sensitivity 71.43%, specificity 93.75%). Small round combined with honeycomb patterns were the most common among fundic gland polyps (sensitivity 80.00%, specificity 98.48%). Neoplastic lesions presented as villous or ridge-like combined with core vascular or unclear pattern for both microvascular and microstructure patterns. CONCLUSION: BLI is more effective than WLI in the detection and diagnosis of cardia polyps, and magnifying endoscopy with BLI may help diagnose such lesions.


Subject(s)
Cardia , Feasibility Studies , Stomach Neoplasms , Humans , Female , Male , Middle Aged , Cardia/pathology , Cardia/diagnostic imaging , Adult , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/diagnosis , Stomach Neoplasms/pathology , Aged , Polyps/diagnostic imaging , Polyps/diagnosis , Gastroscopy/methods , Sensitivity and Specificity , Predictive Value of Tests , Lasers
3.
Opt Express ; 25(16): 18581-18591, 2017 Aug 07.
Article in English | MEDLINE | ID: mdl-29041056

ABSTRACT

Based on the circuit including linear optical elements, a fault-tolerant distribution of GHZ states against collective noise among three parties is proposed. Additionally, two controlled DSQC protocols using the shared GHZ states as quantum channels are also presented under the charge of the controller. The first controlled DSQC protocol applies single parity analysis based on weak cross-Kerr nonlinearities. The receiver Bob performs single-photon measurement to obtain the secret information after the outcome publication of the single parity analysis executed by the sender Alice. The second protocol applies dense coding to double information transmission capacity, and the double parity analyses based on weak cross-Kerr nonlinearities are performed to obtain the secret information.

4.
Acta Crystallogr Sect E Struct Rep Online ; 65(Pt 10): o2401, 2009 Sep 09.
Article in English | MEDLINE | ID: mdl-21577864

ABSTRACT

In the title compound, C(7)H(6)Cl(2)N(2)S, the benzene ring and the mean plane of the thio-urea fragment [-N-C(=S)-N] make a dihedral angle of 66.77 (3)°. Inter-molecular N-H⋯S and N-H⋯Cl hydrogen bonds link the mol-ecules into a three-dimensional network.

SELECTION OF CITATIONS
SEARCH DETAIL
...