Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomed Opt ; 22(8): 1-10, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28825287

ABSTRACT

According to the International Diabetes Federation, the challenge of early stage diagnosis and treatment effectiveness monitoring in diabetes is currently one of the highest priorities in modern healthcare. The potential of combined measurements of skin fluorescence and blood perfusion by the laser Doppler flowmetry method in diagnostics of low limb diabetes complications was evaluated. Using Monte Carlo probabilistic modeling, the diagnostic volume and depth of the diagnosis were evaluated. The experimental study involved 76 patients with type 2 diabetes mellitus. These patients were divided into two groups depending on the degree of complications. The control group consisted of 48 healthy volunteers. The local thermal stimulation was selected as a stimulus on the blood microcirculation system. The experimental studies have shown that diabetic patients have elevated values of normalized fluorescence amplitudes, as well as a lower perfusion response to local heating. In the group of people with diabetes with trophic ulcers, these parameters also significantly differ from the control and diabetes only groups. Thus, the intensity of skin fluorescence and level of tissue blood perfusion can act as markers for various degrees of complications from the beginning of diabetes to the formation of trophic ulcers.


Subject(s)
Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/physiopathology , Lower Extremity/blood supply , Tissue Survival/physiology , Case-Control Studies , Female , Fluorescence , Humans , Laser-Doppler Flowmetry , Male , Microcirculation/physiology , Middle Aged , Skin/blood supply
2.
J Biomed Opt ; 21(2): 25006, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26882448

ABSTRACT

Urinary bladder diseases are a common problem throughout the world and often difficult to accurately diagnose. Furthermore, they pose a heavy financial burden on health services. Urinary bladder tissue from male pigs was spectrophotometrically measured and the resulting data used to calculate the absorption, transmission, and reflectance parameters, along with the derived coefficients of scattering and absorption. These were employed to create a "generic" computational bladder model based on optical properties, simulating the propagation of photons through the tissue at different wavelengths. Using the Monte-Carlo method and fluorescence spectra of UV and blue excited wavelength, diagnostically important biomarkers were modeled. Additionally, the multifunctional noninvasive diagnostics system "LAKK-M" was used to gather fluorescence data to further provide essential comparisons. The ultimate goal of the study was to successfully simulate the effects of varying excited radiation wavelengths on bladder tissue to determine the effectiveness of photonics diagnostic devices. With increased accuracy, this model could be used to reliably aid in differentiating healthy and pathological tissues within the bladder and potentially other hollow organs.


Subject(s)
Computer Simulation , Models, Biological , Optical Imaging/methods , Urinary Bladder/anatomy & histology , Urinary Bladder/physiology , Animals , Imaging, Three-Dimensional , Male , Monte Carlo Method , Swine
3.
Med Eng Phys ; 37(6): 574-83, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25922293

ABSTRACT

Fluorescence spectroscopy has recently become more common in clinical medicine. However, there are still many unresolved issues related to the methodology and implementation of instruments with this technology. In this study, we aimed to assess individual variability of fluorescence parameters of endogenous markers (NADH, FAD, etc.) measured by fluorescent spectroscopy (FS) in situ and to analyse the factors that lead to a significant scatter of results. Most studied fluorophores have an acceptable scatter of values (mostly up to 30%) for diagnostic purposes. Here we provide evidence that the level of blood volume in tissue impacts FS data with a significant inverse correlation. The distribution function of the fluorescence intensity and the fluorescent contrast coefficient values are a function of the normal distribution for most of the studied fluorophores and the redox ratio. The effects of various physiological (different content of skin melanin) and technical (characteristics of optical filters) factors on the measurement results were additionally studied. The data on the variability of the measurement results in FS should be considered when interpreting the diagnostic parameters, as well as when developing new algorithms for data processing and FS devices.


Subject(s)
Skin/metabolism , Spectrometry, Fluorescence/methods , Adult , Asian People , Black People , Blood Volume/physiology , Computer Simulation , Female , Fingers/blood supply , Forearm/blood supply , Humans , Lasers , Male , Melanins/metabolism , Models, Theoretical , Monte Carlo Method , Skin/blood supply , White People , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...