Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Spine (Phila Pa 1976) ; 38(2): E84-93, 2013 Jan 15.
Article in English | MEDLINE | ID: mdl-23132537

ABSTRACT

STUDY DESIGN: A biomechanical study of facet joint pressure after total disc replacement using cadaveric human cervical spines during lateral bending and axial torsion. OBJECTIVE: The goal was to measure the contact pressure in the facet joint in cadaveric human cervical spines subjected to physiologic lateral bending and axial torsion before and after implantation of a ProDisc-C implant. SUMMARY OF BACKGROUND DATA: Changes in facet biomechanics can damage the articular cartilage in the joint, potentially leading to degeneration and painful arthritis. Few cadaveric and computational studies have evaluated the changes in facet joint loading during spinal loading with an artificial disc implanted. Computational models have predicted that the design and placement of the implant influence facet joint loading, but limited cadaveric studies document changes in facet forces and pressures during nonsagittal bending after implantation of a ProDisc. As such, little is known about the local facet joint mechanics for these complicated loading scenarios in the cervical spine. METHODS: Seven osteoligamentous C2-T1 cadaveric cervical spines were instrumented with a transducer to measure the C5-C6 facet pressure profiles during physiological lateral bending and axial torsion, before and after implantation of a ProDisc-C at that level. Rotations at that level and global cervical spine motions and loads were also quantified. RESULT.: Global and segmental rotations were not altered by the disc implantation. Facet contact pressure increased after implantation during ipsilateral lateral bending and contralateral torsion, but that increase was not significant compared with the intact condition. CONCLUSION: Implantation of a ProDisc-C does not significantly modify the kinematics and facet pressure at the index level in cadaveric specimens during lateral bending and axial torsion. However, changes in facet contact pressures after disc arthroplasty may have long-term effects on spinal loading and cartilage degeneration and should be monitored in vivo.


Subject(s)
Intervertebral Disc Degeneration/surgery , Intervertebral Disc/surgery , Minimally Invasive Surgical Procedures/methods , Spine/surgery , Total Disc Replacement/methods , Zygapophyseal Joint/physiology , Adult , Aged , Cadaver , Cervical Vertebrae/surgery , Humans , Male , Middle Aged , Pressure , Spine/physiopathology , Torque
2.
Spine J ; 12(10): 949-59, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22975463

ABSTRACT

BACKGROUND CONTEXT: Total disc arthroplasty is a motion-preserving spinal procedure that has been investigated for its impact on spinal motions and adjacent-level degeneration. However, the effects of disc arthroplasty on facet joint biomechanics remain undefined despite the critical role of these posterior elements on guiding and limiting spinal motion. PURPOSE: The goal was to measure the pressure in the facet joint in cadaveric human cervical spines subjected to sagittal bending before and after implantation of the ProDisc-C (Synthes Spine Company, L.P, West Chester, PA, USA). STUDY DESIGN: A biomechanical study was performed using cadaveric human cervical spines during sagittal bending in the intact and implanted conditions. METHODS: Seven C2-T1 osteoligamentous cadaveric cervical spines were instrumented with a transducer to measure the C5-C6 facet pressure profiles during physiological sagittal bending, before and after implantation of a ProDisc-C at that level. Rotations of the index segment and global cervical spine were also quantified. RESULTS: The mean C5-C6 range of motion significantly increased (p=.009) from 9.6°±5.1° in the intact condition to 16.2°±3.6° after implantation. However, despite such changes in rotation, there was no significant difference in the facet contact pressure during extension between the intact (64±30 kPa) and implanted (44±55 kPa) conditions. Similarly, there was no difference in facet pressure developed during flexion. CONCLUSIONS: Although implantation of a ProDisc-C arthroplasty device at the C5-C6 level increases angular rotations, it does not significantly alter the local facet pressure at the index level in flexion or extension. Using a technique that preserves the capsular ligament, this study provides the first direct measurement of cervical facet pressure in a disc arthroplasty condition.


Subject(s)
Arthroplasty/methods , Cervical Vertebrae/physiology , Intervertebral Disc/surgery , Zygapophyseal Joint/physiology , Biomechanical Phenomena , Cadaver , Humans , Male , Middle Aged , Motion , Pressure , Range of Motion, Articular , Rotation , Stress, Mechanical , Transducers, Pressure
3.
Brain Res ; 1461: 51-63, 2012 Jun 21.
Article in English | MEDLINE | ID: mdl-22578356

ABSTRACT

The cervical facet joint and its capsule are a common source of neck pain from whiplash. Mechanical hyperalgesia elicited by painful facet joint distraction is associated with spinal neuronal hyperexcitability that can be induced by transmitter/receptor systems that potentiate the synaptic activation of neurons. This study investigated the temporal response of a glutamate receptor and transporters in the dorsal root ganglia (DRG) and spinal cord. Bilateral C6/C7 facet joint distractions were imposed in the rat either to produce behavioral sensitivity or without inducing any sensitivity. Neuronal metabotropic glutamate receptor-5 (mGluR5) and protein kinase C-epsilon (PKCε) expression in the DRG and spinal cord were evaluated on days 1 and 7. Spinal expression of a glutamate transporter, excitatory amino acid carrier 1 (EAAC1), was also quantified at both time points. Painful distraction produced immediate behavioral hypersensitivity that was sustained for 7 days. Increased expression of mGluR5 and PKCε in the DRG was not evident until day 7 and only following painful distraction; this increase was observed in small-diameter neurons. Only painful facet joint distraction produced a significant increase (p<0.001) in neuronal mGluR5 over time, and this increase also was significantly elevated (p≤0.05) over responses in the other groups at day 7. However, there were no differences in spinal PKCε expression on either day or between groups. Spinal EAAC1 expression was significantly increased (p<0.03) only in the nonpainful groups on day 7. Results from this study suggest that spinal glutamatergic plasticity is selectively modulated in association with facet-mediated pain.


Subject(s)
Excitatory Amino Acid Transporter 3/biosynthesis , Ganglia, Spinal/metabolism , Receptors, Metabotropic Glutamate/biosynthesis , Spinal Cord/metabolism , Whiplash Injuries/metabolism , Zygapophyseal Joint/metabolism , Animals , Excitatory Amino Acid Transporter 3/physiology , Ganglia, Spinal/pathology , Male , Pain/metabolism , Pain/pathology , Pain Measurement/methods , Protein Kinase C-epsilon/biosynthesis , Rats , Rats, Sprague-Dawley , Receptor, Metabotropic Glutamate 5 , Receptors, Metabotropic Glutamate/physiology , Spinal Cord/pathology , Whiplash Injuries/pathology , Zygapophyseal Joint/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...