Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
J Clin Med ; 13(5)2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38592323

ABSTRACT

(1) Background: Transfemoral transcatheter aortic valve implantation (TAVI) has become the standard treatment for most patients with severe symptomatic aortic stenosis. Intravascular lithotripsy may facilitate transfemoral TAVI (IVL-TAVI) even in patients with severely calcified iliofemoral disease. We assessed technical aspects and clinical outcomes of this novel approach compared to alternative transaxillary access (TAX-TAVI). (2) Methods: IVL-TAVI was performed for severe iliofemoral calcifications precluding standard transfemoral access in 30 patients from 2019 to 2022 at a single academic heart center. IVL was performed as part of the TAVI procedure in all cases. Results were compared to a control group of 44 TAX-TAVI procedures performed for the same indication from 2016 to 2021. The safety outcome was a composite of all-cause death, stroke, access-related bleeding ≥ type 2 within 24 h and major vascular access site complications at 30 days. The efficacy outcome was defined as a technical success according to VARC-3. (3) Results: Median age was 78.2 [74.3, 82.6] years, 45.9% were female and mean STS-PROM was 3.6% [2.3, 6.0]. Iliofemoral calcifications were more severe in the IVL-TAVI vs. TAX-TAVI groups (lesion length: 63.0 mm [48.6, 80.3] vs. 48.5 mm [33.1, 68.8]; p = 0.043, severe calcification at target lesion: 90.0% vs. 68.2%; p = 0.047, and median arc calcification 360.0° [297.5, 360.0] vs. 360.0° [180.0, 360.0]; p = 0.033). Technical success was achieved in 93.3% vs. 81.8% (p = 0.187) in IVL- and TAX-TAVI and the safety outcome occurred in 10.0% vs. 31.8% in IVL- and TAX-TAVI (p = 0.047), respectively. (4) Conclusions: IVL-assisted transfemoral TAVI was feasible and safe with favorable outcomes compared to TAX-TAVI. IVL may further expand the number of patients eligible for transfemoral TAVI and may help overcome limitations of an alternative access.

2.
Clin Res Cardiol ; 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38466346

ABSTRACT

BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.

3.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479966

ABSTRACT

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Ischemic Stroke , Stroke , Transcatheter Aortic Valve Replacement , Humans , Ischemic Stroke/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Stroke/diagnostic imaging , Stroke/etiology , Stroke/prevention & control , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
4.
Clin Res Cardiol ; 112(5): 691-701, 2023 May.
Article in English | MEDLINE | ID: mdl-36792752

ABSTRACT

BACKGROUND: Beneficial results of transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) in patients at all risk strata have led to substantial changes in guideline recommendations for valvular heart disease. AIM: To examine influence of these guideline changes on a real-world TAVI cohort, we evaluated how risk profiles and outcomes of TAVI patients developed in our single-center patient cohort over a period of 12 years. METHODS: Baseline, procedural and 30-day outcome parameters of TAVI patients were retrospectively compared between three time periods (period 1: 2008-2012, period 2: 2013-2017, period 3: 2018-2020). RESULTS: Between 03/2008 and 12/2020, a total of 3678 patients underwent TAVI at our center. The median age was 81.1 years (25th, 75th percentile: 76.7, 84.9) with no significant change over time. The EuroSCORE II showed a continuous and significant decline from 5.3% (3.3, 8.6) in period 1 to 2.8% (1.7, 5.0) in period 3 (p < 0.001). Furthermore, rates of permanent pacemaker implantation, acute kidney injury, and paravalvular leakage ≥ moderate continuously declined over time. Accordingly, the 30-day mortality fell from 9.3% in period 1 to 4.3% in period 3 (p < 0.001). CONCLUSION: Despite substantial guideline alterations, median patient age remained largely unchanged in our TAVI cohort over the past 12 years. Therefore, increased age still appears to be the main reason to choose TAVI over SAVR. However, risk profiles declined substantially. Significant improvements in early outcomes suggest favorable influence of less invasive access routes, improved device platforms and growing user experience.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged, 80 and over , Child , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Retrospective Studies , Risk Factors , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods
5.
Clin Res Cardiol ; 112(5): 667-676, 2023 May.
Article in English | MEDLINE | ID: mdl-36656376

