Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Nanotechnology ; 31(42): 424002, 2020 Jun 24.
Article in English | MEDLINE | ID: mdl-32580185

ABSTRACT

Lateral piezoresponse force microscopy (L-PFM) is demonstrated as a reliable method for determining the crystallographic polarity of individual, dispersed GaN nanowires that were functional components in electrical test structures. In contrast to PFM measurements of vertically oriented (as-grown) nanowires, where a biased probe tip couples to out-of-plane deformations through the d33 piezoelectic coefficient, the L-PFM measurements in this study were implemented on horizontally oriented nanowires that coupled to shear deformations through the d15 coefficient. L-PFM phase-polarity relationships were determined experimentally using a bulk m-plane GaN sample with a known [0001] direction and further indicated that the sign of the d15 piezoelectric coefficient was negative. L-PFM phase images successfully revealed the in-plane [0001] orientation of self-assembed GaN nanowires as part of a growth polarity study and results were validated against scanning transmission electron microscopy lattice images. Combined characterization of electrical properties and crystallographic polarity was also implemented for two-terminal GaN/Al0.1Ga0.9N/GaN nanowires devices, demonstrating L-PFM measurements as a viable tool for assessing correlations between device rectification and polarization-induced band bending.

2.
Nat Commun ; 10(1): 1174, 2019 03 12.
Article in English | MEDLINE | ID: mdl-30862776

ABSTRACT

Detection of conformational changes in biomolecular assemblies provides critical information into biological and self-assembly processes. State-of-the-art in situ biomolecular conformation detection techniques rely on fluorescent labels or protein-specific binding agents to signal conformational changes. Here, we present an on-chip, label-free technique to detect conformational changes in a DNA nanomechanical tweezer structure with microwave microfluidics. We measure the electromagnetic properties of suspended DNA tweezer solutions from 50 kHz to 110 GHz and directly detect two distinct conformations of the structures. We develop a physical model to describe the electrical properties of the tweezers, and correlate model parameters to conformational changes. The strongest indicator for conformational changes in DNA tweezers are the ionic conductivity, while shifts in the magnitude of the cooperative water relaxation indicate the addition of fuel strands used to open the tweezer. Microwave microfluidic detection of conformational changes is a generalizable, non-destructive technique, making it attractive for high-throughput measurements.


Subject(s)
DNA/chemistry , Lab-On-A-Chip Devices , Microfluidics/instrumentation , Nanostructures/chemistry , Nucleic Acid Conformation , High-Throughput Screening Assays/instrumentation , High-Throughput Screening Assays/methods , Microfluidics/methods , Microwaves , Models, Chemical
3.
Phys Rev Fluids ; 2(3)2017 Mar.
Article in English | MEDLINE | ID: mdl-28691108

ABSTRACT

Non-Newtonian fluids are susceptible to flow instabilities such as shear banding, in which the fluid may exhibit a markedly discontinuous viscosity at a critical stress. Here we report the characteristics and causes of a jetting flow instability of shear banding wormlike micelle solutions in microfluidic channels with rectangular cross sections over an intermediate volumetric flow regime. Particle-tracking methods are used to measure the three-dimensional flow field in channels of differing aspect ratios, sizes, and wall materials. When jetting occurs, it is self-contained within a portion of the channel where the flow velocity is greater than the surroundings. We observe that the instability forms in channels with aspect ratio greater than 5, and that the location of the high-velocity jet appears to be sensitive to stress localizations. Jetting is not observed in a lower concentration solution without shear banding. Simulations using the Johnson-Segalman viscoelastic model show a qualitatively similar behavior to the experimental observations and indicate that compressive normal stresses in the cross-stream directions support the development of the jetting flow. Our results show that nonuniform flow of shear thinning fluids can develop across the wide dimension in rectangular microfluidic channels, with implications for microfluidic rheometry.

4.
Lab Chip ; 17(15): 2674-2681, 2017 07 25.
Article in English | MEDLINE | ID: mdl-28702651

ABSTRACT

Broadband microfluidic-based impedance spectroscopy can be used to characterize complex fluids, with applications in medical diagnostics and in chemical and pharmacological manufacturing. Many relevant fluids are ionic; during impedance measurements ions migrate to the electrodes, forming an electrical double-layer. Effects from the electrical double-layer dominate over, and reduce sensitivity to, the intrinsic impedance of the fluid below a characteristic frequency. Here we use calibrated measurements of saline solution in microfluidic coplanar waveguide devices at frequencies between 100 kHz and 110 GHz to directly measure the double-layer admittance for solutions of varying ionic conductivity. We successfully model the double-layer admittance using a combination of a Cole-Cole response with a constant phase element contribution. Our analysis yields a double-layer relaxation time that decreases linearly with solution conductivity, and allows for double-layer effects to be separated from the intrinsic fluid response and quantified for a wide range of conducting fluids.

SELECTION OF CITATIONS
SEARCH DETAIL
...