Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Chem Soc ; 146(12): 8260-8268, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38497725

ABSTRACT

We report the synthesis, crystal structure, and physical properties of a novel ternary compound, Th2Cu4As5. The material crystallizes in a tetragonal structure with lattice parameters a = 4.0639(3) Å and c = 24.8221(17) Å. Its structure can be described as an alternating stacking of fluorite-type Th2As2 layers with antifluorite-type double-layered Cu4As3 slabs. The measurement of electrical resistivity, magnetic susceptibility, and specific heat reveals that Th2Cu4As5 undergoes bulk superconducting transition at 4.2 K. Additionally, all these physical quantities exhibit anomalies at 48 K, accompanied by a sign change in the Hall coefficient, suggesting a charge-density-wave-like (CDW) phase transition. Drawing from both experimental data and band calculations, we propose that the superconducting and CDW-like phase transitions are, respectively, associated with the Cu4As3 slabs and the As plane in the Th2As2 layers.

2.
BMC Infect Dis ; 23(1): 874, 2023 Dec 13.
Article in English | MEDLINE | ID: mdl-38093214

ABSTRACT

BACKGROUND: The sensitivity of HIV screening assays often leads to a high rate of false-positive results, requiring retests and confirmatory tests. This study aimed to analyze the capability of signal-to-cutoff (S/CO) ratios of HIV screening assay to predict HIV infection. METHODS: A retrospective study on the HIV screening-positive population was performed at Zhongshan Hospital, Xiamen University, the correlation between HIV screening assay S/CO ratios and HIV infection was assessed, and plotted Receiver Operating Characteristic (ROC) curves were generated to establish the optimal cutoff value for predicting HIV infection. RESULTS: Out of 396,679 patients, 836 were confirmed to be HIV-infected, with an HIV prevalence of 0.21%. The median S/CO ratios in HIV infection were significantly higher than that in non-HIV infection (296.9 vs. 2.41, P < 0.001). The rate of confirmed HIV infection was increased with higher S/CO ratios in the screening assay. The ROC curve based on the HIV screening assay S/CO ratio achieved a sensitivity of 93.78% and a specificity of 93.12% with an optimal cutoff value of 14.09. The area under the ROC curve was 0.9612. Further analysis of the ROC curve indicated that the S/CO ratio thresholds yielding positive predictive values of 99%, 99.5%, and 100% for HIV infection were 26.25, 285.7, and 354.5, respectively. CONCLUSION: Using HIV screening assay S/CO ratio to predict HIV infection can largely reduce necessitating retests and confirmatory tests. Incorporating the S/CO ratio into HIV testing algorithms can have significant implications for medical and public health practices.


Subject(s)
HIV Infections , Humans , HIV Infections/diagnosis , HIV Infections/epidemiology , Sensitivity and Specificity , Retrospective Studies , ROC Curve , HIV Testing , Mass Screening/methods
3.
Front Med (Lausanne) ; 9: 1018578, 2022.
Article in English | MEDLINE | ID: mdl-36465910

ABSTRACT

Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the causative agent of coronavirus disease 2019 (COVID-19). Serologic testing is complementary to nucleic acid screening to identify SARS-CoV-2. This study aimed to evaluate unspecific reactivity in SARS-CoV-2 serologic tests. Materials and methods: Total anti-SARS-CoV-2 antibodies from 46,777 subjects who were screened for SARS-CoV-2 were retrospectively studied to evaluate the incidence and characteristics of the unspecific reactivity. A total of 1,114 pre-pandemic samples were also analysed to compare unspecific reactivity. Results: The incidence of unspecific reactivity in anti-SARS-CoV-2 total antibody testing was 0.361% in 46,777 post-pandemic samples, similar to the incidence of 0.359% (4/1,114) in 1,114 pre-pandemic samples (p = 0.990). Subjects ≥ 19 years old had a 2.753-fold [95% confidence interval (CI), 1.130-6.706] higher probability of unspecific reactivity than subjects < 19 years old (p = 0.026). There was no significant difference between the sexes. The unspecific reactivity was associated with 14 categories within the disease spectrum, with three tops being the skin and subcutaneous tissue diseases (0.93%), respiratory system diseases (0.78%) and neoplasms diseases (0.76%). The percentage of patients with a titer ≥ 13.87 cut-off index (COI) in the unspecific reactivity was 7.69%. Conclusion: Our results suggest a unspecific reactivity incidence rate of 0.361% involving 14 categories on the disease spectrum. Unspecific reactivity needs to be excluded when performing serologic antibody testing in COVID-19 epidemiological analyses or virus tracing.

