Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Semin Nucl Med ; 54(1): 141-149, 2024 01.
Article in English | MEDLINE | ID: mdl-37357026

ABSTRACT

Prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) has emerged as an important imaging technique for prostate cancer. The use of PSMA PET/CT is rapidly increasing, while the number of nuclear medicine physicians and radiologists to interpret these scans is limited. Additionally, there is variability in interpretation among readers. Artificial intelligence techniques, including traditional machine learning and deep learning algorithms, are being used to address these challenges and provide additional insights from the images. The aim of this scoping review was to summarize the available research on the development and applications of AI in PSMA PET/CT for prostate cancer imaging. A systematic literature search was performed in PubMed, Embase and Cinahl according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A total of 26 publications were included in the synthesis. The included studies focus on different aspects of artificial intelligence in PSMA PET/CT, including detection of primary tumor, local recurrence and metastatic lesions, lesion classification, tumor quantification and prediction/prognostication. Several studies show similar performances of artificial intelligence algorithms compared to human interpretation. Few artificial intelligence tools are approved for use in clinical practice. Major limitations include the lack of external validation and prospective design. Demonstrating the clinical impact and utility of artificial intelligence tools is crucial for their adoption in healthcare settings. To take the next step towards a clinically valuable artificial intelligence tool that provides quantitative data, independent validation studies are needed across institutions and equipment to ensure robustness.


Subject(s)
Prostate , Prostatic Neoplasms , Male , Humans , Prostate/pathology , Positron Emission Tomography Computed Tomography/methods , Artificial Intelligence , Gallium Radioisotopes , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology
2.
Eur J Nucl Med Mol Imaging ; 50(5): 1510-1520, 2023 04.
Article in English | MEDLINE | ID: mdl-36650356

ABSTRACT

PURPOSE: Consistent assessment of bone metastases is crucial for patient management and clinical trials in prostate cancer (PCa). We aimed to develop a fully automated convolutional neural network (CNN)-based model for calculating PET/CT skeletal tumor burden in patients with PCa. METHODS: A total of 168 patients from three centers were divided into training, validation, and test groups. Manual annotations of skeletal lesions in [18F]fluoride PET/CT scans were used to train a CNN. The AI model was evaluated in 26 patients and compared to segmentations by physicians and to a SUV 15 threshold. PET index representing the percentage of skeletal volume taken up by lesions was estimated. RESULTS: There was no case in which all readers agreed on prevalence of lesions that the AI model failed to detect. PET index by the AI model correlated moderately strong to physician PET index (mean r = 0.69). Threshold PET index correlated fairly with physician PET index (mean r = 0.49). The sensitivity for lesion detection was 65-76% for AI, 68-91% for physicians, and 44-51% for threshold depending on which physician was considered reference. CONCLUSION: It was possible to develop an AI-based model for automated assessment of PET/CT skeletal tumor burden. The model's performance was superior to using a threshold and provides fully automated calculation of whole-body skeletal tumor burden. It could be further developed to apply to different radiotracers. Objective scan evaluation is a first step toward developing a PET/CT imaging biomarker for PCa skeletal metastases.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Male , Humans , Positron Emission Tomography Computed Tomography/methods , Artificial Intelligence , Tumor Burden , Prostatic Neoplasms/diagnostic imaging , Positron-Emission Tomography
3.
Eur J Radiol ; 113: 89-95, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30927965