ABSTRACT

BACKGROUND: Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). AIM: We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. METHODS: A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. RESULTS: In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43-0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. CONCLUSION: Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hemodynamics , Ventricular Function, Left , Stroke Volume , Severity of Illness Index
6.
JACC Cardiovasc Interv ; 15(18): 1808-1819, 2022 09 26.
Article in English | MEDLINE | ID: mdl-36137683

ABSTRACT

BACKGROUND: Despite advances in transcatheter aortic valve replacement (TAVR), periprocedural acute ischemic stroke remains a concern. OBJECTIVES: The aims of this study were to investigate acute ischemic stroke complicating TAVR (AISCT) and to describe the indications and outcomes of interventions to treat AISCT. METHODS: An international multicenter registry was established focusing on AISCT within 30 days of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale. Primary outcomes were 1-year all-cause death and neurologic disability status at 90 days according to modified Rankin scale score. RESULTS: Of 16,615 TAVR procedures, 387 patients with AISCT were included (2.3%). Rates of 1-year death were 28.9%, 35.9%, and 77.5% in patients with mild, moderate, and severe stroke, respectively (P < 0.001). Although 348 patients were managed conservatively, 39 patients (10.1%) underwent neurointervention (NI) with either mechanical thrombectomy (n = 26) or thrombolytic therapy (n = 13). In a subanalysis excluding patients with mild stroke, there was no clear 1-year survival benefit for NI compared with conservative management (47.6% vs 41.1%, respectively; P = 0.78). In a logistic regression model controlling for stroke severity, NI was associated with 2.9-fold odds (95% CI: 1.2-7.0; P = 0.016) of independent survival at 90 days. CONCLUSIONS: AISCT carries significant morbidity and mortality, which is correlated with stroke severity. The present findings suggest that neurologic disability for patients with moderate or worse stroke could potentially be improved by timely intervention and highlight the importance of collaboration between cardiologists and neurologists to optimize AISCT outcomes.


Subject(s)
Aortic Valve Stenosis , Ischemic Stroke , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Postoperative Complications/etiology , Registries , Risk Factors , Stroke/diagnostic imaging , Stroke/etiology , Stroke/therapy , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
7.
Front Cardiovasc Med ; 9: 892956, 2022.
Article in English | MEDLINE | ID: mdl-35557539

ABSTRACT

Cerebrovascular events remain a serious complication in patients undergoing transcatheter aortic valve implantation with an incidence of 2-3% at 30 days. While expanding TAVI to younger low-risk patients, prevention of periprocedural strokes becomes even more important. Different cerebral embolic protection devices have been tested but a clear clinical benefit has not been demonstrated in randomized trials. Due to the multifactorial aetiology with different predisposing factors, stroke prevention should include procedural and periprocedural strategies. This article aims to summarize different approaches and discuss open questions.