4.
Materials (Basel) ; 15(3)2022 Jan 21.
Article in English | MEDLINE | ID: mdl-35160747

ABSTRACT

We report synthesis, crystal structure, and physical properties of Sr2Cr2AsO3. The new compound crystallizes in a Sr2GaO3CuS-type structure with two distinct Cr sites, Cr(1) in the perovskite-like block layers of "Sr3Cr2O6" and Cr(2) in the ThCr2Si2-type layers of "SrCr2As2". An inter-block-layer charge transfer is explicitly evidenced, which dopes electrons in the CrO2 planes and simultaneously dopes holes into the CrAs layers. Measurements of electrical resistivity, magnetization, and specific heat, in combination with density-functional theoretical calculations, indicate that the title material is an antiferromagnetic metal. The Cr(2) magnetic moments in the CrAs layers order at 420 K, while the Cr(1) spins in the CrO2 planes show quasi-two-dimensional magnetism with long-range ordering below 80 K. Both Néel temperatures are significantly reduced, compared with those of the cousin material Sr2Cr3As2O2, probably due to the intrinsic charge-carrier doping. Complex re-entrant magnetic transitions with a huge magnetic hysteresis were observed at low temperatures.

5.
Int Immunopharmacol ; 105: 108556, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35086055

ABSTRACT

OBJECTIVE: To investigate the clinical characteristics of patients with false-positive human immunodeficiency virus (HIV) screening test results and provide a theoretical basis to interpret the results of HIV screening tests. METHODS: This retrospective study evaluated the incidence of false-positive results for HIV screening tests and characterized false-positive reactions during HIV screening in a large-scale study at Zhongshan Hospital, Xiamen University. RESULTS: False-positive HIV test results occurred for 264 of 275,263 (0.10%) serum samples. Although the incidence of a false-positive HIV screening result did not differ between male and female patients (screening χ2 = 1.194; P = 0.275), it increased with age (χ2 = 25.759; P < 0.01). False-positive reactions were associated with 16 disease categories, including 101 diseases, some of which have never been reported previously to be associated with false-positive HIV screening results. CONCLUSIONS: The occurrence of false-positive HIV screening test results may indicate underlying serious disorders. Characterization of patients with false-positive HIV screening test results can help identify potential diseases unrelated to HIV.


Subject(s)
HIV Infections , False Positive Reactions , Female , HIV Infections/diagnosis , HIV Infections/epidemiology , Humans , Male , Mass Screening/methods , Retrospective Studies
6.
Springerplus ; 5(1): 743, 2016.
Article in English | MEDLINE | ID: mdl-27376011

ABSTRACT

BACKGROUND: Chemokine ligand 13 (CXCL13) is believed to play a role in the recruitment of B cells in the central nervous system during neuroinflammation. Neurosyphilis is a group of clinical syndromes of the central nervous system caused by Treponema pallidum (T. pallidum) infection. The relationship between CXCL13 and neurosyphilis still needs further study. In our study, CSF and serum CXCL13 concentrations were detected among 40 neurosyphilis patients, 31 syphilis/non-neurosyphilis patients, 26 non-syphilis/other central nervous system diseases patients. Serum CXCL13 concentrations were detected in 49 healthy persons. All enrolled persons were HIV-negative. Receiver operating characteristic (ROC) analysis was performed to determine the threshold value that could distinguish neurosyphilis from syphilis. RESULTS: We found that the CSF CXCL13 concentrations and CXCL13 quotient (QCXCL13) were significantly increased in neurosyphilis patients compared to syphilis/non-neurosyphilis (χ(2) = 21.802, P < 0.001) and non-syphilis patients (χ(2) = 7.677, P = 0.002). ROC curve analyses revealed that CSF CXCL13 concentrations and QCXCL13 could serve as valuable biomarkers for differentiating neurosyphilis from non-neurosyphilis/syphilis. CONCLUSIONS: The CSF CXCL13 and QCXCL13 could serve as valuable biomarkers for differentiating neurosyphilis from non-neurosyphilis/syphilis in HIV-negative patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...