Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Thromb J ; 21(1): 23, 2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36864467

ABSTRACT

BACKGROUND: The use of viscoelastic tests is becoming increasingly popular. There is a paucity of validation of the reproducibility of varying coagulation states. Therefore, we aimed to study the coefficient of variation (CV) for the ROTEM EXTEM parameters clotting time (CT), clot formation time (CFT), alpha-angle and maximum clot firmness (MCF) in blood with varying degrees of coagulation strength. The hypothesis was that CV increases in states of hypocoagulability. METHODS: Critically ill patients and patients subjected to neurosurgery at a university hospital during three separate periods were included. Each blood sample was tested in eight parallel channels, yielding the CVs for the tested variables. In 25 patients, the blood samples were analysed both at baseline and after dilution with albumin 5%, as well as after being spiked with fibrinogen, simulating weak and strong coagulation. RESULTS: In total, 225 unique blood samples were collected from 91 patients. All samples were analysed in eight parallel ROTEM channels, resulting in 1,800 measurements. In hypocoagulable samples, defined as those with values outside the normal reference range, the CV of CT was higher (median (interquartile range)) (6.3% (5.1-9.5)) than for normocoagulable samples (5.1% (3.6-7.5)), p < 0.001. CFT showed no difference (p = 0.14), while the CV of alpha-angle was higher in hypocoagulable samples (3.6% (2.5-4.6)) than in normocoagulable samples (1.1% (0.8-1.6), p < 0.001. The CV of MCF was higher in hypocoagulable samples (1.8% (1.3-2.6)) than in normocoagulable samples (1.2% (0.9-1.7)), p < 0.001. The CV ranges for the different variables were as follows: CT: 1.2%-37%, CFT: 1.7%-30%, alpha-angle: 0.0%-17% and MCF: 0.0%-8.1%. CONCLUSIONS: CVs for the EXTEM ROTEM parameters CT, alpha-angle, and MCF increased in hypocoagulable blood compared to blood with normal coagulation, confirming the hypothesis for CT, alpha-angle, and MCF but not for CFT. Furthermore, the CVs for CT and CFT were much higher than those for alpha-angle and MCF. The results demonstrate that EXTEM ROTEM results from patients with weak coagulation should be interpreted with the notion of limited precision and that procoagulative treatment, based only on ROTEM EXTEM, should be given with some caution.

2.
Nanotechnology ; 19(49): 495302, 2008 Dec 10.
Article in English | MEDLINE | ID: mdl-21730666

ABSTRACT

Porous high surface area thin films of nanosheet-shaped monoclinic MoO(3) were deposited onto platinized Si substrates using patch antenna-based atmospheric microplasma processing. The films were characterized by high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM) and electrochemical analysis. The electrochemical analysis shows original redox peaks and high charge capacity, and also indicates a reversible electrochemical behaviour particularly beneficial for applications in Li-ion batteries. SEM shows that the films are highly porous and consist of nanosheets 50-100 nm thick with surface dimensions in the micrometre range. HRTEM reveals that the MoO(3) nanosheets consist of the monoclinic beta phase of MoO(3). These intricate nanoarchitectures made of monoclinic MoO(3) nanosheets have not been studied previously in the context of applications in Li-ion batteries and show superior structural and morphological features that enable effective insertion of Li ions.

SELECTION OF CITATIONS
SEARCH DETAIL
...