Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Geochem Health ; 46(8): 287, 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38970741

ABSTRACT

The aim of the study was an assessment of the pollution level and identification of the antimony sources in soils in areas subjected to industrial anthropopressure from: transport, metallurgy and electrical waste recycling. The combination of soil magnetometry, chemical analyzes using atomic spectrometry (ICP-OES and ICP-MS), Sb fractionation analysis, statistical analysis (Pearson's correlation matrix, factor analysis) as well as Geoaccumulation Index, Pollution Load Index, and Sb/As factor allowed not only the assessment of soil contamination degree, but also comprehensive identification of different Sb sources. The results indicate that the soil in the vicinity of the studied objects was characterized by high values of magnetic susceptibility and thus, high contents of potentially toxic elements. The most polluted area was in the vicinity of electrical waste processing plants. Research has shown that the impact of road traffic and wearing off brake blocks, i.e. traffic anthropopression in general, has little effect on the surrounding soil in terms of antimony content. Large amounts of Pb, Zn, As and Cd were found in the soil collected in the vicinity of the heap after the processing of zinc-lead ores, the average antimony (11.31 mg kg-1) content was lower in the vicinity of the heap than in the area around the electrical and electronic waste processing plant, but still very high. Antimony in the studied soils was demobilized and associated mainly with the residual fraction.


Subject(s)
Antimony , Environmental Monitoring , Soil Pollutants , Soil , Antimony/analysis , Soil Pollutants/analysis , Environmental Monitoring/methods , Soil/chemistry , Spectrophotometry, Atomic/methods , Electronic Waste/analysis , Industrial Waste/analysis
2.
Med Phys ; 51(7): 5099-5108, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38112191

ABSTRACT

BACKGROUND: Superficial targets require the use of the lowest energies within the available energy range in proton pencil-beam scanning (PBS) technique. However, the lower efficiency of the energy selection system at these energies and the requirement of a greater number of layers may represent disadvantages for this approach. The alternative is to use a range shifter (RS) at nozzle exit. However, one of the concerns of using this beamline element is that it becomes an additional source of neutrons that could irradiate organs situated far from the target. PURPOSE: The purpose of this study is to assess the increase in neutron dose due to the RS in proton PBS technique. Additionally, an analytical model for the neutron production is tested. METHODS: Two clinical plans, designed to achieve identical target coverage, were created for an anthropomorphic phantom. These plans consisted of a lateral field delivering an absorbed dose of 60 Gy (RBE) to the target. One of the plans employed the RS. The MCNP code was used to simulate the plans, evaluating the distribution of neutron dose equivalent (Hn) and the equivalent dose in organ. In the plan with the RS plan, neutron production from both the patient and the RS were assessed separately. Hn values were also fitted versus the distance to field edge using a Gaussian function. RESULTS: Hn per prescription dose, in the plan using the RS, ranged between 1.4 and 3.7 mSv/Gy at the field edge, whereas doses at 40 cm from the edge ranged from 9.9 to 32 µSv/Gy. These values are 1.2 to 10 times higher compared to those obtained without the RS. Both this factor and the contribution of neutrons originating from the RS increases with the distance from field edge. A triple-Gaussian function was able to reproduce the equivalent dose in organs within a factor of 2, although underestimating the values. CONCLUSIONS: The dose deposited in the patient by the neutrons originating from the RS predominantly affects areas away from the target (beyond approximately 25 cm from field edge), resulting in a neutron dose equivalent of the order of mSv. This indicates an overall low neutron contribution from the use of RS in PBS.


Subject(s)
Neutrons , Phantoms, Imaging , Proton Therapy , Radiotherapy Dosage , Humans , Proton Therapy/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Monte Carlo Method , Radiation Exposure/analysis , Radiation Dosage
3.
Front Oncol ; 12: 903537, 2022.
Article in English | MEDLINE | ID: mdl-36158693

