Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 166
Filter
1.
Opt Express ; 32(12): 21783-21794, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38859524

ABSTRACT

We study the interaction of a laser cavity-soliton microcomb with an externally coupled, co-propagating tunable CW pump, observing parametric Kerr interactions which lead to the formation of both a cross-phase modulation and a four-wave mixing replica of the laser cavity-soliton. We compare and explain the dependence of the microcomb spectra from both the cavity-soliton and pump parameters, demonstrating the ability to adjust the microcomb externally without breaking or interfering with the soliton state. The parametric nature of the process agrees with numerical simulations. The parametric extended state maintains the typical robustness of laser-cavity solitons.

2.
J Am Coll Radiol ; 21(6S): S292-S309, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38823951

ABSTRACT

Sepsis is defined as a life-threatening organ dysfunction caused by a dysregulated host response to infection. A search for the underlying cause of infection typically includes radiological imaging as part of this investigation. This document focuses on thoracic and abdominopelvic causes of sepsis. In 2017, the global incidence of sepsis was estimated to be 48.9 million cases, with 11 million sepsis-related deaths (accounting for nearly 20% of all global deaths); therefore, understanding which imaging modalities and types of studies are acceptable or not acceptable is imperative. The 5 variants provided include the most commonly encountered scenarios in the setting of sepsis along with recommendations and data for each imaging study. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Evidence-Based Medicine , Sepsis , Societies, Medical , Humans , Sepsis/diagnostic imaging , United States , Diagnostic Imaging/standards
5.
Light Sci Appl ; 13(1): 94, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658538

ABSTRACT

Integrated switches play a crucial role in the development of reconfigurable optical add-drop multiplexers (ROADMs) that have greater flexibility and compactness, ultimately leading to robust single-chip solutions. Despite decades of research on switches with various structures and platforms, achieving a balance between dense integration, low insertion loss (IL), and polarization-dependent loss (PDL) remains a significant challenge. In this paper, we propose and demonstrate a 32 × 4 optical switch using high-index doped silica glass (HDSG) for ROADM applications. This switch is designed to route any of the 32 inputs to the express ports or drop any channels from 32 inputs to the target 4 drop ports or add any of the 4 ports to any of the 32 express channels. The switch comprises 188 Mach-Zehnder Interferometer (MZI) type switch elements, 88 optical vias for the 44 optical bridges, and 618 waveguide-waveguide crossings with three-dimensional (3D) structures. At 1550 nm, the fiber-to-fiber loss for each express channel is below 2 dB, and across the C and L bands, below 3 dB. For each input channel to all 4 drop/add channels at 1550 nm, the loss is less than 3.5 dB and less than 5 dB across the C and L bands. The PDLs for all express and input channels to the 4 drop/add channels are below 0.3 dB over the C band, and the crosstalk is under -50 dB for both the C and L bands.

6.
Opt Express ; 32(7): 11281-11295, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38570979

ABSTRACT

We report a dual-polarization radio frequency (RF) channelizer based on microcombs. Two high-Q micro-ring resonators (MRRs) with slightly different free spectral ranges (FSRs) are used: one MRR is pumped to yield soliton crystal microcombs ("active"), and the other MRR is used as a "passive" periodic optical filter supporting dual-polarization operation to slice the RF spectrum. With the tailored mismatch between the FSRs of the active and passive MRRs, wideband RF spectra can be channelized into multiple segments featuring digital-compatible bandwidths via the Vernier effect. Due to the use of dual-polarization states, the number of channelized spectral segments, and thus the RF instantaneous bandwidth (with a certain spectral resolution), can be doubled. In our experiments, we used 20 microcomb lines with ∼ 49 GHz FSR to achieve 20 channels for each polarization, with high RF spectra slicing resolutions at 144 MHz (TE) and 163 MHz (TM), respectively; achieving an instantaneous RF operation bandwidth of 3.1 GHz (TE) and 2.2 GHz (TM). Our approach paves the path towards monolithically integrated photonic RF receivers (the key components - active and passive MRRs are all fabricated on the same platform) with reduced complexity, size, and unprecedented performance, which is important for wide RF applications with digital-compatible signal detection.

