Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Am J Kidney Dis ; 76(1): 82-89, 2020 07.
Article in English | MEDLINE | ID: mdl-32151430

ABSTRACT

RATIONALE & OBJECTIVE: Compared with conventional (rope-ladder cannulation [RLC]) methods, use of buttonhole cannulation (BHC) to access arteriovenous fistulas (AVFs) may be associated with increased risk for bloodstream infection and other vascular access-related infection. We used national surveillance data to evaluate the infection burden and risk among in-center hemodialysis patients with AVFs using BHC. STUDY DESIGN: Descriptive analysis of infections and related events and retrospective observational cohort study using National Healthcare Safety Network (NHSN) surveillance data. SETTING & PARTICIPANTS: US patients receiving hemodialysis treated in outpatient dialysis centers. PREDICTORS: AVF cannulation methods, dialysis facility characteristics, and infection control practices. OUTCOMES: Access-related bloodstream infection; local access-site infection; intravenous (IV) antimicrobial start. ANALYTIC APPROACH: Description of frequency and rate of infections; adjusted relative risk (aRR) for infection with BHC versus RLC estimated using Poisson regression. RESULTS: During 2013 to 2014, there were 2,466 access-related bloodstream infections, 3,169 local access-site infections, and 13,726 IV antimicrobial starts among patients accessed using BHC. Staphylococcus aureus was the most common pathogen, present in half (52%) of the BHC access-related bloodstream infections. Hospitalization was frequent among BHC access-related bloodstream infections (37%). In 2014, 9% (n=271,980) of all AVF patient-months reported to NHSN were associated with BHC. After adjusting for facility characteristics and practices, BHC was associated with significantly higher risk for access-related bloodstream infection (aRR, 2.6; 95% CI, 2.4-2.8) and local access-site infection (aRR, 1.5; 95% CI, 1.4-1.6) than RLC, but was not associated with increased risk for IV antimicrobial start. LIMITATIONS: Data for facility practices were self-reported and not patient specific. CONCLUSIONS: BHC was associated with higher risk for vascular access-related infection than RLC among in-center hemodialysis patients. Decisions regarding the use of BHC in dialysis centers should take into account the higher risk for infection. Studies are needed to evaluate infection control measures that may reduce infections related to BHC.


Subject(s)
Catheter-Related Infections/epidemiology , Catheterization/adverse effects , Centers for Disease Control and Prevention, U.S. , Renal Dialysis/adverse effects , Vascular Access Devices/adverse effects , Vascular Access Devices/microbiology , Aged , Catheter-Related Infections/diagnosis , Centers for Disease Control and Prevention, U.S./statistics & numerical data , Cohort Studies , Data Analysis , Female , Humans , Kidney Failure, Chronic/epidemiology , Kidney Failure, Chronic/therapy , Male , Middle Aged , Renal Dialysis/instrumentation , Retrospective Studies , Risk Factors , United States/epidemiology
2.
Clin J Am Soc Nephrol ; 12(7): 1139-1146, 2017 Jul 07.
Article in English | MEDLINE | ID: mdl-28663227