ABSTRACT

Out-of-field patient doses in proton therapy are dominated by neutrons. Currently, they are not taken into account by treatment planning systems. There is an increasing need to include out-of-field doses in the dose calculation, especially when treating children, pregnant patients, and patients with implants. In response to this demand, this work presents the first steps towards a tool for the prediction of out-of-field neutron doses in pencil beam scanning proton therapy facilities. As a first step, a general Monte Carlo radiation transport model for simulation of out-of-field neutron doses was set up and successfully verified by comparison of simulated and measured ambient neutron dose equivalent and neutron fluence energy spectra around a solid water phantom irradiated with a variation of different treatment plan parameters. Simulations with the verified model enabled a detailed study of the variation of the neutron ambient dose equivalent with field size, range, modulation width, use of a range shifter, and position inside the treatment room. For future work, it is planned to use this verified model to simulate out-of-field neutron doses inside the phantom and to verify the simulation results by comparison with previous in-phantom measurement campaigns. Eventually, these verified simulations will be used to build a library and a corresponding tool to allow assessment of out-of-field neutron doses at pencil beam scanning proton therapy facilities.

4.
Front Oncol ; 12: 882230, 2022.
Article in English | MEDLINE | ID: mdl-35982965

ABSTRACT

Measurements in the stray radiation field from a proton therapy pencil beam at energies 70 and 146 MeV were performed using microdosimetric tissue-equivalent proportional counters (TEPCs). The detector volumes were filled with a propane-based tissue-equivalent gas at low pressure simulating a mean chord length of 2 µm in tissue. Investigations were performed with and without a beam range shifter, and with different air gaps between the range shifter and a solid water phantom. The absorbed dose, the dose-mean lineal energy, and the dose equivalent were determined for different detector positions using the variance-covariance method. The influence from beam energy, detector- and range-shifter positions on absorbed dose, LET, and dose equivalent were investigated. Monte Carlo simulations of the fluence, detector response, and absorbed dose contribution from different particles were performed with MCNP 6.2. The simulated dose response for protons, neutrons, and photons were compared with, and showed good agreement with, previously published experimental data. The simulations also showed that the TEPC absorbed dose agrees well with the ambient absorbed dose for neutron energies above 20 MeV. The results illustrate that changes in both dose and LET variations in the stray radiation field can be identified from TEPC measurements using the variance-covariance method. The results are in line with the changes seen in the simulated relative dose contributions from different particles associated with different proton energies and range-shifter settings. It is shown that the proton contribution scattered directly from the range shifter dominates in some situations, and although the LET of the radiation is decreased, the ambient dose equivalent is increased up to a factor of 3.

5.
Med Phys ; 45(1): 391-401, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29131351

ABSTRACT

PURPOSE: To evaluate the effect on charge collection in the ionization chamber (IC) in proton pencil beam scanning (PBS), where the local dose rate may exceed the dose rates encountered in conventional MV therapy by up to three orders of magnitude. METHODS: We measured values of the ion recombination (ks ) and polarity (kpol ) correction factors in water, for a plane-parallel Markus TM23343 IC, using the cyclotron-based Proteus-235 therapy system with an active proton PBS of energies 30-230 MeV. Values of ks were determined from extrapolation of the saturation curve and the Two-Voltage Method (TVM), for planar fields. We compared our experimental results with those obtained from theoretical calculations. The PBS dose rates were estimated by combining direct IC measurements with results of simulations performed using the FLUKA MC code. Values of ks were also determined by the TVM for uniformly irradiated volumes over different ranges and modulation depths of the proton PBS, with or without range shifter. RESULTS: By measuring charge collection efficiency versus applied IC voltage, we confirmed that, with respect to ion recombination, our proton PBS represents a continuous beam. For a given chamber parameter, e.g., nominal voltage, the value of ks depends on the energy and the dose rate of the proton PBS, reaching c. 0.5% for the TVM, at the dose rate of 13.4 Gy/s. For uniformly irradiated regular volumes, the ks value was significantly smaller, within 0.2% or 0.3% for irradiations with or without range shifter, respectively. Within measurement uncertainty, the average value of kpol , for the Markus TM23343 IC, was close to unity over the whole investigated range of clinical proton beam energies. CONCLUSION: While no polarity effect was observed for the Markus TM23343 IC in our pencil scanning proton beam system, the effect of volume recombination cannot be ignored.


Subject(s)
Proton Therapy , Radiometry/methods , Computer Simulation , Cyclotrons , Monte Carlo Method , Proton Therapy/methods , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...