Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Biosens Bioelectron ; 237: 115448, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37348190

ABSTRACT

Transistor-based biosensors represent an emerging technology for inexpensive point-of-care testing (POCT) applications. However, the limited sensitivity of the current transistor technologies hinders their practical deployment. In this study, we developed tri-channel In2O3/ZnO heterojunction thin-film transistors (TFTs) featuring the surface-immobilized enzyme glucose oxidase to detect glucose in various biofluids. This unusual channel design facilitates strong coupling between the electrons transported along the buried In2O3/ZnO heterointerface and the electrostatic perturbations caused by the interactions between glucose and surface-immobilized glucose oxidase. The enzyme selectively binds to glucose, causing a change in charge density on the channel surface. By exploring this effect, the solid-state biosensing TFT (BioTFT) can selectively detect glucose in artificial and real saliva over a wide range of concentrations from 500 nM to 20 mM with limits of detection of ∼365 pM (artificial saliva) and ∼416 nM (real saliva) in less than 60 s. The specificity of the sensor towards glucose has been demonstrated against various interfering species in artificial saliva, further highlighting its unique capabilities. Moreover, the BioTFTs exhibited good operating stability upon storage for up to two weeks, with relative standard deviation (RSD) values ranging from 2.36% to 6.39% for 500 nM glucose concentration. Our BioTFTs are easy to manufacture with reliable operation, making them ideal for non-invasive POCT applications.


Subject(s)
Biosensing Techniques , Zinc Oxide , Glucose , Saliva , Transistors, Electronic , Saliva, Artificial , Glucose Oxidase , Oxides
2.
Adv Mater ; 34(3): e2104608, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34738258

ABSTRACT

Solid-state transistor sensors that can detect biomolecules in real time are highly attractive for emerging bioanalytical applications. However, combining upscalable manufacturing with the required performance remains challenging. Here, an alternative biosensor transistor concept is developed, which relies on a solution-processed In2 O3 /ZnO semiconducting heterojunction featuring a geometrically engineered tri-channel architecture for the rapid, real-time detection of important biomolecules. The sensor combines a high electron mobility channel, attributed to the electronic properties of the In2 O3 /ZnO heterointerface, in close proximity to a sensing surface featuring tethered analyte receptors. The unusual tri-channel design enables strong coupling between the buried electron channel and electrostatic perturbations occurring during receptor-analyte interactions allowing for robust, real-time detection of biomolecules down to attomolar (am) concentrations. The experimental findings are corroborated by extensive device simulations, highlighting the unique advantages of the heterojunction tri-channel design. By functionalizing the surface of the geometrically engineered channel with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody receptors, real-time detection of the SARS-CoV-2 spike S1 protein down to am concentrations is demonstrated in under 2 min in physiological relevant conditions.


Subject(s)
Biosensing Techniques/instrumentation , COVID-19/virology , SARS-CoV-2/chemistry , Spike Glycoprotein, Coronavirus/analysis , Transistors, Electronic , Angiotensin-Converting Enzyme 2/metabolism , Antibodies, Immobilized , Antibodies, Viral , Bioengineering , COVID-19/blood , COVID-19/diagnosis , COVID-19 Testing/instrumentation , COVID-19 Testing/methods , Computer Simulation , Computer Systems , DNA/analysis , Equipment Design , Humans , Indium , Microtechnology , Proof of Concept Study , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/metabolism , Zinc Oxide
3.
Tzu Chi Med J ; 33(1): 42-48, 2021.
Article in English | MEDLINE | ID: mdl-33505877