8.
Am J Cardiol ; 171: 115-121, 2022 05 15.
Article in English | MEDLINE | ID: mdl-35307189

ABSTRACT

As valve-in-valve (ViV) transcatheter aortic valve implantation is still an evolving method, we evaluated the development of early and midterm outcomes after ViV and conventional redo-surgical aortic valve replacement (SAVR) over the past 2 decades. In-hospital databases were retrospectively screened for patients ≥60 years treated for failing bioprosthetic aortic valves at our center. Clinical and follow-up characteristics were compared between patients who underwent ViV or redo-SAVR according to valve academic research consortium-2 (VARC-2) definitions. The comparison of outcome parameters was adjusted for baseline differences between groups. Between June 2002 and April 2020, 209 patients with ViV and 65 redo-SAVR patients met inclusion criteria. No significant differences were found in 30 days (ViV 3.8%, SAVR 3.1%, p = 0.778) or 6-month mortality (ViV 14.0%, SAVR 7.5%, p = 0.283). As patients with ViV less frequently experienced acute kidney injury (stage II or III) and life-threatening bleeding, they more frequently reached the 30-day VARC-2 combined safety end point (79.2% vs 61.5%, odds ratio [OR] 2.540, p = 0.023). Patients with ViV less frequently reached clinical efficacy (68.3% vs 84.6%, OR 0.408, p = 0.041) and device success (79.9% vs 92.3%, OR 0.311, p = 0.040) end points, because of higher frequency of postprocedural transvalvular gradients >20 mm Hg. However, over the past decade, VARC-2 clinical efficacy and device success rates continuously increased in ViV cases. In conclusion, ViV and SAVR were associated with similar acute mortality and different beneficial and adverse outcome profiles in this single-center cohort. Results after ViV procedures have continuously improved over the past years.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Reoperation , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
9.
Am Heart J ; 247: 112-122, 2022 05.
Article in English | MEDLINE | ID: mdl-35149038

ABSTRACT

BACKGROUND: Despite continuous improvements in transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication. Randomized controlled trials failed to demonstrate a reduction in clinically apparent strokes or mortality after TAVI due to cerebral embolic protection (CEP). To identify potential targets of CEP strategies during TAVI, we evaluated affected brain regions, and temporal patterns of stroke onset in a routine clinical sample. METHODS AND RESULTS: A total of 3,164 consecutive patients treated with TAVI from 2008 to 2019 at a single center were screened for cerebrovascular events. Affected cerebral regions were determined according to clinical symptoms and brain imaging. Rates of disabling stroke and non-disabling stroke at 30 days were 2.2% and 1.4%, respectively. The frequency of all strokes decreased from 5.0% to 3.0% over time (P = .012). Patients with impaired left-ventricular function (OR 2.19), increased CHA2DS2-VASc (OR 1.39) and moderate/severe spontaneous echo contrast (OR 3.60) had a higher stroke risk. Acute symptom onset occurred during TAVI (19.4%), within 24 hours (40.3%) or later (25.0%); 98.3% of strokes were of ischemic origin. In intraprocedural strokes, 53.2% of lesions were found in locations considered protected by current CEP devices, and 37.5% of patients with intraprocedural strokes were exclusively affected in these areas. Baseline or procedural parameters were not associated with embolic distribution patterns. CONCLUSIONS: Most strokes occurred early after TAVI - but not necessarily during the procedure - and affected multiple brain regions only partially protected by current CEP devices. Efficient prevention of cerebrovascular events may require strategies beyond the TAVI procedure to minimize stroke risk and additional randomized controlled trials will be required to clarify the role of CEP in efficient stroke prevention during TAVI.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Heart Valve Prosthesis Implantation , Intracranial Embolism , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Brain/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Humans , Intracranial Embolism/epidemiology , Intracranial Embolism/etiology , Intracranial Embolism/prevention & control , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
EuroIntervention ; 17(17): e1417-e1424, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-34658340