7.
Light Sci Appl ; 13(1): 66, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38438369

ABSTRACT

Random bit generators are critical for information security, cryptography, stochastic modeling, and simulations. Speed and scalability are key challenges faced by current physical random bit generation. Herein, we propose a massively parallel scheme for ultrafast random bit generation towards rates of order 100 terabit per second based on a single micro-ring resonator. A modulation-instability-driven chaotic comb in a micro-ring resonator enables the simultaneous generation of hundreds of independent and unbiased random bit streams. A proof-of-concept experiment demonstrates that using our method, random bit streams beyond 2 terabit per second can be successfully generated with only 7 comb lines. This bit rate can be easily enhanced by further increasing the number of comb lines used. Our approach provides a chip-scale solution to random bit generation for secure communication and high-performance computation, and offers superhigh speed and large scalability.

8.
Radiographics ; 44(3): e230057, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38329900

ABSTRACT

Editor's Note.-RadioGraphics Update articles supplement or update information found in full-length articles previously published in RadioGraphics. These updates, written by at least one author of the previous article, provide a brief synopsis that emphasizes important new information such as technological advances, revised imaging protocols, new clinical guidelines involving imaging, or updated classification schemes.


Subject(s)
Early Detection of Cancer , Lung Neoplasms , Humans , Lung Neoplasms/diagnostic imaging , Diagnostic Imaging
10.
Sensors (Basel) ; 23(24)2023 Dec 11.
Article in English | MEDLINE | ID: mdl-38139613

ABSTRACT

The engineering of thermo-optic effects has found broad applications in integrated photonic devices, facilitating efficient light manipulation to achieve various functionalities. Here, we perform both an experimental characterization and a theoretical analysis of these effects in integrated microring resonators made from high-index doped silica, which have had many applications in integrated photonics and nonlinear optics. By fitting the experimental results with theory, we obtain fundamental parameters that characterize their thermo-optic performance, including the thermo-optic coefficient, the efficiency of the optically induced thermo-optic process, and the thermal conductivity. The characteristics of these parameters are compared to those of other materials commonly used for integrated photonic platforms, such as silicon, silicon nitride, and silica. These results offer a comprehensive insight into the thermo-optic properties of doped silica-based devices. Understanding these properties is essential for efficiently controlling and engineering them in many practical applications.

11.
POCUS J ; 8(2): 175-183, 2023.
Article in English | MEDLINE | ID: mdl-38099168

ABSTRACT

Background: Chest imaging, including chest X-ray (CXR) and computed tomography (CT), can be a helpful adjunct to nucleic acid test (NAT) in the diagnosis and management of Coronavirus Disease 2019 (COVID-19). Lung point of care ultrasound (POCUS), particularly with handheld devices, is an imaging alternative that is rapid, highly portable, and more accessible in low-resource settings. A standardized POCUS scanning protocol has been proposed to assess the severity of COVID-19 pneumonia, but it has not been sufficiently validated to assess diagnostic accuracy for COVID-19 pneumonia. Purpose: To assess the diagnostic performance of a standardized lung POCUS protocol using a handheld POCUS device to detect patients with either a positive NAT or a COVID-19-typical pattern on CT scan. Methods: Adult inpatients with confirmed or suspected COVID-19 and a recent CT were recruited from April to July 2020. Twelve lung zones were scanned with a handheld POCUS machine. Images were reviewed independently by blinded experts and scored according to the proposed protocol. Patients were divided into low, intermediate, and high suspicion based on their POCUS score. Results: Of 79 subjects, 26.6% had a positive NAT and 31.6% had a typical CT pattern. The receiver operator curve for POCUS had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for a typical CT. Using a two-point cutoff system, POCUS had a sensitivity of 0.90 and 1.00 compared to NAT and typical CT pattern, respectively, at the lower cutoff; it had a specificity of 0.90 and 0.89 compared to NAT and typical CT pattern at the higher cutoff, respectively. Conclusions: The proposed lung POCUS protocol with a handheld device showed reasonable diagnostic performance to detect inpatients with a positive NAT or typical CT pattern for COVID-19. Particularly in low-resource settings, POCUS with handheld devices may serve as a helpful adjunct for persons under investigation for COVID-19 pneumonia.