ABSTRACT

OBJECTIVE: Conventional cochlear implants provide patients who are deaf with hearing via electrical intracochlear stimulations. Stimulation electrodes are inserted into the cochlea through a cochleostomy or round window membrane (RWM) approach. However, these methods might induce cochlear ossificans and loss of residual hearing by damaging inner ear structures. To avoid an invasive electrode insertion, we developed a novel bone-guided extracochlear implant that stimulated the auditory nerves between the cochlear bones and the RWM to prevent cochlea damage. Power consumption plays an important role in wireless implantable electronic devices. Therefore, we aimed to investigate the effects of different electrodes on the stimulating threshold currents of the auditory nerve and the power consumption of bone-guided extracochlear implants using a commercial stimulator. MATERIALS AND METHODS: Inert aurum (Au) electrodes were compared with biocompatible platinum (Pt) and iridium oxide (IrOx) electrodes in practical implantable applications. IrOx electrodes were used for their high-charge storage capacity, low impedance, and biocompatibility. The electrodes were fabricated via sputtering and were experimentally characterized with cyclic voltammetry and then examined using in vivo tests. RESULTS: Based on electrical auditory brainstem responses, IrOx electrodes yielded lower acoustic nerve-stimulating threshold currents (132 µA) compared with Au electrodes (204 µA). IrOx electrodes also had a lower acoustic nerve stimulating threshold current (132 µA) compared with Pt electrodes (168 µA). CONCLUSION: As expected, IrOx electrodes were beneficial in the development of multielectrode bone-guided extracochlear implants, with the lowest acoustic nerve-stimulating threshold and current consumptions compared with Au and Pt electrodes.

4.
Appl Bionics Biomech ; 2020: 5927657, 2020.
Article in English | MEDLINE | ID: mdl-32765645

ABSTRACT

In this research, we proposed a lower-limb soft exoskeleton for providing assistive forces to patients with muscle weakness during the preswing phase of a gait cycle. Whereas conventional soft exoskeletons employ two motors to assist each leg individually, we designed a single motor for actuation. Our design assists hip flexion for light weights and prevents some slip problems that can arise from rotary motors. The actuation mechanism was based on a pulley system that converted the power supplied by the single motor into linear reciprocating motions of a slider. When the single motor rotated, the slider moved linearly, first in one direction and then in the opposite direction. The slider pulled knee braces through cables with an assistive force of 100 N. The actuation was triggered when the system detected that the backward swing of the wearer's thigh had ended. A prototype was designed, fabricated, and examined with 7 subjects (average age, 24). Subjects were measured while they wore our exoskeleton in power-off and power-on modes. Comparisons proved that wearing the exoskeleton caused a negligible deviation of gait, and that the soft exoskeleton could reduce metabolic cost during walking. The research results are expected to be beneficial for lightweight soft exoskeletons and integration with exosuits that provide assistive forces through the wearer's entire gait.

5.
Sensors (Basel) ; 19(21)2019 Oct 23.
Article in English | MEDLINE | ID: mdl-31652844

ABSTRACT

Recently, smart stents have been developed by integrating various sensors with intravascular stents for detecting vascular restenosis or monitoring intravascular biomedical conditions such as blood pressure or blood flow velocity. The information on biomedical signals is then transmitted to external monitoring systems via wireless communications. Due to the limited volumes of blood vessels and limited influence of blood flow, antennas with good radiation performance are required for intravascular applications. In this paper, we propose a stent antenna composed of multiple rings containing crowns and struts, where each ring is connected with one connector. Unlike a conventional stent, wherein each ring is connected with several connectors, the single connector prevents the random distribution of electrical current and thus achieves good radiation performance. The implantable stent antenna is designed for the frequency range of 2 to 3 GHz for minimum penetration loss in the human body and tissues. Mechanical FEM simulations were conducted to ensure that the mechanical deformation was within specific limits during balloon expansions. A prototype was fabricated with laser cutting techniques and its radiation performance experimentally characterized. It was demonstrated that the fabricated stent antenna had an omnidirectional radiation pattern for arbitrary receiving angles, a gain of 1.38 dBi, and a radiation efficiency of 74.5% at a resonant frequency of 2.07 GHz. The main contribution of this work was the manipulation of the current distributions of the stent for good EM radiation performances which needed to be further examined while inserted inside human bodies. These research results should contribute to the further development of implantable wireless communications and intravascular monitoring of biomedical signals such as blood pressure and blood flow velocity.