ABSTRACT

BACKGROUND: Left ventricular outflow tract (LVOT) calcification is known to be associated with adverse outcomes after transcatheter aortic valve implantation (TAVI) in patients receiving first-generation transcatheter heart valves (THV). AIMS: The aim of the present study was to assess the prevalence of LVOT calcification as well as its impact on outcomes in a contemporary TAVI patient cohort. METHODS: This retrospective single-centre analysis includes 1,207 patients who underwent transfemoral TAVI between 2012 and 2018 and in whom adequate contrast-enhanced multislice computed tomgraphy (MSCT) imaging for quantification of LVOT calcification was available. RESULTS: Significant LVOT calcification, defined as >10 mm3, was present in 37.4% (n=451) of the patient cohort. After applying propensity score matching there was no difference between patients without (w/o; n=358) and with (w; n=358) significant LVOT calcification with respect to baseline clinical characteristics. At 30 days, the composite of all-cause mortality and non-disabling/disabling stroke occurred more often in patients w LVOT calcification compared to those w/o (4.6 vs 10.1%, p=0.008). Moreover, the composite VARC-3 endpoint of device success at 30 days was in favour of patients w/o LVOT calcification (82.2% vs 73.4%, p=0.007). According to Kaplan-Meier analysis, all-cause mortality one year after TAVI was higher in patients w vs w/o LVOT calcification (12.9 vs 21.4 %, p=0.004). CONCLUSIONS: In patients undergoing TAVI, the presence of significant LVOT calcification is common and associated with worse short-term clinical and functional outcomes as well as higher one-year mortality rates compared to patients w/o LVOT calcification.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Calcinosis/complications , Heart Valve Prosthesis/adverse effects , Humans , Multidetector Computed Tomography , Retrospective Studies , Treatment Outcome
11.
Clin Res Cardiol ; 111(12): 1313-1324, 2022 Dec.
Article in English | MEDLINE | ID: mdl-34773135

ABSTRACT

BACKGROUND: Patients with chronic hemodialysis due to end-stage renal disease (ESRD) or severely impaired kidney function (CKD) constitute a relevant share of patients undergoing trans-catheter aortic valve implantation (TAVI). However, data on specific challenges and outcomes remain limited. AIM: We aimed to characterize this patient population, evaluate clinical results and assess the significance of calcification patterns. METHODS: This retrospective single-center analysis evaluated 2,712 TAVI procedures (2012-2019) according to baseline renal function: GFR < 30 ml/min/1.73m2 (CKD; n = 210), chronic hemodialysis (ESRD; n = 119) and control (CTRL; n = 2383). Valvular and vascular calcification patterns were assessed from contrast-enhanced multi-detector computed tomography. Outcomes were evaluated in accordance with the VARC-2 definitions. RESULTS: Operative risk was higher in ESRD and CKD vs. CTRL (STS-score 8.4% and 7.6% vs. 3.9%, p < 0.001) and patients with ESRD had more severe vascular calcifications (49.1% vs. 33.9% and 29.0%, p < 0.01). Immediate procedural results were similar but non-procedure-related major/life-threatening bleeding was higher in ESRD and CKD (5.0% and 5.3% vs. 1.6%, p < 0.01). 3-year survival was impaired in patients with ESRD and CKD (33.3% and 35.3% vs. 65.4%, p < 0.001). Multivariable analysis identified ESRD (HR 1.60), CKD (HR 1.79) and vascular calcifications (HR 1.29) as predictors for 3-year and vascular calcifications (HR 1.51) for 30-day mortality. CONCLUSION: Patients with ESRD and CKD constitute a vulnerable patient group with extensive vascular calcifications. Immediate procedural results were largely unaffected by renal impairment, yielding TAVI a particularly valuable treatment option in these high-risk operative patients. Mid-term survival was determined by underlying renal disease, cardiovascular comorbidities, and vascular calcifications as a novel risk marker.


Subject(s)
Aortic Valve Stenosis , Kidney Failure, Chronic , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Vascular Calcification , Humans , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Retrospective Studies , Treatment Outcome , Transcatheter Aortic Valve Replacement/methods , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/epidemiology , Vascular Calcification/diagnostic imaging , Vascular Calcification/surgery , Risk Factors
12.
Clin Res Cardiol ; 110(12): 1957-1966, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34387736