12.
Opt Express ; 31(23): 37749-37762, 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-38017898

ABSTRACT

Soliton crystals are a novel form of microcomb, with relatively high conversion efficiency, good thermal robustness, and simple initiation among the methods to generate them. Soliton crystals can be easily generated in microring resonators with an appropriate mode-crossing. However, fabrication defects can significantly affect the mode-crossing placement and strength in devices. To enable soliton crystal states to be harnessed for a broader range of microcomb applications, we need a better understanding of the link between mode-crossing properties and the desired soliton crystal properties. Here, we investigate how to generate the same soliton crystal state in two different microrings, how changes in microring temperature change the mode-crossing properties, and how mode-crossing properties affect the generation of our desired soliton crystal state. We find that temperature affects the mode-crossing position in these rings but without major changes in the mode-crossing strength. We find that our wanted state can be generated over a device temperature range of 25 ∘C, with different mode-crossing properties, and is insensitive to the precise mode-crossing position between resonances.

13.
Clin Lung Cancer ; 24(8): 682-688.e5, 2023 12.
Article in English | MEDLINE | ID: mdl-37758549

ABSTRACT

INTRODUCTION/BACKGROUND: Immune-related pneumonitis is a potentially fatal complication of treatment with immune checkpoint inhibitors (ICIs). Interstitial lung disease (ILD) is associated with increased risk for pneumonitis, but the impact of interstitial abnormalities (ILA) in the absence of ILD has not been extensively assessed. We examined the relationship between ILA on pretreatment chest computed tomography (CT) scans and risk of pneumonitis in patients with non-small-cell lung cancer (NSCLC). METHODS: This retrospective cohort study included consecutive adult patients who received ICI for NSCLC between January 2013 and January 2020 at our institution. Two thoracic radiologists blinded to clinical outcomes independently reviewed pre-ICI chest CTs to identify and categorize ILA using previously published definitions. We used uni- and multivariable analysis adjusted for age, radiation, and smoking status to assess for associations between ILA, clinicopathologic characteristics, and symptomatic (CTCAE grade ≥2) pneumonitis. RESULTS: Of 475 patients who received ICI treatment and met inclusion criteria, baseline ILA were present in 78 (16.4%) patients, most commonly as a subpleural nonfibrotic pattern. In total, 43 (9.1%) of 475 patients developed symptomatic pneumonitis. Pneumonitis occurred in 16.7% of patients with ILA compared to 7.6% patients without ILA (P < .05). Presence of ground glass and extent of lung parenchymal involvement were associated with an increased risk of pneumonitis. On multivariable analysis, baseline ILA remained associated with increased risk of symptomatic pneumonitis (OR 2.2, 95% CI, 1.0-4.5). CONCLUSIONS: Baseline ILAs are associated with the development of symptomatic pneumonitis in patients with NSCLC treated with ICI. Additional studies are needed to validate these observations.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Diseases, Interstitial , Lung Neoplasms , Pneumonia , Adult , Humans , Carcinoma, Non-Small-Cell Lung/pathology , Immune Checkpoint Inhibitors/adverse effects , Lung Neoplasms/pathology , Retrospective Studies , Lung/pathology , Pneumonia/chemically induced , Lung Diseases, Interstitial/chemically induced , Lung Diseases, Interstitial/complications
14.
Appl Opt ; 62(14): 3772-3777, 2023 May 10.
Article in English | MEDLINE | ID: mdl-37706995