ABSTRACT

PURPOSE: The aim of this study was to develop a deep learning-based method for segmentation of bones in CT scans and test its accuracy compared to manual delineation, as a first step in the creation of an automated PET/CT-based method for quantifying skeletal tumour burden. METHODS: Convolutional neural networks (CNNs) were trained to segment 49 bones using manual segmentations from 100 CT scans. After training, the CNN-based segmentation method was tested on 46 patients with prostate cancer, who had undergone 18F-choline-PET/CT and 18F-NaF PET/CT less than three weeks apart. Bone volumes were calculated from the segmentations. The network's performance was compared with manual segmentations of five bones made by an experienced physician. Accuracy of the spatial overlap between automated CNN-based and manual segmentations of these five bones was assessed using the Sørensen-Dice index (SDI). Reproducibility was evaluated applying the Bland-Altman method. RESULTS: The median (SD) volumes of the five selected bones were by CNN and manual segmentation: Th7 41 (3.8) and 36 (5.1), L3 76 (13) and 75 (9.2), sacrum 284 (40) and 283 (26), 7th rib 33 (3.9) and 31 (4.8), sternum 80 (11) and 72 (9.2), respectively. Median SDIs were 0.86 (Th7), 0.85 (L3), 0.88 (sacrum), 0.84 (7th rib) and 0.83 (sternum). The intraobserver volume difference was less with CNN-based than manual approach: Th7 2% and 14%, L3 7% and 8%, sacrum 1% and 3%, 7th rib 1% and 6%, sternum 3% and 5%, respectively. The average volume difference measured as ratio volume difference/mean volume between the two CNN-based segmentations was 5-6% for the vertebral column and ribs and ≤3% for other bones. CONCLUSION: The new deep learning-based method for automated segmentation of bones in CT scans provided highly accurate bone volumes in a fast and automated way and, thus, appears to be a valuable first step in the development of a clinical useful processing procedure providing reliable skeletal segmentation as a key part of quantification of skeletal metastases.


Subject(s)
Bone Neoplasms/diagnostic imaging , Prostatic Neoplasms, Castration-Resistant , Adult , Aged , Aged, 80 and over , Anatomic Landmarks , Bone Neoplasms/secondary , Deep Learning , Female , Humans , Male , Middle Aged , Neural Networks, Computer , Observer Variation , Positron Emission Tomography Computed Tomography/methods , Reproducibility of Results , Tomography, X-Ray Computed , Tumor Burden
4.
EJNMMI Res ; 7(1): 15, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28210997

ABSTRACT

BACKGROUND: Sodium fluoride (NaF) positron emission tomography combined with computer tomography (PET/CT) has shown to be more sensitive than the whole-body bone scan in the detection of skeletal uptake due to metastases in prostate cancer. We aimed to calculate a 3D index for NaF PET/CT and investigate its correlation to the bone scan index (BSI) and overall survival (OS) in a group of patients with prostate cancer. METHODS: NaF PET/CT and bone scans were studied in 48 patients with prostate cancer. Automated segmentation of the thoracic and lumbar spines, sacrum, pelvis, ribs, scapulae, clavicles, and sternum were made in the CT images. Hotspots in the PET images were selected using both a manual and an automated method. The volume of each hotspot localized in the skeleton in the corresponding CT image was calculated. Two PET/CT indices, based on manual (manual PET index) and automatic segmenting using a threshold of SUV 15 (automated PET15 index), were calculated by dividing the sum of all hotspot volumes with the volume of all segmented bones. BSI values were obtained using a software for automated calculations. RESULTS: BSI, manual PET index, and automated PET15 index were all significantly associated with OS and concordance indices were 0.68, 0.69, and 0.70, respectively. The median BSI was 0.39 and patients with a BSI >0.39 had a significantly shorter median survival time than patients with a BSI <0.39 (2.3 years vs not reached after 5 years of follow-up [p = 0.01]). The median manual PET index was 0.53 and patients with a manual PET index >0.53 had a significantly shorter median survival time than patients with a manual PET index <0.53 (2.5 years vs not reached after 5 years of follow-up [p < 0.001]). The median automated PET15 index was 0.11 and patients with an automated PET15 index >0.11 had a significantly shorter median survival time than patients with an automated PET15 index <0.11 (2.3 years vs not reached after 5 years of follow-up [p < 0.001]). CONCLUSIONS: PET/CT indices based on NaF PET/CT are correlated to BSI and significantly associated with overall survival in patients with prostate cancer.

SELECTION OF CITATIONS
SEARCH DETAIL
...