ABSTRACT

BACKGROUND: A small aortic annulus is associated with increased risk of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI). Whether specific transcatheter heart valve (THV) designs yield superior hemodynamic performance in these small anatomies remains unclear. METHODS: Data from 8411 consecutive patients treated with TAVI from May 2012 to April 2019 at four German centers were retrospectively evaluated. A small aortic annulus was defined as multidetector computed tomography-derived annulus area < 400 mm2. TAVI was performed with a balloon-expanding intra-annular (Sapien-3, n = 288), self-expanding intra-annular (Portico, n = 110), self-expanding supra-annular (Evolut, n = 179 and Acurate-Neo, n = 428) and mechanically expanding infra-annular (Lotus, n = 64) THV according to local practice. PPM was defined as indexed effective orifice area ≤ 0.85cm2/m2. RESULTS: A small annulus was found in 1069 (12.7%) patients. PPM was detected in 38.3% overall with a higher prevalence after implantation of a balloon-expanding intra-annular or mechanically expanding infra-annular THV compared to self-expanding intra- and supra-annular THV. Multivariable analysis linked self-expanding THV (Evolut: Odds ratio [OR] 0.341, Acurate-Neo: OR 0.436, Portico: OR 0.291), postdilatation (OR 0.648) and age (OR 0.968) to lower rates of PPM, while aortic valve calcification was associated with an increased risk (OR 1.001). Paravalvular regurgitation > mild was more frequent after TAVI with self-expanding THV (p = 0.04). CONCLUSION: In this large contemporary multicenter patient population, a substantial number of patients with a small aortic anatomy were left with PPM after TAVI. Self-expanding supra- and intra-annular THV demonstrated superior hemodynamics in these patients at risk, however at the cost of higher rates of residual paravalvular regurgitation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Calcinosis/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Calcinosis/diagnosis , Female , Fluoroscopy , Humans , Male , Multidetector Computed Tomography , Prosthesis Design , Retrospective Studies , Treatment Outcome
14.
Clin Res Cardiol ; 110(12): 1939-1946, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34302190

ABSTRACT

BACKGROUND: Heyde syndrome (HS) is known as the association of severe aortic stenosis (AS) and recurrent gastrointestinal bleeding (GIB) from angiodysplasia. Data on the prevalence of HS and results after TAVI remain scarce. METHODS: 2548 consecutive patients who underwent TAVI for the treatment of AS from 2008 to 2017 were evaluated for a history of GIB and the presence of HS. The diagnosis of HS was defined as a clinical triad of severe AS, a history of recurrent GIB, and an endoscopic diagnosis of angiodysplasia. These patients (Heyde) were followed to investigate clinical outcomes, bleeding complications and the recurrence of GIB and were compared to patients with GIB unrelated to HS (Non-Heyde). RESULTS: A history of GIB prior to TAVI was detected in 190 patients (7.5%). Among them, 47 patients were diagnosed with HS (1.8%). Heyde patients required blood transfusions more frequently compared to Non-Heyde patients during index hospitalization (50.0% vs. 31.9%, p = 0.03). Recurrent GIB was detected in 39.8% of Heyde compared to 21.2% of Non-Heyde patients one year after TAVI (p = 0.03). In patients diagnosed with HS and recurrent GIB after TAVI, the rate of residual ≥ mild paravalvular leakage (PVL) was higher compared to those without recurrent bleeding (73.3% vs. 38.1%, p = 0.05). CONCLUSION: A relevant number of patients undergoing TAVI were diagnosed with HS. Recurrent GIB was detected in a significant number of Heyde patients during follow-up. A possible association with residual PVL requires further investigation to improve treatment options and outcomes in patients with HS.