ABSTRACT

Integrated narrow-linewidth lasers are the key devices in compact coherent optical systems of metrology, sensing, and optical microwave generation. Here, we demonstrate a hybrid integrated laser based on an optical negative feedback scheme. The laser is composed of a commercial distributed feedback (DFB) laser diode and an on-chip micro-resonator with a Q-factor of 0.815 million. The feedback optical field is coupled back to the laser cavity through the back facet. Therefore, the laser can maintain the lasing efficiency of the DFB laser diode. The linewidth of the DFB laser diode is compressed from 2 MHz to 6 kHz, corresponding to the linewidth reduction factor of 25.2 dB. The theoretical result shows that the laser performance still has a huge improvement margin through precise control of the detuning between laser frequency and the micro-resonator, as well as the phase delay of the feedback optical field. The hybrid narrow-linewidth laser diode has wide application prospects in coherent optical systems benefitting from the low cost and volume productivity.

16.
J Am Coll Radiol ; 20(11): 1126-1130, 2023 11.
Article in English | MEDLINE | ID: mdl-37392983

ABSTRACT

Users of artificial intelligence (AI) can become overreliant on AI, negatively affecting the performance of human-AI teams. For a future in which radiologists use interpretive AI tools routinely in clinical practice, radiology education will need to evolve to provide radiologists with the skills to use AI appropriately and wisely. In this work, we examine how overreliance on AI may develop in radiology trainees and explore how this problem can be mitigated, including through the use of AI-augmented education. Radiology trainees will still need to develop the perceptual skills and mastery of knowledge fundamental to radiology to use AI safely. We propose a framework for radiology trainees to use AI tools with appropriate reliance, drawing on lessons from human-AI interactions research.


Subject(s)
Artificial Intelligence , Radiology , Humans , Radiology/education , Radiologists , Forecasting
17.
J Am Coll Radiol ; 20(5S): S224-S233, 2023 05.
Article in English | MEDLINE | ID: mdl-37236745

ABSTRACT

Routine chest imaging has been used to identify unknown or subclinical cardiothoracic abnormalities in the absence of symptoms. Various imaging modalities have been suggested for routine chest imaging. We review the evidence for or against the use of routine chest imaging in different clinical scenarios. This document aims to determine guidelines for the use of routine chest imaging as initial imaging for hospital admission, initial imaging prior to noncardiothoracic surgery, and surveillance imaging for chronic cardiopulmonary disease. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Diagnostic Imaging , Societies, Medical , Humans , United States , Diagnostic Imaging/methods
18.
Opt Express ; 31(6): 10525-10532, 2023 Mar 13.
Article in English | MEDLINE | ID: mdl-37157597

ABSTRACT

Silicon nitride (SiN) integrated optical waveguides have found a wide range of applications due to their low loss, broad wavelength transmission band and high nonlinearity. However, the large mode mismatch between the single-mode fiber and the SiN waveguide creates a challenge of fiber coupling to these waveguides. Here, we propose a coupling approach between fiber and SiN waveguides by utilizing the high-index doped silica glass (HDSG) waveguide as the intermediary to smooth out the mode transition. We achieved fiber-to-SiN waveguide coupling efficiency of lower than 0.8 dB/facet across the full C and L bands with high fabrication and alignment tolerances.