ABSTRACT

BACKGROUND AND OBJECTIVES: Persons receiving outpatient hemodialysis are at risk for bloodstream and vascular access infections. The Centers for Disease Control and Prevention conducts surveillance for these infections through the National Healthcare Safety Network. We summarize 2014 data submitted to National Healthcare Safety Network Dialysis Event Surveillance. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Dialysis facilities report three types of dialysis events (bloodstream infections; intravenous antimicrobial starts; and pus, redness, or increased swelling at the hemodialysis vascular access site). Denominator data consist of the number of hemodialysis outpatients treated at the facility during the first 2 working days of each month. We calculated dialysis event rates stratified by vascular access type (e.g., arteriovenous fistula, arteriovenous graft, or central venous catheter) and standardized infection ratios (comparing individual facility observed with predicted numbers of infections) for bloodstream infections. We described pathogens identified among bloodstream infections. RESULTS: A total of 6005 outpatient hemodialysis facilities reported dialysis event data for 2014 to the National Healthcare Safety Network. These facilities reported 160,971 dialysis events, including 29,516 bloodstream infections, 149,722 intravenous antimicrobial starts, and 38,310 pus, redness, or increased swelling at the hemodialysis vascular access site events; 22,576 (76.5%) bloodstream infections were considered vascular access related. Most bloodstream infections (63.0%) and access-related bloodstream infections (69.8%) occurred in patients with a central venous catheter. The rate of bloodstream infections per 100 patient-months was 0.64 (0.26 for arteriovenous fistula, 0.39 for arteriovenous graft, and 2.16 for central venous catheter). Other dialysis event rates were also highest among patients with a central venous catheter. Facility bloodstream infection standardized infection ratio distribution was positively skewed with a median of 0.84. Staphylococcus aureus was the most commonly isolated bloodstream infection pathogen (30.6%), and 39.5% of S. aureus isolates tested were resistant to methicillin. CONCLUSIONS: The 2014 National Healthcare Safety Network Dialysis Event data represent nearly all United States outpatient dialysis facilities. Rates of infection and other dialysis events were highest among patients with a central venous catheter compared with other vascular access types. Surveillance data can help define the epidemiology of important infections in this patient population.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis/adverse effects , Catheter-Related Infections/epidemiology , Catheterization, Central Venous/adverse effects , Central Venous Catheters/adverse effects , Prosthesis-Related Infections/epidemiology , Renal Dialysis/adverse effects , Staphylococcal Infections/epidemiology , Administration, Intravenous , Ambulatory Care , Anti-Infective Agents/administration & dosage , Arteriovenous Shunt, Surgical/instrumentation , Bacteremia/epidemiology , Bacteremia/microbiology , Blood Vessel Prosthesis Implantation/instrumentation , Catheter-Related Infections/diagnosis , Catheter-Related Infections/drug therapy , Catheter-Related Infections/microbiology , Catheterization, Central Venous/instrumentation , Humans , Methicillin Resistance , Methicillin-Resistant Staphylococcus aureus/isolation & purification , Population Surveillance , Prognosis , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/microbiology , Quality Indicators, Health Care , Risk Factors , Staphylococcal Infections/diagnosis , Staphylococcal Infections/drug therapy , Staphylococcal Infections/microbiology , Time Factors , United States/epidemiology
3.
Infect Control Hosp Epidemiol ; 37(7): 863-6, 2016 07.
Article in English | MEDLINE | ID: mdl-26868605

ABSTRACT

Among dialysis facilities participating in a bloodstream infection (BSI) prevention collaborative, access-related BSI incidence rate improvements observed immediately following implementation of a bundle of BSI prevention interventions were sustained for up to 4 years. Overall, BSI incidence remained unchanged from baseline in the current analysis. Infect Control Hosp Epidemiol 2016;37:863-866.


Subject(s)
Cross Infection/prevention & control , Renal Dialysis/adverse effects , Sepsis/prevention & control , Ambulatory Care/methods , Ambulatory Care/statistics & numerical data , Cross Infection/epidemiology , Humans , Interinstitutional Relations , Patient Care Bundles , Renal Dialysis/methods , Sepsis/epidemiology
4.
Infect Control Hosp Epidemiol ; 37(2): 205-7, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26554448

ABSTRACT

Reports of bloodstream infections caused by methicillin-resistant Staphylococcus aureus among chronic hemodialysis patients to 2 Centers for Disease Control and Prevention surveillance systems (National Healthcare Safety Network Dialysis Event and Emerging Infections Program) were compared to evaluate completeness of reporting. Many methicillin-resistant S. aureus bloodstream infections identified in hospitals were not reported to National Healthcare Safety Network Dialysis Event.


Subject(s)
Bacteremia/epidemiology , Bacteremia/microbiology , Guideline Adherence/statistics & numerical data , Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections/epidemiology , Ambulatory Care Facilities , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Centers for Disease Control and Prevention, U.S. , Cross Infection/epidemiology , Cross Infection/microbiology , Humans , Methicillin-Resistant Staphylococcus aureus/isolation & purification , Outpatients , Renal Dialysis , Sentinel Surveillance , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...