Subject(s)
Angiodysplasia/epidemiology , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Gastrointestinal Hemorrhage/epidemiology , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Angiodysplasia/complications , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/complications , Female , Fluoroscopy , Follow-Up Studies , Gastrointestinal Hemorrhage/complications , Germany/epidemiology , Humans , Male , Prevalence , Retrospective Studies , Syndrome , Treatment Outcome
15.
Clin Res Cardiol ; 110(12): 1900-1911, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34156524

ABSTRACT

OBJECTIVES: This study aimed to assess the clinical outcome of the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary obstruction (BASILICA) technique in a single-center patient cohort considered at high or prohibitive risk of transcatheter aortic valve implantation (TAVI)-induced coronary obstruction. METHODS: Between October 2019 and January 2021, a total of 15 consecutive patients (age 81.0 [78.1, 84.4] years; 53.3% female; EuroSCORE II 10.6 [6.3, 14.8] %) underwent BASILICA procedure prior to TAVI at our institution. Indications for TAVI were degeneration of stented (n = 12, 80.0%) or stentless (n = 1, 6.7%) bioprosthetic aortic valves, or calcific stenosis of native aortic valves (n = 2, 13.3%), respectively. Individual risk of TAVI-induced coronary obstruction was assessed by pre-procedural computed tomography analysis. Procedural and 30-day outcomes were documented in accordance with Valve Academic Research Consortium (VARC)-2 criteria. RESULTS: BASILICA was attempted for single left coronary cusp in 12 patients (80.0%), for single right coronary cusp in 2 patients (13.3%), and for both cusps in 1 patient (6.7%), respectively. The procedure was feasible in 13 patients (86.7%) resulting in effective prevention of coronary obstruction, whilst TAVI was performed without prior successful bioprosthetic leaflet laceration in two patients (13.3%). In one of these patients (6.7%), additional chimney stenting immediately after TAVI was performed. No all-cause deaths or strokes were documented after 30 days. CONCLUSION: The BASILICA technique appears to be a feasible, safe and effective concept to avoid iatrogenic coronary artery obstruction during TAVI in both native and bioprosthetic valves of patients at high or prohibitive risk. ClinicalTrials.gov Identifier: NCT04227002 (Hamburg AoRtic Valve cOhoRt).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis/adverse effects , Coronary Occlusion/prevention & control , Heart Valve Prosthesis/adverse effects , Iatrogenic Disease/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Coronary Angiography , Coronary Occlusion/diagnosis , Coronary Vessels/diagnostic imaging , Echocardiography , Female , Fluoroscopy , Follow-Up Studies , Humans , Male , Postoperative Complications/diagnosis , Postoperative Complications/prevention & control , Prosthesis Design , Retrospective Studies , Tomography, X-Ray Computed
16.
Interact Cardiovasc Thorac Surg ; 32(3): 426-432, 2021 04 08.
Article in English | MEDLINE | ID: mdl-33831214

ABSTRACT

OBJECTIVES: We herein report a single-centre experience with the SAPIEN 3 Ultra balloon-expandable transcatheter aortic valve implantation (TAVI) system. METHODS: Between March 2019 and January 2020, a total of 79 consecutive patients received transfemoral TAVI using the SAPIEN 3 Ultra device. Data were retrospectively analysed according to updated Valve Academic Research Consortium-2 definitions. Detailed analysis of multislice computed tomography data was conducted to identify potential predictors for permanent pacemaker (PPM) implantation and residual paravalvular leakage (PVL) post TAVI. RESULTS: Device success and early safety were 97.5% (77/79) and 94.9% (75/79) with resulting transvalvular peak/mean pressure gradients of 21.1 ± 8.2/10.9 ± 4.4 and PVL >mild in 0/79 patients (0%). Mild PVL was seen in 18.9% (15/79) of cases. Thirty-day mortality was 2.5% (2/79). The Valve Academic Research Consortium-2 adjudicated clinical end points disabling stroke, acute kidney injury and myocardial infarction occurred in 1.3% (1/79), 5.1% (4/79) and 0% (0/79) of patients. Postprocedural PPM implantation was necessary in 7.6% (6/79) of patients. Multislice computed tomography analysis revealed significantly higher calcium amounts of the right coronary cusp in patients in need for postprocedural PPM implantation and a higher eccentricity index in patients with postinterventional mild PVL. CONCLUSIONS: First experience with this newly designed balloon-expandable-transcatheter heart valve demonstrates adequate 30-day outcomes and haemodynamic results with low mortality, low rates of PPM implantation and no residual PVL >mild. The herein-presented multislice computed tomography values with an elevated risk for PPM implantation and residual mild PVL may help to further improve outcomes with this particular transcatheter heart valve in TAVI procedures.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Commerce/trends , Heart Valve Prosthesis/trends , Multidetector Computed Tomography/trends , Prosthesis Design/trends , Aged , Aged, 80 and over , Commerce/methods , Female , Fluoroscopy/methods , Fluoroscopy/trends , Follow-Up Studies , Humans , Male , Multidetector Computed Tomography/methods , Prosthesis Design/methods , Retrospective Studies , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
17.
ESC Heart Fail ; 8(1): 461-470, 2021 02.
Article in English | MEDLINE | ID: mdl-33215870