19.
Mayo Clin Proc Innov Qual Outcomes ; 7(3): 143-152, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37020901

ABSTRACT

Objective: To investigate the performance of a commercially available artificial intelligence (AI) algorithm for the detection of pulmonary embolism (PE) on contrast-enhanced computed tomography (CT) scans in patients hospitalized for coronavirus disease 2019 (COVID-19). Patients and Methods: Retrospective analysis was performed of all contrast-enhanced chest CT scans of patients admitted for COVID-19 between March 1, 2020 and December 31, 2021. Based on the original radiology reports, all PE-positive examinations were included (n=527). Using a reversed-flow single-gate diagnostic accuracy case-control model, a randomly selected cohort of PE-negative examinations (n=977) was included. Pulmonary parenchymal disease severity was assessed for all the included studies using a semiquantitative system, the total severity score. All included CT scans were sent for interpretation by the commercially available AI algorithm, Aidoc. Discrepancies between AI and original radiology reports were resolved by 3 blinded radiologists, who rendered a final determination of indeterminate, positive, or negative. Results: A total of 78 studies were found to be discrepant, of which 13 (16.6%) were deemed indeterminate by readers and were excluded. The sensitivity and specificity of AI were 93.2% (95% CI, 90.6%-95.2%) and 99.6% (95% CI, 98.9%-99.9%), respectively. The accuracy of AI for all total severity score groups (mild, moderate, and severe) was high (98.4%, 96.7%, and 97.2%, respectively). Artificial intelligence was more accurate in PE detection on CT pulmonary angiography scans than on contrast-enhanced CT scans (P<.001), with an optimal Hounsfield unit of 362 (P=.048). Conclusion: The AI algorithm demonstrated high sensitivity, specificity, and accuracy for PE on contrast-enhanced CT scans in patients with COVID-19 regardless of parenchymal disease. Accuracy was significantly affected by the mean attenuation of the pulmonary vasculature. How this affects the legitimacy of the binary outcomes reported by AI is not yet known.

20.
AJR Am J Roentgenol ; 221(2): 258-271, 2023 08.
Article in English | MEDLINE | ID: mdl-36919884

ABSTRACT

BACKGROUND. Newspapers are an important source of information for the public about low-dose CT (LDCT) lung cancer screening (LCS) and may influence public perception and knowledge of this important cancer screening service. OBJECTIVE. The purpose of this article was to evaluate the volume, content, and other characteristics of articles pertaining to LCS that have been published in U.S. newspapers. METHODS. The ProQuest U.S. Newsstream database was searched for U.S. newspaper articles referring to LCS published between January 1, 2010 (the year of publication of the National Lung Screening Trial results), and March 28, 2022. Search terms included "lung cancer screening(s)," "lung screening(s)," "low dose screening(s)," and "LDCT." Search results were reviewed to identify those articles mentioning LCS. Characteristics of included articles and originating newspapers were extracted. Articles were divided among nine readers, who independently assessed article sentiment regarding LCS and additional article content using a standardized form. RESULTS. The final analysis included 859 articles, comprising 816 nonsyndicated articles published in a single newspaper and 43 syndicated articles published in multiple newspapers. Sentiment regarding LCS was positive in 76% (651/859) of articles, neutral in 21% (184/859), and negative in 3% (24/859). Frequency of positive sentiment was lowest (61%) for articles published from 2010 to 2012; frequency of negative sentiment was highest (8%) for articles published in newspapers in the highest quartile for weekly circulation. LCS enrollment criteria were mentioned in 52% of articles, smoking cessation programs in 28%, need for annual CT in 27%, and shared decision-making in 4%. Cost or insurance coverage for LCS was mentioned in 33% in articles. A total of 64% of articles mentioned at least one benefit of LCS (most commonly early detection or possible cure of lung cancer), and 23% mentioned at least one harm (most commonly false-positives). A total of 9% of articles interviewed or mentioned a radiologist. CONCLUSION. The sentiment of U.S. newspaper articles covering LCS from 2010 to 2022 was overall positive. However, certain key elements of LCS were infrequently mentioned. CLINICAL IMPACT. The findings highlight areas for potential improvement of LCS media coverage; radiologists have an opportunity to take a more active role in this coverage.


Subject(s)
Lung Neoplasms , Humans , Lung Neoplasms/diagnostic imaging , Early Detection of Cancer
SELECTION OF CITATIONS
SEARCH DETAIL
...