6.
Sensors (Basel) ; 19(16)2019 Aug 08.
Article in English | MEDLINE | ID: mdl-31398945

ABSTRACT

In this research, we proposed a miniaturized two-element sensor array inspired by Ormia Ochracea for sound direction finding applications. In contrast to the convectional approach of using mechanical coupling structures for enlarging the intensity differences, we exploited an electrical coupling network circuit composed of lumped elements to enhance the phase differences and extract the optimized output power for good signal-to-noise ratio. The separation distance between two sensors could be reduced from 0.5 wavelength to 0.1 wavelength 3.43 mm at the operation frequency of 10 kHz) for determining the angle of arrivals. The main advantages of the proposed device include low power losses, flexible designs, and wide operation bandwidths. A prototype was designed, fabricated, and experiments examined within a sound anechoic chamber. It was demonstrated that the proposed device had a phase enhancement of 110 ∘ at the incident angle of 90 ∘ and the normalized power level of -2.16 dB at both output ports. The received power levels of our device were 3 dB higher than those of the transformer-type direction-finding system. In addition, our proposed device could operate in the frequency range from 8 kHz to 12 kHz with a tunable capacitor. The research results are expected to be beneficial for the compact sonar or radar systems.

7.
Polymers (Basel) ; 11(1)2019 Jan 15.
Article in English | MEDLINE | ID: mdl-30960125

ABSTRACT

In recent years, dielectric elastomer actuators (DEAs) have attracted lots of attention for providing multiple degree-of-freedom motions, such as axial extensions, torsion, bending, and their combinations. The wide applications include soft robots, artificial muscles, and biomimetic animals. In general, DEAs are composed of stretchable elastomers sandwiched by two compliant electrodes and actuated by applying external electric stimuli. Since most DEAs are limited by the breakdown thresholds and low strain-to-volume ratios, dielectric fluid transducers (DFTs) have been developed by substituting dielectric elastomers with dielectric fluids for high breakdown threshold voltages. In addition, DFTs have large rate of lateral extensions, due to their fluid contents, and are beneficial for soft actuators and pumping applications. In this research, we exploited DFTs to develop a soft spiral proboscis actuator inspired by the proboscises of butterflies for achieving uncoiling and coiling motions under external voltages. The bio-inspired spiral proboscis actuator (BSPA) was composed of a coil-shaped tube, a DFT-based pouch, and a spiral spring for mimicking the tubular part, a mechanism to uncoil the tube, and a mechanism to coil the tube, respectively. When applying external voltages to the pouch, the high dielectric fluid was injected into the empty coiled tube for uncoiling where the tube elongated from a compact volume to a stiff and flexible shape. When removing the exciting voltages, the tube retracted to its original coiled shape via the elastic spring. A prototype was designed, fabricated, and examined with high stimulating voltages. It was demonstrated that the proboscis actuator could achieve uncoiling and coiling motions consistently for several cycles. Compared to convection DEA-based pumps with fixed shapes, the proposed actuator is soft and beneficial for portable applications and coiling/uncoiling motions.

8.
IEEE Trans Biomed Eng ; 66(11): 3156-3167, 2019 11.
Article in English | MEDLINE | ID: mdl-30802846

ABSTRACT

OBJECTIVE: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem with electrodes placed on the bone surface of the cochlea and the outside of round window for treating high-frequency hearing loss. METHODS: The BGCI microsystem consists of an external unit and an implanted unit. The external system-on-chip is designed to process acoustic signals through an acquisition circuit and an acoustic DSP processor to generate stimulation patterns and commands that are transmitted to the implanted unit through a 13.56 MHz wireless power and bidirectional data telemetry. In the wireless power telemetry, a voltage doubler/tripler (2X/3X) active rectifier is used to enhance the power conversion efficiency and generate 2 and 3 V output voltages. In the wireless data telemetry, phase-locked loop based binary phase-shift keying and load-shift keying modulators/demodulators are adopted for the downlink and uplink data through high-Q coils, respectively. The implanted chip with four-channel high-voltage-tolerant stimulator generates biphasic stimulation currents up to 800 µA. RESULTS: Electrical tests on the fabricated BGCI microsystem have been performed to verify the chip functions. The in vivo animal tests in guinea pigs have shown the evoked third wave of electrically evoked auditory brainstem response waveforms. It is verified that auditory nerves can be successfully stimulated and acoustic hearing can be partially preserved. CONCLUSION AND SIGNIFICANCE: Different from traditional cochlear implants, the proposed BGCI microsystem is less invasive, preserves partially acoustic hearing, and provides an effective alternative for treating high-frequency hearing loss.