ABSTRACT

AIMS: The aim of this study was to assess the prognostic value of the H2 FPEF score in patients undergoing transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) and preserved left ventricular ejection fraction (EF). METHODS AND RESULTS: In this multicentre study, a total of 832 patients from two German high-volume centres, who received TAVI for severe AS and preserved EF (≥50%), were identified for calculation of the H2 FPEF score. Patients were dichotomized according to low (0-5 points; n = 570) and high (6-9 points; n = 262) H2 FPEF scores. Kaplan-Meier and Cox regression analyses were applied to assess the prognostic impact of the H2 FPEF score. We observed a decrease in stroke volume index (-2.04 mL/m2 /point) and mean transvalvular gradients (-1.14 mmHg/point) with increasing H2 FPEF score translating into a higher prevalence of paradoxical low-flow, low-gradient AS among patients with high H2 FPEF score. One year after TAVI, the rates of all-cause (low vs. high H2 FPEF score: 8.0% vs. 19.4%, P < 0.0001) and cardiovascular (CV) mortality (1.9% vs. 9.0%, P < 0.0001) as well as the rate of CV mortality or rehospitalization for congestive heart failure (6.4% vs. 23.2%, P < 0.0001) were higher in patients with high H2 FPEF score compared with those with low H2 FPEF score. After multivariable analysis, a high H2 FPEF score remained independently predictive of all-cause mortality [hazard ratio 1.59 (1.28-2.35), P = 0.018] and CV mortality or rehospitalization for congestive heart failure [hazard ratio 2.92 (1.65-5.15), P < 0.001]. Among the H2 FPEF score variables, atrial fibrillation, pulmonary hypertension, and elevated left ventricular filling pressure were the strongest outcome predictors. CONCLUSIONS: The H2 FPEF score serves as an independent predictor of adverse CV and heart failure outcome among TAVI patients with preserved EF. A high H2 FPEF score is associated with the presence of paradoxical low-flow, low-gradient AS, the HFpEF in patients with AS. By identifying patients in advanced stages of HFpEF, the H2 FPEF score might be useful as a risk prediction tool in patients with preserved EF scheduled for TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Heart Failure/epidemiology , Humans , Prognosis , Stroke Volume , Ventricular Function, Left
18.
EuroIntervention ; 16(13): 1114-1122, 2021 01 20.
Article in English | MEDLINE | ID: mdl-32863242

