Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Vet Intern Med ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38877661

ABSTRACT

BACKGROUND: Rate control (RC; meanHRHolter ≤ 125 bpm) increases survival in dogs with atrial fibrillation (AF). The mechanisms remain unclear. HYPOTHESIS/OBJECTIVES: Investigate echocardiographic and biomarker differences between RC and non-RC (NRC) dogs. Determine if changes post-anti-arrhythmic drugs (AAD) predict successful RC in subsequent Holter monitoring. Evaluate if early vs late RC affects survival. ANIMALS: Fifty-two dogs with AF. METHODS: Holter-derived mean heart rate, echocardiographic and biomarker variables from dogs receiving AAD were analyzed prospectively at each re-evaluation and grouped into RC or NRC. The primary endpoint was successful RC. Between group comparisons of absolute values, magnitude of change from admission to re-evaluations and end of study were performed using Mann-Whitney tests or unpaired t-tests. Logistic regression explored variables associated with inability to achieve RC at subsequent visits. Kaplan-Meier survival analysis was used to compare survival time of early vs late RC. RESULTS: At visit 2, 11/52 dogs were RC; at visit 3, 14/52 were RC; and at visit 4, 4/52 were RC. At the end of study, 25/52 remained NRC. At visit 2, both groups had increased cardiac dimensions, but NRC dogs had larger dimensions; biomarkers did not differ. At the end of study, RC showed decreased cardiac dimensions and end-terminal pro-brain natriuretic peptide (NT-proBNP) compared with NRC. No variables were useful at predicting RC success in subsequent visits. Survival analysis found no differences between early vs late RC. CONCLUSIONS AND CLINICAL IMPORTANCE: The RC dogs had decreased cardiac dimensions and NT-proBNP, suggesting HR-mediated reverse-remodeling might benefit survival, even with delayed RC achievement. Pursuit of RC is crucial despite initial failures.

2.
J Vet Intern Med ; 37(3): 887-899, 2023.
Article in English | MEDLINE | ID: mdl-37128174

ABSTRACT

BACKGROUND: The optimal heart rate (HR) in dogs with atrial fibrillation (AF) is unknown. Impact of HR on survival needs elucidation. HYPOTHESIS/OBJECTIVES: Dogs with a 24 hours Holter-derived meanHR ≤125 beats per minute (bpm; rate controlled) survive longer than dogs with higher meanHR. We further aimed to determine which variables predict ability to achieving rate control. ANIMALS: Sixty dogs with AF. METHODS: Holter-derived meanHR, clinical, echocardiographic, and biomarker variables were analyzed prospectively. Survival was recorded from time of rate control, with all-cause mortality as primary endpoint. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR ≤125 bpm vs >125 bpm. Logistic regression explored baseline variables associated with inability to achieve rate control. RESULTS: Structural heart disease was present in 56/60 dogs, 50/60 had congestive heart failure, and 45/60 died. Median time to all-cause death was 160 days (range, 88-303 days), dogs with meanHR >125 bpm (n = 27) lived 33 days (95% confidence interval [CI], 15-141 days), dogs with meanHR ≤125 bpm (n = 33) lived 608 days (95% CI, 155-880 days; P < .0001). Congenital heart disease and N-terminal pro-B-type natriuretic peptide were independently associated with higher risk of death (P < .01 and <.0001, respectively) whereas meanHR ≤125 bpm decreased the risk of death (P < .001). Increased left atrial size, increased C-reactive protein concentration and lower blood pressure at admission were associated with failure to achieve rate control. CONCLUSIONS AND CLINICAL IMPORTANCE: Rate control affects survival; an optimal target meanHR <125 bpm should be sought in dogs with AF. Baseline patient variables can help predict if rate control is achievable.


Subject(s)
Atrial Fibrillation , Dog Diseases , Heart Failure , Dogs , Animals , Atrial Fibrillation/veterinary , Prognosis , Heart Rate , Heart Failure/complications , Heart Failure/veterinary , Biomarkers
3.
J Vet Cardiol ; 18(1): 47-56, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26683157

ABSTRACT

BACKGROUND: Cardiac masses are uncommon in the canine population. When present, an attempt should be made to obtain a definitive diagnosis. Our goal with this case series was to report that as long as anatomic location permits, obtaining fine needle aspirates (FNAs) for cytological evaluation is practical, safe, and may provide a definitive diagnosis. METHODS: Our database has been retrospectively searched for cases where FNA of cardiac masses have been performed. RESULTS: A total of six cases were retrieved. Four dogs were under general anaesthesia and two were sedated. Ultrasound guided transthoracic FNAs were obtained in all cases with only minor complications: mild self-limiting pericardial effusion (n = 1) and one ventricular ectopic complex (n = 1). All dogs were closely monitored during the procedure (pulse oximetry, electrocardiography and blood pressure). A diagnosis was obtained in all cases: inflammation (n = 1), haemangiosarcoma (n = 2), sarcoma (n = 2) and chemodectoma (n = 1). CONCLUSION: A cytological diagnosis allows clinicians to make appropriate clinical decisions, has dramatic impact on treatment recommendations and gives information about prognosis.


Subject(s)
Biopsy, Fine-Needle/veterinary , Dog Diseases/pathology , Heart Neoplasms/veterinary , Myocardium/ultrastructure , Ultrasonography, Interventional/veterinary , Animals , Biopsy, Fine-Needle/methods , Dog Diseases/diagnostic imaging , Dogs , Female , Heart Neoplasms/pathology , Male
4.
J Vet Cardiol ; 15(1): 51-6, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23434245

ABSTRACT

OBJECTIVE: To characterize the electrocardiogram (ECG) of anesthetized adult emus (Dromaius novaehollandiae). ANIMALS: Ten clinically healthy adult emus anesthetised for routine physical examination and an electrocardiogram, for both monitoring and investigation into any evidence of cardiac disease. METHODS: The ECGs for each emu were obtained in right lateral recumbency, using a modified electrode placement that replicated the standard bipolar leads used in small mammals. Lead II was used for waveform analysis. RESULTS: Median P wave amplitude was 0.55 mV (range: 0.2-0.92 mV) and P wave duration was 0.06 s (0.04-0.09 s). S wave amplitude measured 1.42 mV (0.92-2.12 mV), T wave amplitude 0.67 mV (0.16-0.83 mV) and QRS duration was 0.07 s (0.07-0.12 s). Ninety percent of the QRS complexes were of rS type. CONCLUSION: Our study provides electrocardiographic baseline data for anesthetized adult emus.


Subject(s)
Dromaiidae/physiology , Electrocardiography/veterinary , Heart/physiology , Animals , Heart Rate/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...