Subject(s)
Cochlear Implantation/instrumentation , Cochlear Implants , Microtechnology/instrumentation , Animals , Cochlea/physiology , Cochlea/surgery , Cochlear Nerve/physiology , Equipment Design , Guinea Pigs , Humans , Semiconductors
9.
Micromachines (Basel) ; 11(1)2019 Dec 30.
Article in English | MEDLINE | ID: mdl-31905859

ABSTRACT

With the rapid developments of the Industrial Era 4.0, numerous sensors have been employed to facilitate and monitor the quality of machining processes. Among them, accelerometers play an important role in chatter detection and suppression for reducing the tool down-time and increasing manufacturing efficiency. To date, most commonly seen accelerometers have relatively large sizes such that they can be installed only on the housing of spindles or the surfaces of workpieces that may not be able to directly capture actual vibration signals or obstruct the cutting process. To address this challenge, this research proposed a compact, wide-bandwidth resonant accelerometer that could be embedded inside high-speed spindles for real-time chatter monitoring and prediction. Composed of a double-ended tuning fork (DETF), a proof mass, and a support beam, the resonant accelerometer utilizes the resonance frequency shift of the DETF due to the bending motions of the structure during out-of-plane accelerations as the sensing mechanism. The entire structure based on commercially available quartz tuning forks (QTFs) with electrodes for symmetric-mode excitations. The advantages of this structure include low noise and wide operation bandwidth thanks to the frequency modulation scheme. A theoretical model and finite element analysis were conducted for designs and optimizations. Simulated results demonstrated that the proposed accelerometer has a size of 9.76 mm × 4.8 mm × 5.5 mm, a simulated sensitivity of 0.94 Hz/g, and a simulated working bandwidth of 3.5 kHz. The research results are expected to be beneficial for chatter detection and intelligent manufacturing.

10.
Micromachines (Basel) ; 8(11)2017 Nov 22.
Article in English | MEDLINE | ID: mdl-30400528

ABSTRACT

In recent years, dielectric elastomer actuators (DEAs) have been widely used in soft robots and artificial bio-medical applications. Most DEAs are composed of a thin dielectric elastomer layer sandwiched between two compliant electrodes. DEAs vary in their design to provide bending, torsional, and stretch/contraction motions under the application of high external voltages. Most compliant electrodes are made of carbon powders or thin metallic films. In situations involving large deformations or improper fabrication, the electrodes are susceptible to breakage and increased resistivity. The worst cases result in a loss of conductivity and functional failure. In this study, we developed a method by which to exploit stretchable metallic springs as compliant electrodes for cylindrical DEAs. This design was inspired by the extensibility of mechanical springs. The main advantage of this approach is the fact that the metallic spring-like compliant electrodes remain conductive and do not increase the stiffness as the tube-like DEAs elongate in the axial direction. This can be attributed to a reduction in thickness in the radial direction. The proposed cylindrical structure is composed of highly-stretchable VHB 4905 film folded within a hollow tube and then sandwiched between copper springs (inside and outside) to allow for stretching and contraction in the axial direction under the application of high DC voltages. We fabricated a prototype and evaluated the mechanical and electromechanical properties of the device experimentally using a high-voltage source of 9.9 kV. This device demonstrated a non-linear increase in axial stretching with an increase in applied voltage, reaching a maximum extension of 0.63 mm (axial strain of 2.35%) at applied voltage of 9.9 kV. Further miniaturization and the incorporation of compressive springs are expected to allow the implementation of the proposed method in soft micro-robots and bio-mimetic applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...