ABSTRACT

AIMS: The relevance of spontaneous echo contrast (SEC) and left atrial appendage thrombus (LAAT) in patients undergoing transcatheter aortic valve implantation (TAVI) remains unclear. In this study, we aimed to assess the prevalence of SEC and LAAT and evaluate the impact on periprocedural outcome after TAVI. METHODS AND RESULTS: A total of 2,549 consecutive patients underwent TAVI between 2008 and 2017. After exclusion of cases with insufficient imaging, concomitant procedures or severe intraprocedural complications, 1,558 cases were analysed. Three groups were defined according to (pre)thrombotic formations - moderate or severe SEC (n=89), LAAT (n=53), and reference (n=1,416). The primary outcome was disabling ischaemic stroke within 24 hours. The prevalence was 4.4% for LAAT and 5.4% for moderate/severe SEC. The primary outcome occurred more frequently in patients with moderate/severe SEC (6.8%) compared to the reference (2.1%) and LAAT (1.9%) groups (p=0.020). SEC was identified as an independent risk factor for the primary outcome (OR 3.54 [95% CI: 1.30-9.61], p=0.013). LAAT was associated with an impaired unadjusted one-year survival (43.4%) compared to the SEC (27.3%) and reference groups (18.7%, p<0.001). CONCLUSIONS: SEC and LAAT were detected in a relevant number of patients undergoing TAVI. SEC may represent an important risk factor for intraprocedural stroke; increased mortality was observed in patients with LAAT.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Brain Ischemia , Stroke , Thrombosis , Transcatheter Aortic Valve Replacement , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Echocardiography, Transesophageal , Humans , Risk Factors , Stroke/epidemiology , Stroke/etiology , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects
19.
Am Heart J ; 225: 138-148, 2020 07.
Article in English | MEDLINE | ID: mdl-32502877

ABSTRACT

BACKGROUND: Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS: This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS: In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS: Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/pathology , Calcinosis/classification , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Calcinosis/diagnostic imaging , Calcinosis/pathology , Calcinosis/physiopathology , Female , Humans , Kaplan-Meier Estimate , Male , Prognosis , Retrospective Studies , Severity of Illness Index , Stroke Volume
20.
Eur J Cardiothorac Surg ; 54(4): 745-751, 2018 10 01.
Article in English | MEDLINE | ID: mdl-29617993

ABSTRACT

OBJECTIVES: As the number of transvenous lead extractions continues to increase, preprocedural protocols for this procedure must be assessed. The objective of this study was to determine whether an electrocardiogram (ECG)-triggered computed tomography (Et-CT) with three-dimensional (3D) reconstructions could aid lead extractors in choosing the optimal tools to improve procedural success and avoid complications. METHODS: In this study, 31 patients scheduled for transvenous lead extraction underwent a preprocedural Et-CT between January 2016 and May 2017. Both 3D-reconstructions and the two-dimensional files were reviewed for possible lead adhesions, calcifications, migrations or perforations. RESULTS: Mean age was 46.7 ± 14.0 years. Seventy-one percent of patients were men, and 29.0% had undergone prior cardiac surgery. Indications for extraction included infection (n = 18, 58.1%), lead dysfunction (n = 8, 25.8%), upgrade (n = 3, 9.7%), severe tricuspid regurgitation (n = 1, 3.2%) and superior vena cava occlusion (n = 1, 3.2%). Eighteen patients had an implantable cardioverter defibrillator (58.1%). Sixty-eight of 70 targeted leads were extracted with a mean of 2.2 leads per patient and an average lead age of 109.3 ± 58.7 months. Et-CT files supported transvenous lead extraction by revealing possible adhesions in 16 patients, 5 perforations and 2 venous occlusions. Lead extraction was performed using the excimer laser, mechanical tools and femoral snares. Complete procedural success was achieved in 93.5% (n = 29) of cases. Clinical success was 100%, and intraoperative mortality was 0%. CONCLUSIONS: A preprocedural Et-CT with 3D reconstructions can help to visualize lead alignment and identify abnormalities that may foreshadow procedural difficulties. A preprocedural Et-CT may therefore aid lead extractors in choosing the optimal extraction tool and strategy.


Subject(s)
Defibrillators, Implantable/adverse effects , Device Removal/methods , Electrocardiography/methods , Imaging, Three-Dimensional/methods , Pacemaker, Artificial/adverse effects , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Catheterization, Peripheral/methods , Equipment Failure , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/prevention & control , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...